Safety Precautions

If you discover any of the following, shut down your
unit, and contact a Lennox dealer for an inspection by
a licensed professional service technician (or equiva-
lent).

D

If you repeatedly hear any new or unfamiliar sounds
while your unit is operating, there may be a problem. For
example, poorly performing burners can produce unfa-
miliar noises.

D

If you smell any unusual odors, your unit may be operat-
ing improperly. For example, units can give off unfamil-
iar odors if components are required to operate in ab-
normal conditions.

D

Look for visible signs of a malfunctioning unit. Examples
include unusual amounts of condensate on windows in-
side your house, visibly burnt components or unusual
dirt or rust accumulations on the vent pipe or in the unit.

D

If you experience headache, nausea, fatigue, or dizzi-
ness, the cause could be exposure to carbon monoxide
gas. This is often misdiagnosed as the flu because
symptoms are similar. If you suffer from flu−like symp-
toms that are exaggerated at home, but seem to sub-
side while you are away from the house, exposure to
carbon monoxide could be the cause.

Your vigilance may pay off in early detection of a problem
before either personal injury or property damage occurs.
Do not hesitate to contact a qualified service technician as
an investment in your well being.

Planned Service

You should expect a service technician to check the follow-
ing items during an annual inspection. Power to the unit
must be shut off for the service technician’s safety.

Fresh air grilles and louvers 

(on the unit and in the room

where the furnace is installed) − Must be open and unob-
structed to provide combustion air.

Burners 

− Must be inspected for rust, dirt, or signs of water.

Vent pipe

 − Must be inspected for signs of water, damaged

or sagging pipe, or disconnected joints.

Unit appearance

 − Must be inspected for rust, dirt, signs

of water, burnt or damaged wires, or components.

Inner blower access panel

 − Must be properly in place and

provide a seal between the return air and the room where
the furnace is installed.

Return air duct 

− Must be properly attached and provide

an air seal to the unit.

Operating performance

 − Unit must be observed during

operation to monitor proper performance of the unit and the
vent system.

Combustion gases

 − Flue products must be analyzed and

compared to the unit specifications.

Problems detected during the inspection may make it nec-
essary to temporarily shut down the furnace until the items
can be repaired or replaced.

Pay attention to your furnace.

 Situations can arise be-

tween annual furnace inspections that may result in unsafe
operation. For instance, items innocently stored next to the
furnace may obstruct the combustion air supply. This could
cause incomplete combustion and the production of car-
bon monoxide gas.

Repair Parts List

The following repair parts are available through Lennox dealers. When ordering parts, include the complete furnace model
number listed on the CSA International nameplate −− Example: SL280DF090V48B−01. 

All service must be done by a li-

censed professional installer (or equivalent), a service agency, or the gas supplier.

Cabinet Parts

Access panel
Blower access panel
Top Cap

Control Panel Parts

Transformer
SureLight

®

 integrated control

Door interlock switch
Circuit Breaker

Blower Parts

Blower wheel
Motor
Blower housing cut−off plate

Heating Parts

Flame Sensor
Heat exchanger assembly
Gas manifold
Combustion air inducer
Gas valve
Main burner cluster
Main burner orifices
Pressure switches
Ignitor
Primary limit control
Secondary limit
Flame rollout switches

Summary of Contents for SL280DFV

Page 1: ...ions D If you cannot reach your gas supplier call the fire department D Extinguish any open flames GAS FURNACE Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed by a qualified installer service agency or the gas supplier E 2010 Lennox Industries Inc Dallas Texas USA D Leave the building immed...

Page 2: ... or more of these devices is activated furnace operation will stop If your home is left unattended for an extended period of time equipment op eration must be checked periodically If this is not possible the water supply to the house should be shut off and the pipes should be drained This will prevent problems associ ated with a NO HEAT condition frozen pipes etc CAUTION Before attempting to perfo...

Page 3: ...e must be performed by a licensed professional installer or equivalent a service agency or the gas supplier Safety Instructions 1 Keep the furnace area clear and free of combustible material gasoline and other flammable vapors and liquids If it is installed in an insulated area the furnace must be kept free of insulating material Insulating ma terial may be combustible 2 DO NOT obstruct air flow t...

Page 4: ...ext to the floor because some gas is heavier than air and will settle on the floor The gas valve on the SL280DFV is equipped with a gas control switch Use only your hand to turn the gas control switch Never use tools If the switch will not move by hand do not try to repair it Call a licensed professional service technician or equivalent Force or attempted re pair may result in a fire or explosion ...

Page 5: ...eat exchanger and burners for corro sion deterioration or deposits of debris Remove any ob structions Inspect the furnace venting system to make sure it is in place physically sound and without holes corrosion or blockage The vent connector must be correctly posi tioned and sloped upward The vent connector must be physically sound without holes or excessive corrosion Inspect the furnace return air...

Page 6: ...nspected for rust dirt or signs of water Vent pipe Must be inspected for signs of water damaged or sagging pipe or disconnected joints Unit appearance Must be inspected for rust dirt signs of water burnt or damaged wires or components Inner blower access panel Must be properly in place and provide a seal between the return air and the room where the furnace is installed Return air duct Must be pro...

Reviews: