background image

36

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Flex

LENNOX HEARTH PRODUCTS  •  MERIT

® 

 SERIES DIRECT-VENT GAS FIREPLACES  •  MODELS MLDVT-30/35/40/45  •  INSTALLATION INSTRUCTIONS

Cat. #

Model

Description

H1969

SF4.5HT-2

Horizontal Square Termina-

tion for flex

 (without flex)

77L87

SFKIT12S

Square Term. for flex 

(with 12 inch [305 mm]* 

compressed flex)

77L88

SFKIT18S

Square Term. for flex 

(with 18 inch [457 mm]* 

compressed flex)

77L89

SFKIT24S

Square Term. for flex 

(with 24 inch [610 mm]* 

compressed flex)

77L90

SFKIT36S

Square Term. for flex 

(with 36 inch [914 mm]* 

compressed flex)

77L91

SFKIT48S

Square Term. for flex 

(with 48 inch [1219 

mm]* compressed flex)

94L04

SFKIT12SS

Small Square Termination 

for flex,

 with 12 in. (305 

mm) of *compressed flex 

vent 

(ref. Instr. P/N 750204M)

94L05

SFKIT18SS

Small Square Termination 

for flex,

 with 18 in. (457 

mm) of *compressed flex 

vent 

(ref. Instr. P/N 750204M)

94L06

SFKIT24SS

Small Square Termination 

for flex,

 with 24 in. (610 

mm) of *compressed flex 

vent 

(ref. Instr. P/N 750204M)

94L07

SFKIT36SS

Small Square Termination 

for flex,

 with 36 in. (914 

mm) of *compressed flex 

vent 

(ref. Instr. P/N 750204M)

94L08

SFKIT48SS

Small Square Termination 

for flex,

 with 48 in. (1219 

mm) of *compressed flex 

vent 

(ref. Instr. P/N 750204M)

94L09

SF-HTSS

Horizontal  Small  Square 

Termination for flex, without 

flex vent 

(ref. Instr. P/N 750204M)

56L74

SFVT30

Vertical Termination for 

flex

 (flat to 6/12) with flex 

adaptor, section of rigid 

vent, roof support collar 

assembly, roof flashing 

and storm collar. 

(ref. Instruction P/N 750052M)

 56L75

SFVT45

Vertical Termination for 

flex

 (6/12 to 12/12) with 

flex adaptor, section of 

rigid vent, roof support 

collar assembly, roof 

flashing and storm collar. 

(ref. Instruction P/N 750052M)

91L66

SFGC4-6

Gear  Clamp  4.5  in.  (114 

mm) for 

flex

 (6-pack)

91L67

SFGC7-6

Gear Clamp 7.5 in. (190.5 

mm) for 

flex

 (6-pack)

H7748

FVK36

36" 

Flex Connector Kit

Note: Flex attaches to  

appliance collar at one end 

and to rigid venting at other 

end.

Listed Secure Vent™ Components

Cat. #

Model

Description

17M52

SV4.5HGS-1

Termination Guard, Square 

(1-pack) 

(ref. Instruction P/N 750109M)

17M53

SV4.5HGS-12

Termination  Guard,  Hori-

zontal Square (12-pack)  

(ref. Instruction P/N 750109M)

87L02

SV4.5HGS

Termination Guard for 

Horizontal Square Termi-

nation (Deluxe) (1-pack) 

(ref. Instruction P/N 750055M)

H5820

SV4.5HTSK

Termination Shroud 

(Guard) for Horizontal 

Square Termination 

(1-pack) 

(ref. Instruction P/N 750246M)

H5816

750,247M

SV4.5-

TWSK10

Through Wall Shield Kit

(used to shield the direct-

vent pipe from blown 

insulation)

(ref. Instruction P/N 750247M)

H3907

SV4.5ARSA

Attic Insulation Shield w/

adjustable height, 12"-22"

96K93

SV4.5SU

Support Strap

10K81

SFMP

Mill-Pac, Black, High 

 

Temperature Sealant

89L40

SFMP-12

Mill-Pac, Black, High 

 

Temperature Sealant - 

Bulk 12-pack

99L02

SV4.5HRK14 Horizontal Riser Kit, 14"

(ref. Instruction P/N 750146M)

99L03

SV4.5HRK36 Horizontal Riser Kit, 36"

(ref. Instruction P/N 750146M)

H1988

CTSA-33

Chase Top Shroud Kit, Arch 

Top  3 X 3 Ft.

(ref. Instruction P/N 750194M)

H1985

CTSO-33

Chase Top Shroud Kit, 

Open Top  3 x 3 ft.

(ref. Instruction P/N 750193M)

H1987

CTSO-44

Chase  Top  Shroud  Kit, 

Open Top  4 x 4 ft.

(ref. Instruction P/N 750193M)

H1986

CTSO-46

Chase  Top  Shroud  Kit, 

Open Top  4 x 6 ft.

(ref. Instruction P/N 750193M)

Listed Secure Flex™ Components

These termination kits include firestop/spacer, gear clamps and flex adaptor. 

60L10

SF-18

18 feet (5.49 m) * 

 

compressed flex

(ref. Instruction P/N 750053M)

98K03

SF-12

12 feet (3.66 m) * 

 

compressed flex

(ref. Instruction P/N 750052M)

H2248

SF4.5HF-10

Firestop/Spacer-Horizontal, 

flex

  (3-1-1 spacing)

10-Pack

H2249

SF4.5VF-10

Firestop/Spacer-Vertical,  

flex 

(1-1-1 spacing)

10-Pack

INSTALLATION ACCESSORIES CONTINUED

*

All compressed flex vents can be expanded up to two times.

Seala

nt

(Fits H1968)

(Fits 94L10 

& H1968)

(Fits 94L10 

& H1968)

Summary of Contents for Meris SeriesM LDVT-45NE

Page 1: ...T AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y...

Page 2: ...lation The Electronic appliances have an electronic intermittent pilot ignition system External electrical power is required to operate these units The battery back up can be used in case of a power o...

Page 3: ...lation de cet appareil These appliances comply with National Safety Standards and are tested and listed by ETL Intertek Report No 100326540PRT 001 to ANSI Z21 88 in Canada CSA 2 33 and CAN CGA 2 17 M9...

Page 4: ...jurisdiction and by the USA National Fuel Gas Code NFPA 54 ANSI Z223 1 latest edition or in Canada the CAN CSA B149 1 codes latest edition Installtheapplianceaccordingtotheregulations of the local au...

Page 5: ...le etc a metal or woodbarriercoveringtheentirebottomsurface must be used Cold Climate Insulation For cold climate installations seal all cracks around your appliance with noncombustible material and w...

Page 6: ...6 12 to 7 12 1 25 0 38 7 12 to 8 12 1 5 0 46 8 12 to 9 12 2 0 0 61 9 12 to 10 12 2 5 0 76 10 12 to 11 12 3 25 0 99 11 12 to 12 12 4 0 1 22 12 12 to 14 12 5 0 1 52 14 12 to 16 12 6 0 1 83 16 12 to 18 1...

Page 7: ...e t e m t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s...

Page 8: ...ment door Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements ShelfHeight Toprovideforthelowestpossibleshelfsurface the...

Page 9: ...eir equivalent Unit Being Secured by its Nailing Flanges to the Framing Left Side Front Corner of Fireplace Shown Right side requirements are the same NOTE The nailing flanges combustible mem bers and...

Page 10: ...Dimensions Model No A B C D MLDVT 30 in 30 1 4 35 1 4 39 1 4 16 mm 768 895 997 406 MLDVT 35 in 35 1 4 35 1 4 39 1 4 16 mm 895 895 997 406 MLDVT 40 in 40 1 4 40 1 4 44 1 4 16 mm 1022 1022 1124 406 MLD...

Page 11: ...nts outlined in the National Fuel Gas Code NFPA 54 latest edition USA or CAN CSA B149 1 latest edition Canada Also see Figure 13 Figure 15 Route Gas Line 3 76 mm Left Side Front Corner of Fireplace Fr...

Page 12: ...u foumisseunde gaz Useonlyapprovedventingcomponents See Approved Vent Components on Page 2 These fireplaces must be vented directly to the outside The vent system may not service multiple appliances a...

Page 13: ...4 1 1 3 5 5 2 4 4 0 2 2 0 1 1 5 1 5 8 3 5 5 7 8 4 4 1 0 0 2 1 1 4 1 9 4 5 5 7 5 4 1 0 2 1 1 1 5 1 8 5 5 5 6 4 0 0 0 0 2 1 2 1 5 2 6 5 5 7 8 6 4 1 0 0 0 2 1 3 1 5 8 6 5 5 7 3 7 4 0 1 0 0 2 1 3 1 3 7 5...

Page 14: ...nal specifications Where required a telescopic vent section SV4 5LA may be used to provide the installer withanoptionininstallingintightand confined spaces or where the vent run made up of fixed lengt...

Page 15: ...align with the required direction of the next vent run element Twist elbow sections in a clockwise direction onlysoastoavoidthepossibilityofunlocking any of the previously connected vent sections see...

Page 16: ...all the way down to at or near level SV4 5VF Secure Vent SF4 5VF Secure Flex firestop spacer must be used anytime vent pipe passes through a combustible floor or ceiling SV4 5HF Secure Vent SF4 5HF S...

Page 17: ...op Vent three elbows LENNOX HEARTH PRODUCTS MERIT SERIES DIRECT VENT GAS FIREPLACES MODELS MLDVT 30 35 40 45 INSTALLATION INSTRUCTIONS VERTICAL VENT FIGURES TABLES continued Horizontal Outside Wall Te...

Page 18: ...vent run element Twist elbow sections in a clockwise direction only so as to avoid the possibility of unlocking any ofthepreviouslyconnectedventsections see Figure 19 on Page 14 I Continue installatio...

Page 19: ...ng the use of the fireplace Young children should be carefully supervised when they are in the same area as a hot termination To prevent contact with hot surfaces we recommend the use of a Termination...

Page 20: ...NENT IN THE SYSTEM see Figure 31 Use Table 8 as an aid in venting component selection for a particular range of exterior wall thicknesses Figure 32 Top Vent ONE 90 DEGREE ELBOW ELBOW CONNECTION NOT DI...

Page 21: ...HEARTH PRODUCTS MERIT SERIES DIRECT VENT GAS FIREPLACES MODELS MLDVT 30 35 40 45 INSTALLATION INSTRUCTIONS See Table 8 on Page 20 as an aid in venting component selection for a particular range of ext...

Page 22: ...g Firestop Spacer SV4 5VF When using Secure FlexTM use Firestop Spacer SF4 5VF When using Secure Flex use Firestop Spacer SF4 5HF Wall Firestop Spacer SV4 5HF See Table 8 on Page 20 as anaidinventingc...

Page 23: ...proximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slidetheinnerflexpipeovertheadaptorcol lar Ensure the flexible vent pipe completely engages the adaptor collar to a d...

Page 24: ...TP TH TP IN ORANGE THTP BLACK TP GREEN TH TO WALL SWITCH OR THERMOSTAT Refer to Section A for millivolt appliances and Section B for electronic appliances The gas valve is set in place and pre wired a...

Page 25: ...itch to the OFF position 10 After the wiring is complete replace the cover plate Note No batteries to be installed in the battery holderuntilapoweroutage oriftheapplianceis to be operated solely with...

Page 26: ...ff valve and gas lex line and pull the assembly forward out of the compart ment Separate the shut off valve from the gas flex line Determine the length of pipe needed to route the gas line from the la...

Page 27: ...he pilot lighting instructions provided in the Care and Operation Instructions manual For piezo igniter location see Figure 41 on Page 26 millivolt appliances only Note Lighting Instructions are also...

Page 28: ...he rear log 1 as shown Position it on the left rear log bracket 2 Place the left front log 2 as shown Posi tion it against the left front of the log rack 3 Place the right front log 3 as shown Posi ti...

Page 29: ...35 H7666 Left Rear Log Bracket Right Rear Log Bracket Glowing Embers Do not place glowing ember over burner slots Log Rack Volcanic Stone 4 5 3 2 1 2 3 1 Position on the left rear log bracket Right Re...

Page 30: ...g bracket 4 2 3 Position the left front log 2 and the right front log 3 against the log rack 3 2 Log Number Description 1 Rear Log 2 Left Front Log 3 Right Front Log 4 Left Cross Log 5 Right Cross Log...

Page 31: ...hannel above the door Pull the door forward 4 Retrieve the glass door Visually inspect the gasket on the backside of the frame Gasket surface must be clean free of irregularities and seated firmly 5 I...

Page 32: ...HEARTH PRODUCTS MERIT SERIES DIRECT VENT GAS FIREPLACES MODELS MLDVT 30 35 40 45 INSTALLATION INSTRUCTIONS 1 Locateadjustmentrodandadjustairshutter to the standard setting as shown in Figure 50 adjust...

Page 33: ...ng flush with the finished wall position framework to accommodate the thickness of the finished wall Figure 53 See Page 5 for Cold Climate Insulation and Page 8 for Clearances Top of Appliance 3 76 mm...

Page 34: ...estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor o el termostato de pared quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola...

Page 35: ...V4 5VF 10 Firestop Spacer Vertical rigid 1 1 1 spacing 10 pack 96K92 SV4 5SP Support Plate LENNOX HEARTH PRODUCTS MERIT SERIES DIRECT VENT GAS FIREPLACES MODELS MLDVT 30 35 40 45 INSTALLATION INSTRUCT...

Page 36: ...in 190 5 mm for flex 6 pack H7748 FVK36 36 Flex Connector Kit Note Flex attaches to appliance collar at one end and to rigid venting at other end Listed Secure Vent Components Cat Model Description 1...

Page 37: ...e front glass door assembly See Figure 49 on Page 31 Step 3 Carefully remove the logs Take care not to break the logs Step 4 Refer to Figure 55 on Page 38 Remove the burner assembly with attached vent...

Page 38: ...sure regulator and diaphragm Discard allremovedcomponents Ensuretheprovided diaphragm is installed properly onto the replacement pressure regulator and install the new pressure regulator using the new...

Page 39: ...the orifice with the one provided with the kit Exercise extreme care to prevent damagetoorbreakageoftheigniterassembly All Models Step 9 Refer to Figure 55 on Page 38 and Figure 60 VERIFY THE PROPER O...

Page 40: ...time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1508 Elm Hill Pike Suite...