background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

20

Lennox Hearth Products reserves the right to make changes at any time, without notice, in
design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.

Printed in U.S.A. © 2001 by LENNOX HEARTH PRODUCTS

P/N  850,006M  REV.  C  04/2004

1110 West Taft Avenue
Orange, CA  92865

Summary of Contents for Signature CollectionEST-48-H ESTATE SERIES

Page 1: ...its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories may void the warranty listi...

Page 2: ...damage as a result of handling or transporta tion These items should be inspected by your distributor or qualified factory representative to ensure safe condition When in doubt con sult your distribu...

Page 3: ...obile homes These fireplace systems are designed for in stallation in accordance with the National Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in ac...

Page 4: ...amper is controlled through the use of a control lever located within the firebox opening at the top center just behind the firebox lintel Figure 3 The control lever snaps into place at the ex treme r...

Page 5: ...e Zone 45 12 Door Opening 1 12 The safety strips should extend from front of the fireplace at least 2 and should extend to be at least flush with the sides In the event a wooden support is used to ele...

Page 6: ...to be attached to the rear wall then the framed depth must be measured from the drywall surface It is important that this dimension be exact If the appliance is to be elevated above floor level a sol...

Page 7: ...igure 14 A B Ceiling Framing C D Roof Framing Corner Installation K D A E F Back Wall of Chase Enclosure Including Finising Materials if any Rough Framing Face Unfinished Shown FOAK Combustion Air Kit...

Page 8: ...chimney use 30 firestop spacer Model F10FS30 2 Use one nail on opposite sides to hold firestop spacer in position Nail permanently using at least two 2 more 8d nails after chimney sections have been a...

Page 9: ...ding flue pipe and locking outer stabi lizer section into place over the outer chimney pipe Position for proper clearance through framedopeningandnailstrapssecurely under tension in shear into place o...

Page 10: ...ng tabs are firmly engaged 4 PullupslightlyonCTDtoensurelockingjoint has firmly engaged Using a FTF13 CT1 Chase Termination Refer to specific installation instructions in cluded with FTF13 CT1 chase t...

Page 11: ...is 15 6 higher with offsets The maximum height for the system is 80 To determine the number of chimney sections andchimneycomponentsrequired followthese steps 1 Determine the total vertical height of...

Page 12: ...hes Feet Inches 12 18 36 MM M 461 38 5 0 1 13 11722 11 72 465 38 9 2 0 13 11824 11 82 471 39 3 1 1 13 11976 11 98 479 39 11 0 0 14 12179 12 18 489 40 9 1 0 14 12433 12 43 495 41 3 0 1 14 12586 12 59 4...

Page 13: ...2178 45 87 1 0 0 3 1 1149 2223 46 89 1 0 0 1 2 1175 2261 48 91 1 0 2 0 2 1226 2324 49 94 1 0 1 5 0 1257 2400 51 97 1 0 1 1 2 1302 2483 54 103 1 0 0 2 2 1378 2616 55 104 1 0 0 0 3 1403 2654 56 106 1 0...

Page 14: ...E OUTSIDE AIR IS 50 FEET ABOVE THE HEARTH PROVING THE AIR INLET IS TERMI NATED A MINIMUM OF THREE 3 FEET BE LOW THE CHIMNEY CAP LEVEL Note Combustion air inlet ducts must not terminate in attic space...

Page 15: ...surface of the indentation The refrac torymaterialisverythininthisareaandiseasily removed Once a small hole has been made continue tapping until you have reached suffi cientdiameterforthegaslinetofit...

Page 16: ...ick must this material be Using the k formula Desired k value of desired Min Thickness Required material per inch x of listed Thickness k value of listed material material per inch TM inches kM x T1 8...

Page 17: ...0 2 Offset Return Package 30 63L24 FTF13 ES30 INSTALLATION COMPONENTS The following items are available for use in the installation of this appliance The sum of all R values is 70 10 068 5825 1 4505 T...

Page 18: ...9 FTF13 12 63L20 FTF13 18 Chimney Section 63L21 FTF13 36 63L40 F10F6 Flashing 63L41 F10F12 Round Termination 63L44 FTF13 CTD Firestop Spacer Flat 63L36 F10FS 2 INSTALLATION COMPONENTS Storm Collar 63L...

Page 19: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 19...

Page 20: ...ges at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S...

Reviews: