WARNING

Product contains fiberglass wool.

Disturbing the insulation in this product during
installation, maintenance, or repair will expose you
to fiberglass wool. Breathing this may cause lung
cancer. (Fiberglass wool is known to the State of Cal-
ifornia to cause cancer.)

Fiberglass wool may also cause respiratory, skin,
and eye irritation.

To reduce exposure to this substance or for further
information, consult material safety data sheets
available from address shown below, or contact your
supervisor.

Lennox Industries Inc.
P.O. Box 799900
Dallas, TX 75379−9900

WARNING

Do not set thermostat below 60°F (16°C) in heating
mode. Setting thermostat below 60°F (16°C) reduces
the number of heating cycles. Damage to the unit
may occur that is not covered by the warranty.

WARNING

If overheating occurs or if gas supply fails to shut off,
shut off the manual gas valve to the appliance before
shutting off electrical supply.

WARNING

Do not use this furnace if any part has been under-
water. A flood−damaged furnace is extremely dan-
gerous. Attempts to use the furnace can result in
fire or explosion. Immediately call a licensed pro-
fessional service technician (or equivalent)  to in-
spect the furnace and to replace all gas controls,
control system parts, and electrical parts that have
been wet or to replace the furnace, if deemed neces-
sary.

NOTICE

Any additions, changes, or conversions required in
order for the appliance to satisfactorily meet the ap-
plication needs must be made by a licensed profes-
sional installer (or equivalent) using factory−speci-
fied and approved parts.

WARNING

Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a licensed professional installer (or
equivalent), a service agency, or the gas supplier.

Safety Instructions

 1 − Keep the furnace area clear and free of combustible

material, gasoline, and other flammable vapors and
liquids. If it is installed in an insulated area, the furnace
must be kept free of insulating material. Insulating ma-
terial may be combustible.

 2 −

DO NOT

 obstruct air flow to unit. Unit must receive an

unobstructed flow of combustion and ventilating air.
DO NOT block or obstruct air openings on the furnace
or air openings to the area in which the furnace is
installed. Take care to maintain established clear-
ances surrounding the furnace.

 3 −

DO NOT

 store chlorine or fluorine products near unit

or introduce these products into the combustion air.
These products can cause furnace corrosion.

 4 −

DO NOT draw return air from a room where this fur-
nace, or any other gas appliance (ie., a water heat-
er), is installed.

 When return air is drawn from a room,

a negative pressure is created in the room. If a gas ap-
pliance is operating in a room with negative pressure,
the flue products can be pulled back down the vent
pipe and into the room. This reverse flow of the flue
gas may result in incomplete combustion and the
formation of carbon monoxide gas. This toxic gas
might then be distributed throughout the house by the
furnace duct system.

WARNING

The blower door must be securely in place when the
blower and burners are operating. Gas fumes, which
could contain carbon monoxide, can be drawn into
the living space resulting in personal injury or death.

Your furnace is a gas appliance.

 It is critical that the gas

supplied to the unit be completely burned to avoid the pro-
duction of carbon monoxide gas. Complete combustion of
the gas requires, but is not limited to, correct gas pressure
and gas flow rate, adequate combustion air and proper
venting.

WARNING

Carbon monoxide gas is invisible, odorless, and
toxic.

Summary of Contents for SL280DFV

Page 1: ...ions D If you cannot reach your gas supplier call the fire department D Extinguish any open flames GAS FURNACE Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed by a qualified installer service agency or the gas supplier E 2010 Lennox Industries Inc Dallas Texas USA D Leave the building immed...

Page 2: ... or more of these devices is activated furnace operation will stop If your home is left unattended for an extended period of time equipment op eration must be checked periodically If this is not possible the water supply to the house should be shut off and the pipes should be drained This will prevent problems associ ated with a NO HEAT condition frozen pipes etc CAUTION Before attempting to perfo...

Page 3: ...e must be performed by a licensed professional installer or equivalent a service agency or the gas supplier Safety Instructions 1 Keep the furnace area clear and free of combustible material gasoline and other flammable vapors and liquids If it is installed in an insulated area the furnace must be kept free of insulating material Insulating ma terial may be combustible 2 DO NOT obstruct air flow t...

Page 4: ...ext to the floor because some gas is heavier than air and will settle on the floor The gas valve on the SL280DFV is equipped with a gas control switch Use only your hand to turn the gas control switch Never use tools If the switch will not move by hand do not try to repair it Call a licensed professional service technician or equivalent Force or attempted re pair may result in a fire or explosion ...

Page 5: ...eat exchanger and burners for corro sion deterioration or deposits of debris Remove any ob structions Inspect the furnace venting system to make sure it is in place physically sound and without holes corrosion or blockage The vent connector must be correctly posi tioned and sloped upward The vent connector must be physically sound without holes or excessive corrosion Inspect the furnace return air...

Page 6: ...nspected for rust dirt or signs of water Vent pipe Must be inspected for signs of water damaged or sagging pipe or disconnected joints Unit appearance Must be inspected for rust dirt signs of water burnt or damaged wires or components Inner blower access panel Must be properly in place and provide a seal between the return air and the room where the furnace is installed Return air duct Must be pro...