Press ON/OFF button to start or stop the unit. When the unit is stopped, if you press this button, the unit will start and
the POWER indicator will be on.
When the unit is on, if you press this button, the unit will stop and the POWER indicator will be off.
1. HOW TO TURN ON/OFF THE UNIT
OPERATION
3
2. SELECTING THE UNIT'S OPERATING MODE
The operating mode is always indicated on the display.
Pressing the button
you can change the unit operating mode, and choose the one desired:
MODE
COOL: The unit is working on cooling mode to reach the
temperature desired. Receiver COOL indicator is on.
HEAT: The unit is working on heating mode to reach the
temperature desired. Receiver HEAT indicator is on.
AUTO: The system switches automatically from
cooling to heating mode, depending on the ambient
and desired temperature.
When the unit is working on cooling mode receiver
COOL indicator is on and HEAT indicator blinks. On
the other hand when the unit is working on heating
mode receiver HEAT indicator is on and COOL
indicator blinks.
DRY: The unit is working on dry operating mode.
3. SELECTING DESIRED ROOM TEMPERATURE (SET-POINT)
4. SELECTING THE FAN OPERATING MODE
FAN: The unit is working on fan operating mode.
NOTES:
- If FAN mode is selected, the AUTO fan operating mode can not be
selected.
- If DRY mode is selected, the fan operating mode can not be changed.
HIGH
H
MEDIUM
M
LOW
L
AUTOMATIC
AUTO
COOL
DRY
FAN
- Even though LOW speed has been selected on HEATING mode, the unit protects itself changing automatically the speed.
5. SLEEP FUNCTION
Set Point -0.5ºC
Hours
Set Point
Set Point -1ºC
Set Point -2ºC
ºC
Set Point+0.5ºC
Hours
Set Point
Set Point+1ºC
Set Point+2ºC
ºC
Pressing the buttons
or
allow to select the desired room temperature (set-point).
The button
allows the increase of the current set-point.
The button
allows the decrease of the current set-point.
The temperature range is from 16ºC / 60ºF to 30ºC / 85ºF.
To change from ºC to ºF or vice versa, press the buttons and at the same time.
NOTE: if we have selected FAN as the unit operating mode, the set-point can not be modified.
Pressing the button you can change the desired fan speed, according to the following sequence:
FAN
Press the button to activate this function; the symbol will be displayed on the remote control.
SLEEP
SWING
Press the button to activate this function; the symbol will be displayed on the remote control.
HEAT
HEAT
AUTO
DRY
FAN
COOL
AUTO
SLEEP FUNCTION ON
Increase the set point temperature as the
above drawing shows (FIG. 1).
SLEEP FUNCTION ON
Decrease the set point temperature as the
above drawing shows (FIG. 2).
0.5 1
2
HEATING MODE
0.5 1
2
COOLING MODE
FIG. 1
FIG. 2
The condensate pump starts automatically to work when the compressor is working on cooling mode or when the float switch
indicates overflow.
7. CONDENSATE PUMP
6. SWING FUNCTION