background image

Table of Contents   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2  

Safety and Your Fireplace

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2

FREE Safety Guard Offer

 (Protects Against Burns) 

 .  .  .  .  .  .  .  .  .  .  .  .  .  2

Important Safety Information

  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  4

[EN FRANÇAIS]

 L’information de sûreté importante 

   .  .  .  .  .  .  .  .  .  .  .  .  3–4

[EN ESPAÑOL]

 

Información importante de seguridad

 .  .  .  .  .  .  .  .  .  .  .  .  3–4

WHAT'S INSIDE

P/N 506023-01   Rev. D   04/2012 

MODELS

This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not 

prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appli-

ance is not convertible for use with other gases.

This is an unvented gas-fired heater. It uses air 

(oxygen) from the room in which it is installed. 

Provisions for adequate combustion and ventila-

tion air must be provided.  Refer to

 Combustion 

and Ventilation Air

 section in this manual.

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLER:

 Leave this manual 

 with the appliance.

CONSUMER: 

Retain this manual 

for future reference.

INSTALLATEUR : 

Laissez cette 

notice avec l'appareil.

CONSOMMATEUR :

 Conservez cette

notice pour consultation ultérieure.

 

DON’T

THROW 

IT AWAY!

This manual contains

important operating

and safety

information.

Wait...

F

R

E

E

See Page 2 For Details

SAFETY

GUARD

PROTECTS AGAINST BURNS

- Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other 

appliance.

- WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 

•  Do not touch any electrical switch; do not use any 

phone in your building. 

• Immediately call your gas supplier from a neigh-

bor’s phone.  Follow the gas supplier’s instruc-

tions. 

•  If you cannot reach your gas supplier, call the fire 

department.

- Installation and service must be performed by a   

    qualified installer, service agency or the gas supplier.

WARNING:  If the information in these instructions is 

not followed exactly, a fire or explosion may result 

causing property damage, personal injury or death.

- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs 

ou liquides inflammables dans le voisinage de cet appareil 

ou de tout autre appareil.

- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucan interrupteur. Ne pas vous servir des 

téléphones se trouvant dans le bâtiment où vous trouvez. 

• Appelez immédiatement votre fournisseur de gaz depuis 

un voisin. Suivez les instructions du fournisseur. 

• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez 

le service des incindies.

- L’installation  et  l’entretien  doivent  être  assurés  par  un 

installateur  ou  un  service  d’entretien  qualifié  ou  par  le 

fournisseur de gaz.

AVERTISSEMENT:  Assurez-vous de bien suivre les instruc-

tions données dans cette notice pour réduire au minimum 

le  risque  d’incindie  ou  d’explosion  ou  pour  éviter  tout 

dommage matériel, toute blessure ou la mort.

•  UNE SURFACE VITRÉE CHAUDE PEUT 

  CAUSER DES BRÛLURES.
•  LAISSER REFROIDIR LA SURFACE 

  VITRÉE AVANT D'Y TOUCHER.
•  NE PERMETTEZ JAMAIS À UN ENFANT 

  DE TOUCHER LA SURFACE VITRÉE.

•  HOT GLASS WILL

  CAUSE BURNS.
•  DO NOT TOUCH GLASS

  UNTIL COOLED.
•  NEVER ALLOW CHILDREN 

  TO TOUCH GLASS.

•  EL VIDRIO CALIENTE

   CAUSARÁ QUEMADURAS. 
•  USTED DEBE NUNCA  

  TOCAR EL VIDRIO CALIENTE. 
•  LOS NIÑOS DEBEN NUNCA 

  TOCAR EL VIDRIO.

WARNING 

/

 AVERTISSEMENT 

/

 AVISO  

Catalytic Vent-Free Fireplaces
X-FIRES™ 1000 Models

X-FIRES 1000-NG and X-FIRES 1000-LP

OTL Report No.  317-F-10-5

US

Portland

Manufacturer: Focal Point Fires plc. United Kingdom

Summary of Contents for X-FIRES 1000-LP

Page 1: ...uc tions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualifiedinstaller serviceagencyorthegassupplier WARNING If the information in t...

Page 2: ...years of dependable and enjoyable service from your fireplace Safety and Your Fireplace 2 3 Important Safety Information 4 Appliance Installation Service and Maintenance Notices 5 Appliance Operation...

Page 3: ...importantes relatives la s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con e...

Page 4: ...vec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette...

Page 5: ...pliance is Not convertible for use with other gases These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degrade the perform...

Page 6: ...reshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derated for thatelevation Consultyourlocalgassupplier...

Page 7: ...ies Inc to ANSI Z21 11 2 standard Massachusetts Requirements These fireplaces are approved for installation in the US state of Mas sachusetts if the following additional requirements are met Unvented...

Page 8: ...___ volume of space ft3 50 ft3 Maximum BTU Hr the space can support Example 3072 ft3 50 ft3 61 44 or 61 440 BTU Hr the space can support 3 Add the BTU Hr of all the fuel burning appliances in the spac...

Page 9: ...above the appliance It should be established that any mirrors or picture frames etc to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and moist...

Page 10: ...tested for soundness before any protection is applied and or the pipe work and fittings are buried 1 Remove the Grill Note This design of grill not fitted to widescreen model 2 Remove retaining wing...

Page 11: ...g clearances must be maintained at all times Failure to do so may result in the risk of a fire For full information refer to the instruction manual provided with the heater Note Zero clearance from bo...

Page 12: ...wall and drill holes for the additional fixing points as required Insert either wall plugs or cavity screw fixings as required Re position the outer casing on the wall and using a bubble level to chec...

Page 13: ...the fireplace cavity when rigid pipe is used Ensure that a sediment trap is installed upstream of the heater Figure 6 within the structure s piping system to prevent moisture and contaminants from pa...

Page 14: ...nd that extra ventilation may be needed during this time Advise to user to never place any objects on top of the appliance or obstruction this area in any way A periodic visual check of the pilot flam...

Page 15: ...s are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white vinegar and water Gas fireplace stove glass cleaner PAINTED AREAS These can be cleaned using a dry cloth LI...

Page 16: ...express both gas concentrations in terms of per centage To convert from parts per million ppm to a percentage divide the ppm figure by 10 000 Examples 35ppm 0 0035 15ppm 0 0015 5ppm 0 0005 Now divide...

Page 17: ...pilot is located on the left side behind the burner Figure 11 The control knob is located on the lower right hand side of the outer case It is marked as shown in Figure 10 6 Depress control knob in a...

Page 18: ...m with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY...

Page 19: ...or 20 ADVERTENCIA ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES F860487 ISSUE A PRW POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL COLOQUE EL NIVEL SOBRE ESTE BORDE PARA...

Page 20: ...s heater may result in property damage or personal injury Figure 13 4 off burner installation positions Figure 12 Glass Door Removal Remove the four 4 screws indicated then lift door off Visual check...

Page 21: ...6 11 1 4 25 1 4 21 3 16 15 3 4 23 3 4 7 1 2 21 7 16 4 1 2 39 7 16 11 1 4 25 1 4 21 3 16 15 3 4 23 3 4 7 1 2 2 4 1 2 Surround Specifications Product Reference Information Cat No Model Ship Wt Ship Volu...

Page 22: ...to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distance from mounting surface to regulator gas entry point D3 D1 D2 REGULATOR GAS ENTRY POINT D1 D3 D2 Finished...

Page 23: ...23 NOTES...

Page 24: ...red through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the app...

Reviews: