Maintenance

WARNING!

Turn off all power to unit at system disconnect switch (at the
outdoor unit) or circuit breaker

 

before performing any main­

tenance procedures! Failure to follow this warning could 
lead to personal injury or death.

Coil fins are very sharp! Take care not to touch the fins in
order to avoid injury.

Indoor Unit Filters

The indoor unit filter should be cleaned every three months, or
more frequently, if necessary.

Follow the steps below and in the illustrations to clean the filters.

1 -

Pivot indoor unit front panel out and up to access filters.

2 -

Gently pull each filter outward, then down to remove the fil­
ters from the unit

3 -

Use a vacuum cleaner to remove dust and dirt from each fil­
ter or wash the filters with warm water and a mild detergent.
Rinse filters thoroughly with clean water and set aside to air
dry.

CAUTION!

Do not use hot water to clean the filters. Exposure to wa­
ter temperatures above 113°F (45°C) will damage filter
media and frame.

4 -

Reinsert clean, dry filters and close unit front panel. Restore
power to unit.

1

2

3

4

Indoor Unit

Check to make sure that there are no objects on top of unit or around unit that may be obstructing air
flow. Check to make sure that indoor unit and wall bracket are secure and have not been damaged.
Use a clean, dry cloth to gently remove dust from the outer surface of the indoor unit. The cloth may
be slightly dampened with warm water, if necessary. Do not use soap or other cleaners.

CAUTION!

Hot water, soaps or other cleaning agents may damage indoor unit cabinet or display panel.
Do not use hot water (above 113°F [45°C]). Cloth must be damp only (NEVER WET) to avoid
damage to display. Do not use soap or other cleaning agents (window cleaner, abrasive
cleansers, etc.) to clean the indoor unit cabinet.

Outdoor Unit

Check to make sure that there are no objects on top of unit or around unit that may be obstructing air
flow. If the outdoor unit is installed on a wall bracket, make sure that bracket is secure and has not
been damaged. Use a clean, slightly dampened cloth to gently remove dust from the outer surface of
the outdoor unit. Do not use soap or other cleaners and DO NOT spray water into unit.

WARNING!

SHOCK HAZARD! DO NOT SPRAY water into outdoor unit. Failure to follow this warning could
lead to electrical shock, resulting in personal injury or death.

Lennox recommends annual inspection by a licensed professional service technician, or equiva­
lent.

Summary of Contents for MS8 SERIES

Page 1: ...is manual is the property of the homeowner and must be left with the user 2012 Lennox Industries Inc Dallas Texas USA MS8 Single Zone Mini Split System Air Conditioners and Heat Pumps 507022 01 10 201...

Page 2: ...essional service technician or equivalent must annually inspect this system This unit must be properly grounded Do not use this system if any part has been underwater A flood dam aged appliance is ext...

Page 3: ...Tape e p i p n o i t c e n n o C Air inlet Typical indoor unit shown Actual unit may be slightly different Front Panel Display Air outlet Filter Directional Louver Wireless remote control Temperature...

Page 4: ...ixed in a downward position In climates with very low winter temperatures it may be necessary to supplement heating by addi tional means space heater fireplace etc In heating mode the operating range...

Page 5: ...r unlock the remote control buttons When the remote control is locked the icon is displayed AUTO COOL DEHUMIDIFICATION FAN HEAT FAN button Press this button to select fan speed AUTO fan is the default...

Page 6: ...button and use and buttons to set time for sys tem shutdown When desired time is displayed press TIMER OFF button again Press SLEEP button to cancel sleep function In cooling mode SLEEP function incre...

Page 7: ...ver NOTE Actual louver position is different than what is shown on remote icon See comparison to the right Press the LOUVER SETTING button once to activate the full range oscillation mode from top to...

Page 8: ...uver Press once to activate full range oscillation Press more than once to scroll through and select one of five fixed positions or one of three other oscillating positions If function is activated wh...

Page 9: ...thin its receiving range to ensure proper system control Control should be kept at least 3 feet 914mm away from other electrical appliances televisions stereos etc to prevent signal interference If re...

Page 10: ...ts on top of unit or around unit that may be obstructing air flow Check to make sure that indoor unit and wall bracket are secure and have not been damaged Use a clean dry cloth to gently remove dust...

Page 11: ...nected or has circuit breaker tripped Is power shut down System is not cooling or heating efficiently Is temperature setting correct Are either the air inlet or air outlet blocked on the outdoor or in...

Page 12: ...stem an error code will replace the temperature setting displayed on the front cover of the indoor unit If more than one error has occurred the codes will alternate so that all codes are shown Make no...