background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

14

Electronic Appliance Checkout

To light the burner, refer to the lighting instruc-
tions on 

Pagex 19

.  Ensure the igniter lights the 

pilot. The pilot fl ame should engulf the fl ame 
sensor as shown in 

Figurex 18

.

With proper care and maintenance, your appliance 
will provide many years of enjoyment. If you should 
experience any problem, fi rst refer to the trouble 
shooting guide in this manual. If problem persists, 
contact your Lennox distributor.

WIRING DIAGRAMS

Wiring diagrams are provided here for refer-
ence purposes only.  This information is also 
provided on schematics attached directly to the 
appliance on a pullout panel located within the 
control compartment.  

WARRANTY

Your gas appliance is covered by a limited twenty 
year warranty. You will fi nd a copy of the war-
ranty accompanying this manual.  Please read 
the warranty to be familiar with its coverage.

Retain this manual. File it with your other docu-
ments for future reference.

REPLACEMENT PARTS

A complete parts list is found at the end of 
this manual. Use only parts supplied from the 
manufacturer. Normally, all parts should be 
ordered through your Lennox distributor or 
dealer. Parts will be shipped at prevailing prices 
at time of order.

When ordering repair parts, always give the 
following information:

1.

 The model number of the appliance.

2.

 The serial number of the appliance.

3.

 The part number.

4.

 The description of the part.

5.

 The quantity required.

6.

 The installation date of the appliance.

If you encounter any problems or have any ques-
tions concerning the installation or application 
of this system, please contact your distributor, 
or Lennox directly:

LENNOX HEARTH PRODUCTS

1110 West Taft Avenue 
Orange, CA  92865

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your fi replace.  Please 
contact your Lennox dealer for any questions or concerns.  For the number of your nearest Lennox 
dealer, please call 800-731-8101

Your Fireplace's Model Number ________________________________________

Your Fireplace's Serial Number ________________________________________

The Date On Which Your Fireplace Was Installed ___________________________

The Type of Gas Your Fireplace Uses ____________________________________

Your Dealer's Name   ________________________________________________  

1. If any of the original wire as supplied must be replaced,

1.  

it must be replaced with

 

Type AWM 105

°

C – 18 GA.

wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Junction Box

Transf.

120 V.

24 V

BL

Electronic Wiring Diagram (Honeywell)

R

WT

BL

G

W

120

 VAC.

BK

W

Gas Valve

B

R

IGNITER

PILOT

ASSEMBLY

BK

G

Outlet Box Green

Ground Screw

Hot side of Outlet

*ON/OFF Switch (Integral

with Gas Valve)

White Wire

To Opposite

Side

*Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

SPILL SWITCH

(high limit disc)

WT

G

Figure 18

3/8" to 1/2"

(9 -13 mm)

Ground

Electrode

Flame Rod

Hot Surface

Igniter

Proper Flame

Adjustment

Pilot
Nozzels

ELECTRONIC PILOT ASSEMBLY

Proper Pilot Flame Appearance

Figure 17

Proper Pilot Flame 
Appearance

Thermocouple

Thermopile

Pilot
Nozzels

MILLIVOLT PILOT ASSEMBLY

3/8" Min.

(9 mm)

Igniter Rod

Hood

Figure 20

If any of the original wire as supplied must 
be replaced, it must be replaced with Type 
AWM105 C - 18 gage wire.

* Optional Control Switches - OFF/ON wall 
switch  or  remote control receiver. 

Note: Turn the appliance-mounted OFF/ON 
burner control switch to the OFF position if an 
optional control switch is installed.

Millivolt Wiring Diagram

Figure 19

Thermopile

TH

TP

TH

TP

White

White

Black

Spill Switch

Schematic Represen-
tation Only

Field Wired

Factory 
Wired

* Optional Control Switch

Field Wired

Factory 
Wired

Schematic Represen-
tation Only

* Optional Control Switches - OFF/ON wall 
switch  or  remote control receiver. 

Millivolt Appliance Checkout

The pilot fl ame should be steady, not lifting 
or fl oating. Flame should be blue in color with 
traces of orange at the outer edge.

The top 3/8" (10 mm) at the pilot generator 
(thermopile) and the top 

¹⁄₈

" min (tip) of the 

quick drop out thermocouple should be engulfed 
in the pilot fl ame.  The fl ame should project 1" 
(25 mm) beyond the hood at all three ports. 
See 

Figure 17.

To light the burner, refer to the lighting instruc-
tions on 

Page 18.

 Appliance mounted OFF / ON Switch

CAUTION:  LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.  WIRING 
ERRORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION.

Summary of Contents for Merit Plus MPB35ST-NE

Page 1: ...ot store or use gasoline or other flammables or liquids in the vicinity of this or any other appliance FOR YOUR SAFETY What to do if you smell gas DO NOT light any appliance DO NOT touch any electrica...

Page 2: ...Electronic models have a fixed rate gas valve Input of electronic models is shown in the following table INTRODUCTION The millivolt appliances have a millivolt gas controlvalvewitha piezoignitionsyste...

Page 3: ...ngappliance voiding its warranty Any change to this appliance and or its operating controlsisdangerous Improper installation or use of this appli ance can cause serious injury or deathfromfire burns e...

Page 4: ...alve shown in Figure 3 Gas Control Compartment Access The gas controls can be found behind the control compartment access panel To open the control compartment access panel actuate the spring loaded m...

Page 5: ...ng pilot flame Exercise cau tion when using products with combustible vapors VENT OPERATION TEST A vent operation test is required as part of the installationtoverifythatproperventingcondi tions exist...

Page 6: ...d service technician should follow vent installation instructions for proper reassembly and proper sealing of the venting system components However more frequent periodic inspections and cleanings sho...

Page 7: ...s properly installed Generally the glass enclosure panels should not be removed except to gain access to the components within the firebox and the appliance may only be operated without the front glas...

Page 8: ...ulite Bag 2 liters F D Bottom View of Logs in packaging Top View of Logs C E A B Glowing Embers Bag of Glowing Embers rockwool Separate into Quarter Size separate Pieces Top View of Logs Installed E B...

Page 9: ...tted Distribute these pieces over the surface of the burner as shown in Figure 8 Do not use more than is necessary Ensure that the main burner ports remain uncovered by the ember material Note This ap...

Page 10: ...ar sooty Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be orange Air shutter gap should be increased If air shu...

Page 11: ...box Clean firebox walls and log grate Replace logs embers rockwool and vermiculite as detailed in this manual see Pagexs 8 10 Check Flame Patterns and Flame Height Homeowner Refer to Figurex 15 on Pag...

Page 12: ...ual Reset Spill Switch has Tripped or is defective Follow Manual Reset procedure on Page 6 Once the redresetbuttonisfullydepressedandclicksin check continuity with a multimeter between switch terminal...

Page 13: ...V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Chec...

Page 14: ..._____ The Date On Which Your Fireplace Was Installed___________________________ The Type of Gas Your Fireplace Uses ____________________________________ Your Dealer s Name ____________________________...

Page 15: ...on near the fireplace WhiteWallSwitchKit Cat No ModelNo Description 85L87 FWSK OFF ONWallSwitchKit ref Form 750 127M Touch Up Paint Kit Repair of minor scratches and discoloration of theappliancecharc...

Page 16: ...58 AD35C 35 Arch Doors Charcoal H0859 AD35TI 35 Arch Doors Textured Iron H0860 AD35SP 35 Arch Doors Satin Pewter H0861 AD35AB 35 Arch Doors Antique Brass Arch Pane Design Kits H0930 APD35C 35 Arch Pan...

Page 17: ...to previously installed Multi Open Series appliances The decorative arch kits can not be used in conjunction with the screen panel kit 35 Arch Door Kits Cat No Model No Description 26M43 ADK35CMPB Arc...

Page 18: ...AT TO DO IF YOU SMELL GAS Extinguish any open flame Open windows Do not light any appliance Do not touch any electrical switches TO TURN OFF GAS TO APPLIANCE 1 Turn remote wall switch OFF The pilot wi...

Page 19: ...s been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRU...

Page 20: ...l 11 H3358 1 Grate Assembly All 12 69L2101 4 Latch Glass Enclosure Panel All 13 H3354 1 Firebox Sub floor All Item Part Cat Qty Description Where Used Misc Replacement Parts 14 H3210 1 Log Set All 15...

Reviews: