FRU
Applicable
test
Hard
disk
drive
Diagnostics
-->
Fixed
Disks
Diskette
drive
1.
Diagnostics
-->
Diskette
Drives
2.
Interactive
Tests
-->
Diskette
CD-ROM
or
DVD
drive
1.
Diagnostics
-->
Other
Devices
-->
CD-ROM/DVD
2.
Interactive
Tests
-->
CD-ROM/DVD
Test
Memory
1.
If
two
DIMMs
are
installed,
remove
one
of
them
and
run
Diagnostics
-->
Memory
Test
-
Quick
.
2.
If
the
problem
does
not
recur,
return
the
DIMM
to
its
place,
remove
the
other
one,
and
run
the
test
again.
3.
If
the
test
does
not
detect
the
error,
run
Diagnostics
-->
Memory
Test
-
Full
.
Fan
1.
Turn
on
the
computer
and
check
the
air
turbulence
at
the
louver
near
the
power
switch.
2.
Run
Diagnostics
-->
ThinkPad
Devices
-->
Fan
.
Product
overview
58
MT
2369/2370/2371/2372/2382/2386
Summary of Contents for 23717GU
Page 6: ...2 MT 2369 2370 2371 2372 2382 2386 ...
Page 54: ...Checkout guide 50 MT 2369 2370 2371 2372 2382 2386 ...
Page 97: ...Remove LCD module 4 4 Removing and replacing a FRU ThinkPad X40 series 93 ...
Page 138: ...LCD FRUs 12 1 in XGA TFT 1 2 3 4 5 6 7 8 Parts list 134 MT 2369 2370 2371 2372 2382 2386 ...