Lennox X-FIRES 1000-LP Installation And Operation Instructions Manual Download Page 19

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

19

REPLACEMENT PARTS - X-FIRES™ 1000

5

4

15

Hardware

12

1

2

5

9b

6

9a

7

8

10

11

13

14

See ordering instructions on 

Page 24

WARNING

CLEARANCES FROM COMBUSTIBLE MATERIALS

F860041/A

The following clearances must be maintained at all times.
Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual 
provided with the heater.

Note : Zero clearance from bottom of heater frame 
required for hard combustible floors. Minimum 4” 
clearance required to rugs or any fabric floor 
coverings. REFER TO INSTRUCTION MANUAL

IMPORTANT : Fabrics, curtains and drapes are not 
permited above the heater at any distance and within 
20” of the heater sides. No combustible shelves of any 
size are permitted above the heater.

Clearance to 
combustible 
sidewalls 4” 
(both sides)

Clearance to combustible ceiling 
32” measured from top of appliance 
glass panel

Clearance in 
front of 
heater 20”

F860041/A

Deben mantenerse en todo momento los siguientes espacios 
libres. El no hacerlo puede causar un riesgo de incendio. 
Consulte el manual de instrucciones suministrado con este 
aparato para obtener información completa.

Nota: No se requiere espacio libre desde el borde inferior del 
marco del calentador en caso de pisos combustibles duros. 
Se requiere un espacio mínimo de 4” entre el calentador y 
cualquier alfombra, moqueta o revestimiento de suelo de 
tela. CONSULTE EL MANUAL DE INSTRUCCIONES.

IMPORTANTE: No se permite la colocación de telas, cortinas y 

similares por encima del calentador a cualquier distancia, ni a 

una distancia de 20” de los laterales del calentador. No se 

permiten estantes combustibles de cualquier tamaño por 

encima del calentador.

Espacio hasta
paredeslaterales
combustibles
4” (ambos lados)

El espacio de 32” hasta un techo 
combustible se mide desde el borde 
superior del panel de vidrio del aparato

Espacio libre
delante del
calentador 20”

ADVERTENCIA

ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES

F860487 - ISSUE A - PRW

POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL

COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED

CENTRE LINE

LINEA DE CENTRO

FIREBO

X OUTLINE

C

ONT

ORNO DE LA CAMARA DE C

OMBUSTION

APPLIANCE OUTLINE 

 

C

ONT

ORNO DE LA AP

ARA

TO

FocalPointFires Single   27/06/08   

F860487 

Lennox 1000 fitting template

WALL MOUNTED VENT FREE FITTING TEMPLATE

PLANTILLA PARA LA INSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS

IMPORTANTE

ESTE APARATO UNICAMENTE DEBE SER 

COLGADO EN UNA PARED.

NO EMPOTRE NINGUN ELEMENTO DE 

ESTE APARATO.

ESTA PLANTILLA SIRVE UNICAMENTE 
PARA MARCAR LOS PUNTOS DE FIJA-

CION.

RETIRE LA PLANTILLA ANTES DE COLO-

CAR LE APARATO.

IMPORTANT

THIS APPLIANCE IS TO BE WALL HUNG 

ONLY. 

DO NOT RECESS OR INSET ANY PART OF 

THE APPLIANCE.

THIS TEMPLATE IS FOR THE MARKING 

OF FIXING POINTS ONLY.

 DO NOT INSTALL THE APPLIANCE WITH 

THIS TEMPLATE IN PLACE.

PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4

FIXING POINTS

PERFORE LA PLANTILLA PARA MARCAR LA POSICION DE LOS 4 TALADROS EN LA PARED

PUNTOS DE SUJECION

16”  (406mm)

13

/

16

”  (225mm)

3

/

8

”  (160mm)

3

1

/

8

”  

(78

.6

mm)

CONCEALED

GAS INLET

ENTRADA DE

GAS OCULTA

Artwork Size: W1002 x H642

X-FIRES  1000

Replacement Parts

Item # Cat. No.

Description

1

H6055

Glass Door Assembly

2

H6060

Catalyst

3

H6061

Pilot Assembly, Natural Gas

4

H6999

Pilot Assembly, Propane Gas

5

H7315

Burner Assembly, Natural Gas

6

H7317

Burner Assembly, Propane Gas

7

H6062

Catalyst Gasket

8

H7325

Large Back Glass

9a

H7002

Ball Knob

9b

H7041

Knob Spindle

10

H7328

Top Grill

11

H7313

Back Wrapper / Mounting Plate

12

H7318

Fitting Template

13

H7226

X-FIRES 1000-L, Limestone Surround

14

H7227

X-FIRES 1000-G, Granite Surround

15

H7006

Hardware Kit 

u

Optional Parts

16

93L32

FFGC   Flex Gas Line Kit

4

3

Hardware kits consists of the following:

 

6 ea . No .8 x 5/16 Screw Pozi Pan Head

 

6 ea . M6 x 12 Screw Pozi Pan Head BZP

 

6 ea . M4 x 12 Screw Pozi Pan Head Black

 

1 ea . Rubber Grommet

 

4 ea . Wall Plug

 

4 ea . Wall Fixing Screws

 

2 ea . Ceramic bracket

 

2 ea . Clevis Pin

16

Summary of Contents for X-FIRES 1000-LP

Page 1: ...uc tions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualifiedinstaller serviceagencyorthegassupplier WARNING If the information in t...

Page 2: ...years of dependable and enjoyable service from your fireplace Safety and Your Fireplace 2 3 Important Safety Information 4 Appliance Installation Service and Maintenance Notices 5 Appliance Operation...

Page 3: ...importantes relatives la s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con e...

Page 4: ...vec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette...

Page 5: ...pliance is Not convertible for use with other gases These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degrade the perform...

Page 6: ...reshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derated for thatelevation Consultyourlocalgassupplier...

Page 7: ...ies Inc to ANSI Z21 11 2 standard Massachusetts Requirements These fireplaces are approved for installation in the US state of Mas sachusetts if the following additional requirements are met Unvented...

Page 8: ...___ volume of space ft3 50 ft3 Maximum BTU Hr the space can support Example 3072 ft3 50 ft3 61 44 or 61 440 BTU Hr the space can support 3 Add the BTU Hr of all the fuel burning appliances in the spac...

Page 9: ...above the appliance It should be established that any mirrors or picture frames etc to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and moist...

Page 10: ...tested for soundness before any protection is applied and or the pipe work and fittings are buried 1 Remove the Grill Note This design of grill not fitted to widescreen model 2 Remove retaining wing...

Page 11: ...g clearances must be maintained at all times Failure to do so may result in the risk of a fire For full information refer to the instruction manual provided with the heater Note Zero clearance from bo...

Page 12: ...wall and drill holes for the additional fixing points as required Insert either wall plugs or cavity screw fixings as required Re position the outer casing on the wall and using a bubble level to chec...

Page 13: ...the fireplace cavity when rigid pipe is used Ensure that a sediment trap is installed upstream of the heater Figure 6 within the structure s piping system to prevent moisture and contaminants from pa...

Page 14: ...nd that extra ventilation may be needed during this time Advise to user to never place any objects on top of the appliance or obstruction this area in any way A periodic visual check of the pilot flam...

Page 15: ...s are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white vinegar and water Gas fireplace stove glass cleaner PAINTED AREAS These can be cleaned using a dry cloth LI...

Page 16: ...express both gas concentrations in terms of per centage To convert from parts per million ppm to a percentage divide the ppm figure by 10 000 Examples 35ppm 0 0035 15ppm 0 0015 5ppm 0 0005 Now divide...

Page 17: ...pilot is located on the left side behind the burner Figure 11 The control knob is located on the lower right hand side of the outer case It is marked as shown in Figure 10 6 Depress control knob in a...

Page 18: ...m with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY...

Page 19: ...or 20 ADVERTENCIA ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES F860487 ISSUE A PRW POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL COLOQUE EL NIVEL SOBRE ESTE BORDE PARA...

Page 20: ...s heater may result in property damage or personal injury Figure 13 4 off burner installation positions Figure 12 Glass Door Removal Remove the four 4 screws indicated then lift door off Visual check...

Page 21: ...6 11 1 4 25 1 4 21 3 16 15 3 4 23 3 4 7 1 2 21 7 16 4 1 2 39 7 16 11 1 4 25 1 4 21 3 16 15 3 4 23 3 4 7 1 2 2 4 1 2 Surround Specifications Product Reference Information Cat No Model Ship Wt Ship Volu...

Page 22: ...to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distance from mounting surface to regulator gas entry point D3 D1 D2 REGULATOR GAS ENTRY POINT D1 D3 D2 Finished...

Page 23: ...23 NOTES...

Page 24: ...red through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the app...

Reviews: