Alignment
pins
Alignment
pins
Step 6. Make sure that the 2-node scalability card is flush with the edge of the blade server.
Step 7. Alternately tighten the screws on the 2-node scalability card by hand to ensure that the screw
threads start properly.
Important:
Always hand tighten each screw before you use the 3/16" hex driver.
Step 8. Alternately tighten each screw on the 2-node scalability card using the 3/16" hex driver. Alternate
the tightening of each screw until both screws are tightened.
Note:
If you are using a torque driver, the correct torque is 15 in-lb.
Installing an IBM MAX5
Use these instructions to install an IBM MAX5.
Note:
Before installing the IBM MAX5 expansion blade, make sure that you have updated the firmware on
the BladeCenter HX5 blade server to the latest level. If you attach and try to use the IBM MAX5 expansion
blade without updating the server firmware, you might get unexpected system behavior or the server might
not power on. For information about updating the firmware on the BladeCenter HX5 blade server, see
“Updating firmware and device drivers” on page 84.
There are two versions of the IBM MAX5 expansion blade, referred to as the IBM MAX5 version 1 and IBM
MAX5 version 2 in this document. IBM MAX5 version 2 has a "MAX5" identifying label on the bottom of the
front bezel. The functionality of the two IBM MAX5 expansion blades are equivalent except for the type of
DIMMs supported. The type of DIMMs supported will differ, depending on the version of IBM MAX5
expansion blade installed. For the list of DIMMs available for your IBM MAX5 expansion blade, see the
Problem Determination and Service Guide
or go to http://www.ibm.com/supportportal/ for an updated parts
listing.
.
63
Summary of Contents for 1909
Page 1: ...BladeCenter HX5 Blade Server Installation and User s Guide Machine Types 7873 7872 1910 1909 ...
Page 80: ...72 BladeCenter HX5 Blade ServerInstallation and User s Guide ...
Page 112: ...104 BladeCenter HX5 Blade ServerInstallation and User s Guide ...
Page 116: ...108 BladeCenter HX5 Blade ServerInstallation and User s Guide ...
Page 120: ...112 BladeCenter HX5 Blade ServerInstallation and User s Guide ...
Page 126: ...118 BladeCenter HX5 Blade ServerInstallation and User s Guide ...
Page 133: ...Taiwan Class A compliance statement Appendix B Notices 125 ...
Page 134: ...126 BladeCenter HX5 Blade ServerInstallation and User s Guide ...
Page 139: ......
Page 140: ...Part Number 00V9872 Printed in China 1P P N 00V9872 ...
Page 141: ... 1P00V9872 ...