background image

care and operation 

instructions

A French manual is available upon request. Order P/N 506010-01CF
Ce manuel d’installation est disponible en francais, simplement en 

faire la demande. Numéro de la pièce 506010-01CF

MODELS

instaLLer:  Leave this manual with the appliance.

consuMer:  retain this manual for future reference.

DIRECT

 

VENT

SLDVT-35/40 SERIES

otL report no. 116-F-50-5

US

Portland

direct-Vent Gas FirepLace Heaters

p/n 506010-01 

 

reV. n/c  08/2008

do not store or use gasoline or other flammable 

vapors or liquids in the  vicinity of  this or any 

other appliance.

WHat to do iF You sMeLL Gas:

•  do not light any appliance.

•  do not touch any electrical switch; do not 

  use any phone in your building.

•  immediately call your gas supplier from a  

 

neighbor’s phone. Follow your gas supplier's 

  instructions.

•  if your gas supplier cannot be reached, call

  the fire department.

installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier

.

WarninG: iF tHe inForMation in tHis ManuaL 

is not FoLLoWed eXactLY, a Fire or eXpLo-

sion MaY resuLt causinG propertY daMaGe, 

personaL inJurY or Loss oF LiFe.

     

WarninGs

 

Hot!  do  not  touch!    the  glass  and 

surfaces of this appliance will be hot 

during operation and will retain heat 

for a while after shutting off the appli-

ance.  severe burns may result. 

• 

 

carefully  supervise  children  in  the 

same room as appliance.

 

if small children are present in the home, it is 

recommended that this appliance be fitted with 

a screen door or screen panel kit. see

 Pages 

13 & 14

 for ordering information. 

pour  Votre  sÉcuritÉ:    ne  pas  entreposer  ni 

utiliser d'essence ni d'autre vapeurs ou liquides 

inflammables dans le voisinage de cet appareil ou 

de tout autre appareil.
pour Votre sÉcuritÉ:  Que faire si vous sentez 

une odeur de gaz:
•  ne pas tenter d'allumer d'appareil.

•  ne touchez à aucun interrupteur.  ne pas vous 

servir des téléphones se trouvant dans le bati-

ment où vous vous trouvez.

•  evacuez la piéce, le bâtiment ou la zone.

•  appelez  immédiatement  votre  fournisseur  de 

gaz depuis un voisin.  suivez les instructions 

du fournisseur.

•  si vous ne pouvez rejoindre le fournisseur de 

gaz, appelez le service dos incendies.

L'installation et service doit être exécuté par un 

qualifié installeur, agence de service ou le fournis-

seur de gaz.

aVertisseMent:  assureZ-Vous  de  Bien 

suiVre Les instructions donnÉ dans cette 

notice pour rÉduire au MiniMuM Le risQue 

d'incendie ou pour ÉViter tout doMMaGe 

MatÉrieL, toute BLessure ou La Mort.

sLdVt-35ne

sLdVt-40ne

Millivolt Models

Electronic Models

sLdVt-35nM

sLdVt-35pM

sLdVt-40nM

sLdVt-40pM

Summary of Contents for SLDVT-35

Page 1: ...of this appliance will be hot during operation and will retain heat forawhileaftershuttingofftheappli ance Severe burns may result Carefully supervise children in the same room as appliance If small c...

Page 2: ...ge 13 Lighting Instructions Millivolt Page 16 Lighting Instructions Electronic Page 18 Maintenance Schedule Page 20 Troubleshooting Guide Millivolt Page 21 Troubleshooting Guide Electronic Page 22 Rep...

Page 3: ...e side and then the other so the tabs clear both of the locating holes On millivolt systems the piezo igniter HI LO flame adjustment knob and pilot and main gas OFF ON control knob are located below t...

Page 4: ...ce lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve Ifyourelectronicapplianceisequippedwithan optionalremotewallswitchorremotecontr...

Page 5: ...d Sooting on Page 10 The Homeowner must contact a qualified service technician at once if any abnormal condition is observed Small Area Paint Touch up The finish of the appliance is a high qual ity po...

Page 6: ...see Figure 5 1 To access the glass door securing latches firstopenthelowercontrolcompartmentdoor Figure 5 by lifting and pulling the bottom panel forward 2 Pull the latches forward and down to release...

Page 7: ...herightfrontlog 3 asshown Posi tion it on the two right front log brackets 4 Placetheleftrearlog 4 asshown Position it on the left rear log bracket 5 Place the right rear log 5 as shown Posi tion it o...

Page 8: ...er for the entire log set H7244 Step 2 Step 3 Step 4 3 Left Rear Bracket Step 1 Align hole at the bottom of left front log 1 over the left front bracket and the right front log over the right front br...

Page 9: ...ottom of left front log 2 over the left front bracket and the right front log over the right front bracket Step 3 Align the hole at the bottom of log 5 over the Nub of log 3 as shown Step 4 5 Step 1 S...

Page 10: ...reminutestoensurethattheflamenormal izes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation Air Shutter...

Page 11: ...rfireplace Please contact your Lennox dealer for any questions or concerns For the number of your nearest Lennox dealer please call 1 800 9 LENNOX Replacement parts A complete parts list is found at t...

Page 12: ...BOX W GR BK 120 VAC BK R TRANSFORMER 3V INTERMITTENT ELECTRONIC WIRING DIAGRAM BROWN BROWN BLACK BATTERY BACK UP TO WALL SWITCH FRS OR THERMOSTAT BLACK SENSOR BLACK IGNITOR SPARK TO PILOT IGNITOR IGNI...

Page 13: ...the transmitter When a button on the transmitter is pressed a signal light illuminates briefly to verify that a signal has been sent The Model RCL is designed to operate with all mil livolt ignition...

Page 14: ...DESIGN KITS Cat No Model Description Model Series 35 Arch Pane Door Charcoal 35 Arch Pane Door Satin Pewter SLDVT 35 H6106 APDML35C H6107 APDML35SP 40 Arch Pane Door Charcoal SLDVT 40 40 Arch Pane Do...

Page 15: ...rick Liner Kit Top Rear SLDVT 35 H0914 MBLK 40 Brick Liner Kit Top Rear SLDVT 40 Brickaded Panel Liner Kit The brickaded liner kits include ceramic panels as shown here The panels have brick like feat...

Page 16: ...p Pilot should remain lit If it goes out repeat steps 5 through 8 If knob does not pop up when released stop and immediately call your service technician or gas supplier If pilot will not stay lit aft...

Page 17: ...celle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pen dant environ 90 secondes apr s l allumage de la veilleuse Rel chez le bouton et il s...

Page 18: ...mation above on this page 2 Turn remote wall switch to OFF or set wall thermostat to lowest setting If used remove the batteries from the battery holder 3 This appliance is equipped with an ignition d...

Page 19: ...ur mural la position d arr t OFF 3 Ouvrez la porte du compartiment de contr le du bas 4 Assurez vousquelasoupaped arr tdelacanalisationprincipale est ouverte 5 Tournez la manette de r glage du gaz la...

Page 20: ...rior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the ap...

Page 21: ...e switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or rem...

Page 22: ...wire connection Check location of sensor Check vent system for obstructions Check for proper log placement Check for proper air shutter openings A Low voltage or bad lead wires B Damaged igniter wire...

Page 23: ...ecorative Volcanic Stone 80L42 1 80L42 1 9 Orifice Holder H7257 1 H7257 1 10 Gas Line Flexible Connector 93L32 1 93L32 1 Gas Controls SIT Millivolt Item No Description Natural Gas Propane Gas Part No...

Page 24: ...time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LHP 1110 West Taft Avenue...