background image

 

Wiring Diagram

 

 

 

 

Application  

 

RDF300... / RDF400... 

RDF340 

RDF300... / RDF400...

 

  

ON

1    2

 

  

          

2-pipe 

 

 

 

en

 

L

N

10 A

L

N

Q1 Q2 Q3

Y11

Y21

AC

 23

0

 V

X1

M

X2

I

II III

N1

B2

S1

M1

Y1

QAH11.1 +
ARG86.3

5(2)A
max.

5(2)A
max.

AC 230 V

 

G

G0

G

G0

Q1 Q2 Q3

Y10

Y20

AC

 2

4

V

X1

M

X2

I

II III

N1

M1

L

N

L

Y1

max. 

±

1 mA

 

B2

S1

QAH11.1 +
ARG86.3

G - G0  AC 24 V
L - N   AC 230 V

 

L

N

10 A

L

N

Q1 Q2 Q3

Y11

Y21

AC

 23

0

 V

X1

M

X2

I

II III

N1

B2

S1

M1

C1

QAH11.1 +
ARG86.3

5(2)A
max.

5(2)A
max.

AC 230 V

 

  

ON

1    2

 

  

          

2-pipe & el. heat

er 

 

 

 

 

en

 

L

N

10 A

L

N

Q1 Q2 Q3

Y11

Y21

A

C

 23

0 V

X1

M

X2

I

II III

N1

B2

S1

M1

Y1

QAH11.1 +
ARG86.3

E1

5(2)A
max.

5(2)A
max.

5(2)A
max.

AC 230 V

 

G

G0

G

G0

Q1 Q2 Q3

Y10

Y20

AC

 24

V

X1

M

X2

I

II III

N1

M1

L

N

L

Y1

max. 

±

1 mA

 

B2

S1

QAH11.1 +
ARG86.3

E1

max. 

±

1 mA

 

YR

G - G0  AC 24 V
L - N   AC 230 V

 

L

N

10 A

L

N

Q1 Q2 Q3

Y11

Y21

A

C

 23

0 V

X1

M

X2

I

II III

N1

B2

S1

M1

QAH11.1 +
ARG86.3

E1

5(2)A
max.

5(2)A
max.

5(2)A
max.

AC 230 V

C1

 

  

ON

1    2

 

  

           

4-pipe 

 

 

 

 

en

 

L

N

10 A

L

N

Q1 Q2 Q3

Y11

Y21

AC

 2

3

0

 V

X1

M

X2

I

II III

N1

M1 Y1

Y2

5(2)A
max.

5(2)A
max.

5(2)A
max.

B2

S2

B1

S1

 

G

G0

G

G0

Q1 Q2 Q3

Y10

Y20

AC

 2

4

V

X1

M

X2

I

II III

N1

M1

L

N

L

Y1

Y2

max. 

±

1 mA

 

max. 

±

1 mA 

S1

QAH11.1
/ QAA32

G - G0  AC 24 V
L - N   AC 230 V

 

L

N

10 A

L

N

Q1 Q2 Q3

Y11

Y21

A

C

 23

0 V

X1

M

X2

I

II III

N1

S1

M1

5(2)A
max.

5(2)A
max.

5(2)A
max.

AC 230 V

QAH11.1
/ QAA32

C1

C2

 

  

ON

1    2

 

  

          

2-pipe, 3 position output

 

 

 

 

en

 

L

N

10 A

L

N

Q1 Q2 Q3

Y11

Y21

A

C

 23

0 V

X1

M

X2

I

II III

N1

S1

M1

5(2)A
max.

5(2)A
max.

AC 230 V

QAH11.1 +
ARG86.3

Y1

 

 

T °C

T °C

T °C

P01

P02

P13

+

-

-

+

P14

-

+

P12

+

-

P01=0

+

-

P01=1

P01=2

P01=3

P01=4

T

T °C

X2

M

T

QAH11.1

T °C

X 2

M

X 2

M

 

Legend:             

   

 

Dimensions 

 

N1 RDF3xx / RD

M1 3 

Steps-Fan

 

Y1,Y2 Valve

 

C1,C2 Compressor 

E1 Electro 

heater 

S1 Operating 

mode 

switch-over 

contact (e.g. key card

 

YR Current 

valve 

B2 Heat/cool changeover sensor 

 

 

V ie w    

 

A

       

S e ctio n      B   -   B

A

B

B

60 mm

62

 m

m

49 mm

86 mm

62

 m

m

44 mm

5 mm

14 mm

86

 mm

10

 m

m

 

 

Summary of Contents for RDF300.02 ARG71

Page 1: ...lennoxemeia com RDF300 02 ARG71 Installation operating and maintenance RDF300 02 Remote control ARG71 Installation plastic box RDF300 02 IOM 0509 E ...

Page 2: ......

Page 3: ...Mounting Location of Thermostat Preparation and Deliverables Semi Flush Mounting RDF300 RDF340 RDF400 5 ...

Page 4: ...I III N1 B2 S1 M1 QAH11 1 ARG86 3 E1 5 2 A max 5 2 A max 5 2 A max AC 230 V C1 ON 1 2 4 pipe en L N 10 A L N Q1 Q2 Q3 Y11 Y21 AC 230 V X1 M X2 I II III N1 M1 Y1 Y2 5 2 A max 5 2 A max 5 2 A max B2 S2 B1 S1 G G0 G G0 Q1 Q2 Q3 Y10 Y20 AC 24V X1 M X2 I II III N1 M1 L N L Y1 Y2 max 1 mA max 1 mA S1 QAH11 1 QAA32 G G0 AC 24 V L N AC 230 V L N 10 A L N Q1 Q2 Q3 Y11 Y21 AC 230 V X1 M X2 I II III N1 S1 M1...

Page 5: ...stall 1 connexion 2 assembly and screwing 3 fitting together of regulation and displaying element without any risk of supplying cable handing Important Please check that controller fits to the case delivered Controller dimensions 53 mm L x 68 mm H x 46 mm P request adapted case with a 60 3 mm fixing distance 1 2 3 ...

Page 6: ...ut rating Heating cooling DC 0 10 V Electric reheater relay DC 0 10 V max 1 mA Max 5 2 A AC 230 V Input Multifunctional X1 X2 NTC cable sensor like QAH11 switch Setpoint setting range 5 40 C in 0 5 C increments Control algorithm 2P PI P Environmental conditions Temperature Relative humidity 0 50 C 95 Mounting type Semi flush mount fixing centers 60 3 mm Dimension visible part 86mm x 86mm x 14 mm M...

Page 7: ...F semi flush mounted room temperature controllers Main features Size 75 mm x 75 mm x 51 mm with fixing centers 60 3 mm For installation of all semi flush mount room temperature controllers Conformant to BSI standard BS4662 EN 50086 2 1 IEC 670 ...

Page 8: ...rates independently and always runs at the same speed Low medium or high Low fan speed Medium fan speed High fan speed By a single speed fan the mode can be changed between and Do you want to set your controller to standby Press the operating mode button several times until the display shows the symbol to indicate that standby is selected In standby only frost protection is active factory setting ...

Page 9: ...e filter on your HVAC equipment It will appear after fan operating hours and disappear when the controller is set to standby This reminder must be configured by your HVAC installer AL1 AL2 This alarm message tells you an external alarm has occurred AL1 AL2 The alarms are configured by your HVAC installer The controller can be used in systems either for heating only or cooling only manually selecti...

Page 10: ......

Page 11: ......

Page 12: ...BELGIUM AND LUXEMBOURG FRANCE GERMANY ITALY NETHERLANDS POLAND PORTUGAL SALES OFFICES OTHER COUNTRIES Due to Lennox s ongoing commitment to quality the specifications ratings and dimensions are subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause property damage or personal injury Installation and service must...

Reviews: