background image

 

MP-36OD

P/N  775,540M  REV.  A  04/2006

Page 1 of 2

Appliance Specifi cations

Notes

Due to Lennox' ongoing commitment to quality, 
all specifi cations, ratings and dimensions are 
subject to change without notice.

All framing dimensions calculated for 1/2" dry wall 
at the fi replace face.  If sheathing the chase or 
fi nishing with other thickness materials, calcula-
tions will  need to be made.

See 

Installation Instuctions Manual 

for Ceiling 

and Roof Framing Dimensions.

Diagrams & Illustrations Not to Scale

Product Reference Information

Cat. 

No.

Model

Ship. 

Weight

Ship.

 Volume

H1933

MP-36OD

  175 lb.

17.3 cu. ft.

40"

(1016 mm)

Front

37"

(940 mm)

7-3/16” 

(183 mm)

 36"

(914 mm)

2"

(51 mm)

12-1/2" 

(318 mm)

37"

(940 mm)

20-1/4” 

(514 mm)

Left Side

Right Side

40"

(1016 mm)

27-1/4” 

(692 mm)

20-1/4” 

(514 mm)

7-13/16 

(198 mm)

Top View

Gas Line

Access

Combustion

Air Inlet

20-3/16” 

(513 mm)

9-7/8” 

(251 mm)

17-3/8” 

(441 mm)

32"

(813 mm)

9-5/8” 

(244 mm)

7-1/2” 

(191 mm)

27-7/8” 

(708 mm)

Appliance Top Spacer

Appliance

Top Spacer

Junction

Box

Gas Line

Access

42-1/2"

(1080 mm)

42-1/2"

(1080 mm)

1-1/4"

(32 mm)

9-1/16 

(230 mm)

12-7/8” 

(327 mm)

9-3/16” 

(233 mm)

Fireplace Framing

Header

(See 

Note **)

B

1

A

B

2

A

K

G

Inside Chase

Back Wall of Chase/Enclosure

Including Finishing Materials, if any.

Rough

Framing Face

(Unfinished Shown)

OAK-OD Combustion
Air Kit

A

Outside Chase

G

C

H

Including Finising Materials

if any

Rough

Framing Face

(Unfinished Shown)

Combustion

Air Kit - Optional

*

Outside Chase - Indoor Installations

Outside

Air Kit

G

A

Outside Chase

Back Wall of Chase/Enclosure
Including Finishing
Materials if any

Rough Framing Face
(Unfinished Shown)

Optional

Drainage

Line

**

Note:

 

When Framing With 6” Studs Header Must Be 17” 

(432mm) Higher.  Use Security Chimney’s OR15 Offset/Return 
Elbow To Recess The Chimney Back 2 1/2” (64mm).  Flat Frame 
Down To A False Header At (B

1

).  Maintain Required Clearance 

To Chimney At All Times.

* 1" Air Space to insulation & construction materials on back and sides.

OTL Report No. 116-F-35-2

Corner Installation

J

D

A

E

F

Back Wall of

Chase/Enclosure

Including Finising

Materials

if any

Rough
Framing Face
(Unfinished Shown)

OAK-OD Combustion

Air Kit 

Framing Dimensions

A

41-1/2"

1054 mm

B

1

37-1/2"

953 mm

B

2

54-1/2"

1384 mm

C

28-3/4"

730 mm

D

15-3/8"

391 mm

E

70"

1778 mm

F

35"

889 mm

G

20-5/8"

524 mm

H

19-5/8"

499 mm

J

49-1/2"

1257 mm

K

8"

203 mm

Reviews: