FOR YOUR SAFETY:  Do not store or use gasoline
or other flammable vapors or liquids in the vicinity
of this or any other appliance.

FOR YOUR SAFETY:  What to do if you smell gas:

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone.

Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the

fire department.

Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.

18" & 24" Dual-Listed Gas Log Sets
P/N  850,021M  REV. B  03/2007

MODELS

SERENE HEAT SERIES

CAREFULLY REVIEW THE INSTRUCTIONS SUPPLIED WITH
THE DECORATIVE TYPE UNVENTED ROOM HEATER FOR
THE MINIMUM FIREPLACE SIZE REQUIREMENT.

DO NOT INSTALL THE APPLIANCE IN THE FIREPLACE, UN-
LESS THE FIREPLACE MEETS THE MINIMUM DIMENSIONS
REQUIRED FOR THE INSTALLATIONS (SEE PAGE 2).

This is an unvented gas log appliance.  It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided.  Refer to Combustion
and Ventilation Air Section, Page 3.

Due to high temperatures, the appliance should be located out
of traffic and away from furniture or draperies (see page 4).

Do not place clothing or other materials on or near this
appliance.

IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING YOUR UNVENTED ROOM
HEATERS.

SHGL-18VN-R

SHGL-24VN-R

SHGL-18VP-R

SHGL-24VP-R

SHGL-18MN-R

SHGL-24MN-R

SHGL-18MP-R

SHGL-24MP-R

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

OTL REPORT NO. 116-L-11-5

INSTALLATION INSTRUCTIONS
AND HOMEOWNER'S MANUAL

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.

WARNING: IMPROPER INSTALLATION, ADJUSTMENT, AL-
TERATION, SERVICE OR MAINTENANCE CAN CAUSE IN-
JURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL.
FOR ASSISTANCE OR ADDITIONAL INFORMATION CON-
SULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE
GAS SUPPLIER.

WARNING: DO NOT BUILD A WOOD FIRE. DO NOT BURN
WOOD OR OTHER MATERIAL IN THESE APPLIANCES.

Summary of Contents for SERENE HEAT Series

Page 1: ...nce It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventila tion air must be provided Refer to Combustion and Ventilation Air Section Page 3 Due to hig...

Page 2: ...Theseappliancesareequippedwithaspecially designed pilot utilizing an oxygen depletion sensor ODS which responds to the amount of oxygen available in the room and shuts the heater off before the oxyge...

Page 3: ...ve a confined or unconfined space 1 Determine the volume of space ft 3 Length x Width x Height _____ ft 3 Include adjoining rooms with doorless pas sagewaysorventilationgrillsbetweenrooms Example 24 L...

Page 4: ...on requirements Refer to Fig ures 1 through 7 for clearances Note Thefollowingstepsrepresentthenormal sequence of installation Each installation is unique however and might require a different sequenc...

Page 5: ...n in Figure 4 Table 3 Step 4 Wood mantel shelf or combustible projection requirements To install a wood mantel shelf or other combustible projection directly above the fireplace firebox refer to Table...

Page 6: ...n corrosion over time Never use an open flame to check for leaks A Light the appliance refer to the lighting instructions label in the control compartment or in the Homeowner s Care and Operation Inst...

Page 7: ...20341 for propane L P G heaters Replace the test point plug after pressure measurement ensuring no gas leaks Figure 9 The heater has a unitized base a front log and a top twig It is important to follo...

Page 8: ...me Characteristics The Serene Heat Gas Log Set features a new concept in integrated burner and log design The flames from the burner travel horizontally through the log set and emerge at the knot hole...

Page 9: ...he log set effortlessly with one simple motion The Model RCL comes complete with detailed operating instructions Thermostat 89L36 FWTK Wall Switch Kit 85L87 FWSK Remote Control System Standard H0249 R...

Page 10: ...ural Piezo 1 6 3 5 w c Max 10 5 w c Millivolt 0 113 24 000 Min 5 0 w c SHGL 18VP R 36 000 Propane LPG Piezo 6 3 10 0 w c Max 13 w c Millivolt 0 069 24 000 Min 11 w c SHGL 24VN R 39 000 Natural Piezo 1...

Page 11: ...djustment SHGL 18MN R 36 000 Natural Piezo 3 5 w c Max 10 5 w c Manual 0 126 25 000 Min 5 0 w c SHGL 18MP R 36 000 Propane LPG Piezo 10 0 w c Max 13 w c Manual 0 071 27 000 Min 11 w c SHGL 24MN R 39 0...

Page 12: ...t the flame failure detector from shutting off the gas while the probe is warming up 10 Release the control knob while turning counterclockwise to the preferred setting If the knob does not pop out wh...

Page 13: ...OT TO SCALE 13 Figure 15 Figure 14 Gas Control Knob Location Pilot Location Turn Control Knob to OFF Position Manual Turn Control Knob to IGN Position Manual Figure 17 Figure 16 Pilot O F F I G N L O...

Page 14: ...rn remote wall switch OFF The pilot will remain lit for normal service 2 For complete shutdown turn remote wall switch to OFF 3 Access the lower control compartment 4 Depress gas control knob slightly...

Page 15: ...orifice Replace burner Replace gas regulator Problem will stop after a few hours of operation Superior recommends running the heater with the excess ventilation for the first few hours Turn control kn...

Page 16: ...H1683 4 Twig H1681 H1684 5 Burner H1196 H1196 6 Piezo Ignitor 10K86 10K86 7 Pilot Millivolt Natural 110344 110344 Pilot Millivolt Propane L P G 901915 901915 8 Orifice Burner NG 0 113 and 0 119 99K77...

Page 17: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 17 REPLACEMENT PARTS MILLIVOLT 7 1 13 8 5 2 10 6 11 12 3 9 4 Propane Pilot Shown...

Page 18: ...H1683 4 Twig H1681 H1684 5 Burner H1196 H1196 6 Piezo Ignitor 10K86 10K86 7 Pilot Manual Natural H1201 H1201 Pilot Manual Propane 120341 120341 8 Gas Regulator Natural 110353 110353 Gas Regulator Prop...

Page 19: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 19 REPLACEMENT PARTS MANUAL 7 2 5 1 9 8 12 11 6 10 3 4 Propane Pilot Shown...

Page 20: ...hanges at any time without notice in design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2...

Reviews: