background image

Lenovo System x3650 M5 (E5-2600 v4)

Product Guide

With the powerful, versatile 2U rack server design, the dual-socket Lenovo System x3650 M5 (E5-2600 v4)

server (Machine Type 8871) can run even more workloads, 24 x 7, and gain faster business insights. Integrated

with Intel Xeon processor E5-2600 v4 product family and industry-leading two-socket storage capacity, the

System x3650 M5 delivers exceptional performance. Flexible and scalable internal storage

configurations include up to 28x 2.5-inch or 14x 3.5-inch drives with a wide selection of drive sizes and types.

Suggested uses: Database, cloud computing and virtualization, enterprise applications, collaboration/email,

business analytics and big data, virtual desktops, and Microsoft RemoteFX applications.

The following figure shows the System x3650 M5.

Figure 1. Lenovo System x3650 M5

Did you know?

The System x3650 M5 incorporates energy-smart features for minimized costs and efficient performance. Dual

fan zones support operation in up to 40°C environments. The 80 PLUS Titanium power supply units (PSUs) can

deliver 96% efficiency at 50% load.

The System x3650 M5 has outstanding memory performance that is achieved by supporting two-RDIMMs-per-

channel configurations at speeds up to 12% faster than the Intel specification, while still maintaining world-

class reliability.

System x® servers achieved the highest reliability of any x86 servers; see ITIC 2015 - 2016 Global Server

Hardware, Server OS Reliability Report, July 2015:

http://www.lenovo.com/images/products/system-x/pdfs/white-papers/itic_2015_reliability_wp.pdf

The System x3650 M5 integrates leadership security and reliability. System x Trusted Platform Assurance, an

exclusive set of System x features and practices, establishes a solid security foundation for your workloads.

Enterprise-class data protection is provided with optional self-encrypting drives, and advanced diagnostic

tools facilitate reduced downtime and costs.

Lenovo System x3650 M5 (E5-2600 v4)

1

Summary of Contents for 8871

Page 1: ...rgy smart features for minimized costs and efficient performance Dual fan zones support operation in up to 40 C environments The 80 PLUS Titanium power supply units PSUs can deliver 96 efficiency at 50 load The System x3650 M5 has outstanding memory performance that is achieved by supporting two RDIMMs per channel configurations at speeds up to 12 faster than the Intel specification while still ma...

Page 2: ... Virtualization Technology integrates hardware level virtualization hooks that allow operating system vendors to better utilize the hardware for virtualization workloads Up to 2400 MHz memory speeds with two DIMMs per channel running at 2400 MHz to help maximize system performance Up to 1 5 TB of memory capacity with 64 GB load reduced DIMMs or LRDIMMs The 12 Gbps SAS internal storage connectivity...

Page 3: ...roductivity through advanced server management capabilities An integrated Trusted Platform Module TPM enables advanced cryptographic functionality such as digital signatures and remote attestation System x Trusted Platform Assurance an exclusive set of System x security features and practices establishes a solid security foundation for workloads by delivering firmware that is securely built tested...

Page 4: ...he front of the System x3650 M5 server with up to 16x 2 5 inch drive bays and the Front IO Cage Standard optional Figure 3 Front view of the System x3650 M5 16x 2 5 inch drive bays Front IO Cage Standard optional The following figure shows the front of the System x3650 M5 server with up to 16x 2 5 inch drive bays and the Front IO Cage Advanced optional Figure 4 Front view of the System x3650 M5 16...

Page 5: ... bays The following figure shows the front of the System x3650 M5 server with 8x 3 5 inch drive bays Figure 6 Front view of the System x3650 M5 8x 3 5 inch drive bays The following figure shows the front of the System x3650 M5 server with 12x 3 5 inch drive bays Figure 7 Front view of the System x3650 M5 12x 3 5 inch drive bays Lenovo System x3650 M5 E5 2600 v4 5 ...

Page 6: ...he System x3650 M5 server Figure 8 Rear view of the System x3650 M5 The following figure shows the locations of key components inside the System x3650 M5 server Figure 9 Internal view of the System x3650 M5 Lenovo System x3650 M5 E5 2600 v4 6 ...

Page 7: ...0 LFF or LFF SFF SAS SATA hot swap drive bays 8x 3 5 front 2x 3 5 rear 8x 3 5 front 2x 2 5 rear Up to 8 SFF NVMe PCIe SSD non hot swap SFF SAS SATA hot swap drive bays 8x 2 5 SAS SATA front 4x 2 5 NVMe PCIe front 4x 2 5 NVMe PCIe front 8x 2 5 SAS SATA front 8x 2 5 SAS SATA front 4x 2 5 NVMe PCIe front Storage capacity Up to 119 6 TB with 8 TB 3 5 NL SAS or NL SATA HDDs and 3 84 TB 2 5 SAS SSDs Up ...

Page 8: ...alibrated Vectored Cooling with up to six redundant hot swap fans four standard additional two fans with the second processor two fan zones with N 1 fan redundancy each fan has one rotor Power supply Up to two redundant hot swap 550 W 750 W or 900 W 100 240V or 1500 W 200 240V High Efficiency Platinum AC power supplies or 750 W or 1300 W 200 240V High Efficiency Titanium AC power supplies or 900 W...

Page 9: ...60 v4 14C 2 0GHz 35MB 2400MHz 105W 1x 16GB M5210 2GB F 8x 2 5 HS 20 Open bay 4x GbE 3 9 Option Included 1x 750W HS 2 8871R2x 1x E5 2667 v4 8C 3 2GHz 25MB 2400MHz 135W 1x 16GB M5210 2GB F 8x 2 5 HS 20 Open bay 4x GbE 3 9 Option Included 1x 900W HS 2 8871J2x 1x E5 2680 v4 14C 2 4GHz 35MB 2400MHz 120W 1x 16GB M5210 2GB F 8x 2 5 HS 20 Open bay 4x GbE 3 9 Option Option 1x 900W HS 2 8871L2x 1x E5 2690 v...

Page 10: ...n Included 1x 900W HS 2 887116A 1x E5 2620 v4 8C 2 1GHz 20MB 2133MHz 85W 1x 16GB M5210 24x 2 5 HS 28 Open bay 4x GbE 3 9 None None 1x 900W HS 2 8871KGU 1x E5 2630 v4 10C 2 2GHz 25MB 2133MHz 85W 1x 16GB M5210 8x 2 5 HS 20 Open bay 4x GbE 3 9 Option Option 1x 900W HS 2 8871KHU 1x E5 2630 v4 10C 2 2GHz 25MB 2133MHz 85W 1x 16GB M5210 8x 3 5 HS 10 Open bay 4x GbE 3 9 Option Included 1x 900W HS 2 887116...

Page 11: ...20 2x 240GB SSD 4x GbE 3 9 Option Option 2x 900W HS 2 8871KSU 1x E5 2697 v4 18C 2 3GHz 45MB 2400MHz 145W 1x 16GB M5210 8x 2 5 HS 20 Open bay 4x GbE 3 9 Option Option 1x 900W HS 2 8871K6U 1x E5 2697 v4 18C 2 3GHz 45MB 2400MHz 145W 1x 32GB M5210 8x 2 5 HS 28 Open bay 4x GbE 3 9 None None 1x 900W HS 2 887116H 1x E5 2697 v4 18C 2 3GHz 45MB 2400MHz 145W 1x 32GB M5210 24x 2 5 HS 28 Open bay 4x GbE 3 9 N...

Page 12: ...3 9 Option Option 1x 900W HS 2 8871ESG 1x E5 2690 v4 14C 2 6GHz 35MB 2400MHz 135W 1x 16GB M5210 8x 2 5 HS 20 Open bay 4x GbE 3 9 Option Option 1x 750W HS 2 8871EUG 1x E5 2690 v4 14C 2 6GHz 35MB 2400MHz 135W 1x 16GB M5210 8x 2 5 HS 20 Open bay 4x GbE 3 9 Option Option 1x 900W HS 2 8871EVG 1x E5 2699 v4 22C 2 2GHz 55MB 2400MHz 145W 1x 16GB M5210 8x 2 5 HS 20 Open bay 4x GbE 3 9 Option Option 1x 1500...

Page 13: ... 2133 MHz 8 0 GT s 75 W Yes Yes Yes Yes E5 2630 v4 2 2 3 1 GHz 10 20 25 MB 2133 MHz 8 0 GT s 85 W Yes Yes Yes Yes E5 2630L v4 1 8 2 9 GHz 10 20 25 MB 2133 MHz 8 0 GT s 55 W Yes Yes Yes Yes E5 2637 v4 3 5 3 7 GHz 4 8 15 MB 2400 MHz 9 6 GT s 135 W Yes Yes Yes Yes E5 2640 v4 2 4 3 4 GHz 10 20 25 MB 2133 MHz 8 0 GT s 90 W Yes Yes Yes Yes E5 2643 v4 3 4 3 7 GHz 6 12 20 MB 2400 MHz 9 6 GT s 135 W Yes Ye...

Page 14: ...05W 00YJ214 ATF5 ATFW Intel Xeon Processor E5 2660 v4 14C 2 0GHz 35MB Cache 2400MHz 105W 00YJ205 ATEW ATFM Intel Xeon Processor E5 2667 v4 8C 3 2GHz 25MB Cache 2400MHz 135W 00YJ201 ATES ATFH Intel Xeon Processor E5 2680 v4 14C 2 4GHz 35MB Cache 2400MHz 120W 00YJ202 ATET ATFJ Intel Xeon Processor E5 2683 v4 16C 2 1GHz 40MB Cache 2400MHz 120W 00YJ216 ATF7 ATFY Intel Xeon Processor E5 2690 v4 14C 2 6...

Page 15: ...ver and it is a system wide setting System x engineering tested and validated system designs that support memory speeds beyond Intel memory specifications which provides benefits for workloads that require memory speed and density System x TruDDR4 memory is fully supported up to the rated speeds that are shown in the following table Table 6 System x3650 M5 maximum memory speeds and capacities DIMM...

Page 16: ...rage dense models with 8x 2 5 inch SAS SATA hot swap drive bays that can be upgraded to up to 28x up to 24 on the front up to 4 on the rear 2 5 inch SAS SATA hot swap drive bays 3 Models with 8x 3 5 inch SAS SATA hot swap drive bays that can be upgraded to the following drive bay configurations for a total of 10 drive bays a 8x 3 5 inch front 2x 3 5 inch rear SAS SATA hot swap drive bays b 8x 3 5 ...

Page 17: ...A5G6 1 System x3650 M5 16x 2 5 HS HDD Assembly Kit Single RAID None A5GF 1 System x3650 M5 16x 2 5 HS HDD Assembly Kit Dual RAID None A5GG 1 System x3650 M5 24x 2 5 HS HDD Assembly Kit Single RAID None A5G7 1 System x3650 M5 24x 2 5 HS HDD Assembly Kit Dual RAID None A5TN 1 System x3650 M5 24x 2 5 HS HDD Assembly Kit Triple RAID None A5G8 1 System x3650 M5 8x 3 5 HS HDD Assembly Kit None ATEG 1 Sy...

Page 18: ...8 8 x 2 5 inch HS drive models 1x x3650 M5 Plus 8x 2 5 HS HDD Assembly Kit with Expander PN 00FK661 Field upgrade for 16 16 x 2 5 inch HS drive models 1x x3650 M5 Plus 8x 2 5 HS HDD Assembly Kit PN 00FK676 3x RAID or HBA 8 8 8 drives Factory installed 1x x3650 M5 24x 2 5 HS HDD Assembly Kit Triple RAID FC A5G8 Field upgrade for 16 8 8 x 2 5 inch HS drive models 1x x3650 M5 Plus 8x 2 5 HS HDD Assem...

Page 19: ...rage dense models only models without the Standard feature code ATE5 or Advanced feature code ATE6 OP Panel 2x 2 5 inch rear drives 1x Rear 2x 2 5 HDD Kit are supported on 2 5 inch and 3 5 inch drive bay models The Rear 2 5 HDD Kit is installed in place of the PCIe Riser Card 1 and PCIe slots 1 2 and 3 are not present The kit includes special riser that provides PCIe 3 0 x8 slot for the M1215 RAID...

Page 20: ... and additional options used for internal storage of the System x3650 M5 server The internal storage controllers are supported in the PCIe slots in the following order Slot 0 dedicated slot Slot 4 Slot 1 and Slot 6 Slot 6 requires the second processor Table 11 RAID controllers and HBAs for internal storage Description Part number Feature code Maximum supported 12 Gb SAS SATA controllers ServeRAID ...

Page 21: ...HDD SSD SED HDD SSD SED HDD SSD Drive form factor SFF LFF SFF LFF SFF LFF Hot swap drives Yes Yes Yes Max devices 32 RAID 64 JBOD 240 1024 RAID levels 0 1 10 Optional 5 50 00AE930 0 1 10 Optional 5 50 RAID 5 FoD 47C8708 or cache upgrades Optional 6 60 47C8706 None JBOD mode Yes Yes without cache Yes Cache None 1 GB no backup 47C8656 1 GB flash backup 47C8660 2 GB flash backup 47C8664 4 GB flash ba...

Page 22: ... No Yes No N2215 Yes Yes Yes No No Yes No 4 8x 2 5 inch NVMe PCIe non hot swap front PCIe SSD Extender No No No No No No Yes Rear drive bays 2 4x 2 5 inch SAS SATA hot swap rear independent RAID M1215 Yes Yes Yes Yes Yes Yes No 2x 3 5 inch SAS SATA hot swap rear cascaded RAID M1215 Yes Yes Yes No No Yes No M5210 Yes Yes Yes No No Yes No N2215 Yes Yes Yes No No Yes No 2x 3 5 inch SAS SATA hot swap ...

Page 23: ...6 AT80 28 2 5 inch hot swap HDDs 6 Gbps NL SAS 500GB 7 2K 6Gbps NL SAS 2 5 G3HS HDD 00AJ121 A4TT 28 2 5 inch hot swap HDDs 6 Gbps NL SATA 500GB 7 2K 6Gbps NL SATA 2 5 G3HS HDD 00AJ136 A4TW 28 1TB 7 2K 6Gbps NL SATA 2 5 G3HS HDD 00AJ141 A4TX 28 2TB 7 2K 6Gbps NL SATA 2 5 G3HS 512e HDD 00NA526 AT81 28 2 5 inch hot swap SEDs 12 Gbps SAS 300GB 10K 12Gbps SAS 2 5 G3HS SED 00WG705 AT8D 28 600GB 10K 12Gb...

Page 24: ...s Enterprise Entry 6 Gbps SATA 120GB Enterprise Entry SATA G3HS 2 5 SSD 00YC385 AT8R 28 240GB Enterprise Entry SATA G3HS 2 5 SSD 00YC390 AT8S 28 480GB Enterprise Entry SATA G3HS 2 5 SSD 00YC395 AT8T 28 960GB Enterprise Entry SATA G3HS 2 5 SSD 00YC400 AT8U 28 Intel S3510 120GB Enterprise Entry SATA G3HS 2 5 SSD 00WG620 AT93 28 Intel S3510 240GB Enterprise Entry SATA G3HS 2 5 SSD 00WG625 AT94 28 Int...

Page 25: ...bps NL SAS 3 5 G2HS HDD 90Y8572 A2U0 14 3 5 inch hot swap HDDs 6 Gbps NL SATA 500GB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 81Y9786 A22Y 14 1TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 81Y9790 A22P 14 2TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 81Y9794 A22T 14 2TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 00FN113 A5VD 14 4TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 00FN143 A5VH 14 6TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 00FN173 A...

Page 26: ... None 1 The ODD Cable Kit part number 00AL956 includes two cables ODD Cable for 3 5 Model feature code A5GM and ODD Cable for 2 5 Model feature code A5V7 Ultraslim 9 5mm SATA DVD ROM part number 00AM066 supports the following media and speeds for reading CD ROM CD DA DAE 24X CD R RW 24X DVD ROM 8X DVD R 8X DVD R 8X DVD R DL 6X DVD R DL 8X DVD RW 8X DVD RW 8X DVD RAM 4 7 GB 5X Ultraslim 9 5mm SATA ...

Page 27: ...ht full length PCIe x16 slot is double wide Slot 2 PCIe 3 0 x8 full height full length not present if the slot 1 is PCIe x16 Slot 3 PCIe 3 0 x8 or ML2 full height half length Slot 4 PCIe 3 0 x8 low profile vertical slot on system planar Slot 5 PCIe 3 0 x8 low profile vertical slot on system planar Slot 6 PCIe 3 0 x16 or PCIe 3 0 x8 full height full length PCIe x16 slot is double wide Slot 7 PCIe 3...

Page 28: ...1 and 3 System x3650 M5 PCIe Riser 1 1 x16 FH FL 1 x8 ML2 Slots 00KA504 A5FR 1 System x3650 M5 PCIe Riser 1 2 x8 FH FL 1 x8 ML2 Slots 00KA519 A5FQ 1 System x3650 M5 PCIe Riser 1 x16 FH FL 1 x8 FH HL Slots 00KA489 A5FN 1 System x3650 M5 PCIe Riser 2 x8 FH FL 1 x8 FH HL Slots 00KA498 A5FP 1 Riser 2 options PCIe x8 riser supplies slots 6 7 and 8 PCIe x16 riser supplies slots 6 and 8 System x3650 M5 P...

Page 29: ...ort Stateless offload and performance features TCP IP and User Datagram Protocol UDP checksum offload TCP segmentation offload TCO Large Send Offload LSO Receive Side Scaling RSS and Transmit Side Scaling TSS Message Signal Interrupt MSI and Message Signal Interrupt Extension MSI X support Support for jumbo frames up to 9600 bytes The following table lists additional supported network adapters Tab...

Page 30: ...P Flareon Ultra 47C9977 A522 3 6 1 Gb Ethernet ML2 Intel I350 T4 ML2 Quad Port GbE Adapter 00D1998 A40R 1 1 Gb Ethernet PCIe Low Profile supported in low profile and full high PCIe slots Broadcom NetXtreme 2xGbE BaseT Adapter 42C1780 2995 4 8 Broadcom NetXtreme I Dual Port GbE Adapter 90Y9370 A2V4 4 8 Broadcom NetXtreme I Quad Port GbE Adapter 90Y9352 A2V3 4 8 Intel I350 F1 1xGbE Fiber Adapter 00A...

Page 31: ...SAS RAID adapters and HBAs for external storage Description Part number Feature code Maximum supported 12 Gbps SAS RAID adapters PCIe Low Profile ServeRAID M5225 2GB SAS SATA Controller supported in slots 1 2 6 00AE938 A5ND 2 3 Feature on Demand FoD upgrades for the M5225 one per server ServeRAID M5200 Series RAID 6 Upgrade 47C8706 A3Z5 1 ServeRAID M5200 Series Performance Accelerator 47C8710 A3Z7...

Page 32: ...rofile and Half High PCIe slots Emulex 16Gb FC Single port HBA Gen 6 16Gb FC not supported in slot 1 01CV830 ATZU 3 7 Emulex 16Gb FC Single port HBA not supported in slot 1 81Y1655 A2W5 3 7 Emulex 16Gb FC Dual port HBA Gen 6 16Gb FC not supported in slot 1 01CV840 ATZV 3 7 Emulex 16Gb FC Dual port HBA not supported in slot 1 81Y1662 A2W6 3 7 QLogic 16Gb FC Single port HBA Enhanced Gen 5 16Gb FC 01...

Page 33: ...998 ARYQ 2 5 2600GB Enterprise io3 Flash Adapter LP 00JY001 ARYR 2 5 Enterprise Value 1250GB Enterprise Value io3 Flash Adapter LP 00AE983 ARYK 2 5 1600GB Enterprise Value io3 Flash Adapter LP 00AE986 ARYL 2 5 3200GB Enterprise Value io3 Flash Adapter LP 00AE989 ARYM 2 5 6400GB Enterprise Value io3 Flash Adapter FH 00AE992 ARYN 3 6 The maximum quantity shown is with one processor two processors Th...

Page 34: ...ssor two processors Configuration notes The NVIDIA PCIe x16 adapters x16 wired are supported only in slots 1 and 6 and require PCIe x16 riser cards The NVIDIA PCIe x16 adapters x8 wired are supported in slots 1 2 6 and 7 with PCIe x8 or PCIe x16 riser cards or a combination of PCIe x8 and PCIe x16 riser cards with PCIe x16 riser cards slots 2 Riser 1 and 7 Riser 2 are not available All GPUs instal...

Page 35: ...ply 00FK930 A5ET 2 System x 750W High Efficiency Platinum AC Power Supply 00FK932 A5EU 2 System x 750W High Efficiency Titanium AC Power Supply 200 240V 00FK934 A5EV 2 System x 900W High Efficiency Platinum AC Power Supply 00FK936 A5EW 2 System x 900W High Efficiency 48 V DC Power Supply 00MU910 ASQF 2 System x 1300W High Efficiency Titanium AC Power Supply 200 240V 00MU911 ASQG 2 System x 1500W H...

Page 36: ... NBR 6147 2 8m line cord 39Y7929 6223 China 10A 250V C13 to GB 2099 1 2 8m line cord 39Y7928 6210 Denmark 10A 250V C13 to DK2 5a 2 8m line cord 39Y7918 6213 European 10A 230V C13 to CEE7 VII 2 8m line cord 39Y7917 6212 India 10A 250V C13 to IS 6538 2 8m line cord 39Y7927 6269 Israel 10A 250V C13 to SI 32 2 8m line cord 39Y7920 6218 Italy 10A 250V C13 to CEI 23 16 2 8m line cord 39Y7921 6217 Korea ...

Page 37: ...Key 4G SLC for VMware ESXi Downloads 00WH140 ATRM 1 Blank USB Memory Key for VMware ESXi Downloads 41Y8298 A2G0 1 32GB Enterprise Value USB Memory Key 00ML200 A5R7 1 SD Media Adapter and SD cards SD Media Adapter Option 00ML706 includes 2 blank 32GB SD cards 00ML706 A5TJ 1 Blank SD Media for System x 00ML700 AS2V 2 RAID Adapter for SD Media w VMware ESXi 5 1 U2 2 SD Media RAIDed None AS4B 1 RAID A...

Page 38: ...hts LEDs to help you diagnose the problem records the error in the event log and alerts you to the problem Optionally the IMM2 1 also provides a virtual presence capability for remote server management capabilities The IMM2 1 provides remote server management through industry standard interfaces Intelligent Platform Management Interface IPMI Version 2 0 Simple Network Management Protocol SNMP Vers...

Page 39: ...Standard feature code ATE6 System x3650 M5 2 5 Bezel with LCD Light Path feature code ATE8 and LCD display feature code A4VH If configured via CTO the LCD display feature code A4VH is derived when the Front IO Cage Standard feature code ATE6 and System x3650 M5 2 5 Bezel with LCD Light Path feature code ATE8 are selected Lenovo ToolsCenter Lenovo offers the following ToolsCenter software tools tha...

Page 40: ...rica Lenovo XClarity Administrator offers the following features Auto discovery and monitoring of Lenovo x86 servers RackSwitch switches and Flex System chassis Firmware updates and compliance enforcement Pattern based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting ...

Page 41: ...rs Using built in intelligence it identifies server power consumption trends and ideal power settings and performs cooling analysis so that you can define and optimize power saving policies Lenovo XClarity Energy Manager offers the following capabilities Reports vital server information such as power temperature and resource utilization Monitors inlet temperature to locate hot spots reducing the r...

Page 42: ... x Enterprise Slides Kit System x Gen II Universal Slides Kit System x M5 Custom Rail Kit Part number 00FK656 00KA500 00MW239 Rail type Full out slide ball bearing Full out slide ball bearing Half out slide friction Toolless installation Yes No Yes CMA support Yes Yes No In rack server maintenance Yes Yes No 1U PDU support Yes Yes Yes 0U PDU support Limited Limited Limited Rack type IBM and Lenovo...

Page 43: ...figuration result in system shutdown or design exposure at 40 C The worst case workload like Linpack Turbo On might have performance degradation Electrical Models with 1500 W Platinum power supplies 200 240 nominal V ac 50 Hz or 60 Hz 8 35 A Input kilovolt amperes kVA approximately Minimum configuration 0 15 kVA Maximum configuration 1 967 kVA Models with 1300 W Titanium power supplies 200 240 nom...

Page 44: ...vices website http lenovoquickpick com The following table explains warranty service definitions in more detail Table 35 Warranty service definitions Term Description Onsite Service If a problem with your product cannot be resolved via telephone a Service Technician will be dispatched to arrive at your location Parts Delivered If a problem with your product cannot be resolved via telephone and a C...

Page 45: ...anty upgrades and extensions Enterprise Software Support Lenovo Enterprise Server Software Support can help you troubleshoot your entire server software stack Choose support for server operating systems from Microsoft Red Hat SUSE and VMware Microsoft server applications or both operating systems and applications Support staff can help answer troubleshooting and diagnostic questions address produc...

Page 46: ...ts the external storage systems that are currently offered by Lenovo that can be used with the System x3650 M5 in storage solutions Table 37 External storage systems Description Part number Lenovo Storage N Series NAS storage Lenovo Storage N3310 70FX 70FY Lenovo Storage N4610 70G0 70G1 Lenovo Storage S Series SAS iSCSI or FC host connectivity Lenovo Storage S2200 LFF Chassis SAS Single Controller...

Page 47: ...orwize V3500 2 5 inch Dual Control Storage Controller Unit 6096CU3 IBM Storwize V3700 3 5 inch Storage Controller Unit 6099L2C IBM Storwize V3700 2 5 inch Storage Controller Unit 6099S2C IBM Storwize V3700 2 5 inch DC Storage Controller Unit 6099T2C IBM Storwize V5000 LFF Control Enclosure w 3 Yr S S 6194L2C IBM Storwize V5000 LFF Control Enclosure w 3 Yr S S LA 6194L2L IBM Storwize V5000 LFF Cont...

Page 48: ... 6171S7R External tape backup libraries IBM TS3100 Tape Library Model L2U 61732UL IBM TS3200 Tape Library Model L4U 61734UL Fibre Channel backup drives for TS3100 and TS3200 Tape Libraries 6173 LTO Ultrium 5 Fibre Channel Drive 00NA107 6173 LTO Ultrium 5 Half High Fibre Drive Sled 00NA113 6173 LTO Ultrium 6 Fibre Channel Drive 00NA115 6173 LTO Ultrium 6 Half High Fibre Drive Sled 00NA119 6173 LTO ...

Page 49: ... more information see the list of Product Guides in the Top of rack switches category http lenovopress com servers options switches Fibre Channel SAN switches The following table lists the Fibre Channel SAN switches that are offered by Lenovo that can be used with the System x3650 M5 in FC SAN storage connectivity solutions Table 40 Fibre Channel SAN switches Description Part number 8 Gb Fibre Cha...

Page 50: ... consoles that are offered by Lenovo that can be used in System x3650 M5 solutions Table 42 KVM switch and console options Description Part number Consoles 1U 18 5 Standard Console without keyboard 17238BX Console keyboards Lenovo UltraNav Keyboard USB US Eng 00MW310 Keyboard w Int Pointing Device USB Arabic 253 RoHS v2 46W6713 Keyboard w Int Pointing Device USB Belg UK 120 RoHS v2 46W6714 Keyboar...

Page 51: ...nt Pointing Device USB Turkish 179 RoHS v2 46W6738 Keyboard w Int Pointing Device USB UK Eng 166 RoHS v2 46W6739 Keyboard w Int Pointing Device USB US Euro 103P RoHS v2 46W6740 Keyboard w Int Pointing Device USB Slovenian 234 RoHS v2 46W6741 Console switches Global 4x2x32 Console Manager GCM32 1754D2X Global 2x2x16 Console Manager GCM16 1754D1X Local 2x16 Console Manager LCM16 1754A2X Local 1x8 Co...

Page 52: ... M5 solutions Table 44 Power distribution units Description Part number 0U Basic PDUs 0U 36 C13 6 C19 24A 200 240V 1 Phase PDU with NEMA L6 30P line cord 00YJ776 0U 36 C13 6 C19 32A 200 240V 1 Phase PDU with IEC60309 332P6 line cord 00YJ777 0U 21 C13 12 C19 32A 200 240V 346 415V 3 Phase PDU with IEC60309 532P6 line cord 00YJ778 0U 21 C13 12 C19 48A 200 240V 3 Phase PDU with IEC60309 460P9 line cor...

Page 53: ...P Gnd line cord 39Y8934 DPI 60amp 250V Front end PDU with IEC 309 2P Gnd line cord 39Y8940 DPI 63amp 250V Front end PDU with IEC 309 2P Gnd line cord 39Y8935 Universal PDUs 7x IEC 320 C13 outlets DPI Universal 7 C13 PDU with 2 m IEC 320 C19 to C20 rack power cord 00YE443 NEMA PDUs 6x NEMA 5 15R outlets DPI 100 127V PDU with fixed NEMA L5 15P line cord 39Y8905 Line cords for PDUs that ship without ...

Page 54: ...verything into a single invoice Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly As a premier client you have a dedicated finance specialist who manages your account through its life from first invoice through asset return or purchase This specialist develops an in depth understanding of your invoice and pa...

Page 55: ...ent are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parti...

Page 56: ...amic System Analysis Flex System Intelligent Cluster RackSwitch ServeRAID ServerGuide ToolsCenter TruDDR4 UpdateXpress System Packs The following terms are trademarks of other companies Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds in the United States other count...