Page 24
TABLE 13
NOTE - Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and
Exhaust must be same pipe size.
NOTE - Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length calcu
-
lation.
Standard Termination at Elevation 0 - 2000 ft
N
o.Of
90°
Elbows
1-1/2” Pipe
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
Model
045 070 090 110 045
070
090 110 045
070
090
110 045 070 090 110
1
15
15
n/a n/a
61
46
24
n/a
100
80
43
n/a
127 127 108 108
2
10
10
56
41
19
95
75
38
122 122 103 103
3
n/a
n/a
51
36
14
90
70
33
117 117
98
98
4
46
31
n/a
85
65
28
112 112
93
93
5
41
26
80
60
23
107 107
88
88
6
36
21
75
55
18
102 102
83
83
7
31
16
70
50
13
97
97
78
78
8
26
11
65
45
n/a
92
92
73
73
9
21
n/a
60
40
87
87
68
68
10
16
55
35
82
82
63
63
Standard Termination Elevation 2001 - 10,000 ft
No. Of
90°
Elbows
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
045
070
090
110
045
070
090
110
045
070
090
110
1
35
25
15
n/a
100
73
43
n/a
127
127
108
108
2
30
20
10
95
68
38
122
122
103
103
3
25
15
n/a
90
63
33
117
117
98
98
4
20
10
85
58
28
112
112
93
93
5
15
n/a
80
53
23
107
107
88
88
6
10
75
48
18
102
102
83
83
7
n/a
70
43
13
97
97
78
78
8
65
38
n/a
92
92
73
73
9
60
33
87
87
68
68
10
55
28
82
82
63
63