8. Align the screw holes in the drive adapter and the solid-state drive with the corresponding holes in the
drive bracket. Then, install the five screws to secure the drive adapter and the solid-state drive to
the bracket.
Figure 88. Installing the screws to secure the drive adapter and the solid-state drive to the bracket
9. Slide the bracket with the solid-state drive into the drive bay from the front until it snaps into position
and then completely close the handle.
ID
Mem
CPU
PSU
Figure 89. Installing the bracket with the solid-state drive
10. Check the hard-disk-drive status LEDs to ensure that the solid-state drive is operating correctly. You
might have to restart the server for the newly installed solid-state drive to be recognized. See “Hot-swap
Chapter 6
.
Installing, removing, or replacing hardware
135