RECEIVER INDICATORS AND ON/OFF BUTTON SETTING IN THE INDOOR UNIT

5

Remote control signals are

got by this receiver.

RECEIVER window

It indicates that the unit is working

on cooling or heating mode

according the selection.

COMPRESSOR

indicator

Cool mode or automatic mode

operation has been selected.

COOL indicator

It indicates that heat

mode or automatic

mode operation has

been selected.

HEAT indicator

It indicates that the

unit is on operation. If

no more indicators are

on, the unit is

operating on fan

mode.

POWER indicator

DRY indicator

It indicates that the cool mode or

automatic mode operation has been

selected.

COOL indicator

It indicates that the unit is on operation.

If no more indicators are on, the unit

is operating in ventilation mode.

POWER indicator

It indicates that the heat mode is

selected, or automatic mode operation.

HEAT indicator

If the remote control is not available,

press this button to stop/start the unit.

Also, pressing the button repeated times,

the unit operating modes could be

selected according to the following

sequence: OFF-COOL-HEAT.

ON/OFF button

Remote control signals are got by this receiver.

RECEIVER window

It indicates that the dry mode has been

selected.

ALARM

The unit

will stop.

The  unit  is  working  on

cooling mode and the indoor

unit  coil  temperature  goes

below a set value.

The unit is working and the

temperature in the indoor unit

coil is too low: Check the

selected temperature . If the

alarm doesn't disappear

check the correct functioning.

Ceiling model: 

No indication.

Cassette:

 The compressor led

blinks while the rest of the leds

remain the way they were.

The unit

will stop

Ambient temperature regulation

probe error.

Check sensor connection.

Compressor overload.

During heating cycle the indoor

coil temperature has been too

high.

The unit

will stop

These protections are

automatic reset for the first

time. To reset for the second

time press button "ON/OFF"

until the alarm disappears.

If the alarm shows up again,

please check:

- Indoor coil temperature

probe connections.

- Indoor unit works properly

- Clean air filters.

Overflow of water condensing.

The float switch, has detected

 water Overflow.

The unit

will stop

These protections are

automatic reset, the alarm

resets automatically when

there is no more water.

If the alarm shows again:

Check the water drain, and

the float switch connections.

Ceiling model:

Sequence: The Power led is 4

seconds on and 3 seconds off .

Cassette: 

All leds are off.

Cool:
Power:

Cool:
Power:

Power:

VERSION 1 (CASSETTE MODEL)

VERSION 2 (CEILING MODEL)

DESCRIPTION

EFFECTS

ACTION

ANTI-FREEZE

PROTECTION

BROKEN SENSOR

DETECTION

HEAT OVERLOAD

OVERFLOW

INDICATION

Ceiling model:

Sequence: The Cool led blinks

while the Power led blinks once

every four seconds.

Cassette:

Sequence: The Cool led blinks

while the Power led is on.

Ceiling model:

Sequence: The cool led blinks 5

times, while the Power led is 3

seconds off and 2 seconds on.

Cassette:

Sequence: The Cool led blinks while

the Power led is on.

Summary of Contents for OLR-1X

Page 1: ...CONTROL OLR 1X English 02 2005 USER MANUAL...

Page 2: ...te control does not work or it only works near the unit the batteries must be replaced Never use used batteries Always use the same type of battery The batteries must be removed from the remote contro...

Page 3: ...nt from here INFRARED SIGNAL TRANSMISSION It indicates operation modes setting temperatures and time programming LCD DISPLAY Used to select the desired temperature Pressing the or buttons will increas...

Page 4: ...the fan operating mode can not be changed HIGH H MEDIUM M LOW L AUTOMATIC AUTO COOL DRY FAN Even though LOW speed has been selected on HEATING mode the unit protects itself changing automatically the...

Page 5: ...sing of the button will advance the time setting in 30 minutes interval 2 seconds after do not press ON button the signal is sent to the unit You can see the actual time and symbol remains on the disp...

Page 6: ...unit coil is too low Check the selected temperature If the alarm doesn t disappear check the correct functioning Ceiling model No indication Cassette The compressor led blinks while the rest of the l...

Page 7: ...art at low speed to prevent from air cool feeling until the indoor unit temperature reaches the set temperature then the unit will operate to the selected temperature DEFROST CYCLE When the unit is op...

Page 8: ...ND NETHERLANDS POLAND PORTUGAL RUSSIA SLOVAKIA SPAIN UKRAINE UNITED KINGDOM OTHER COUNTRIES LENNOXBENELUXN V S A www lennoxbelgium com LENNOXJANKAa s www janka cz LENNOXFRANCE www lennoxfrance com LEN...

Reviews: