SAFETY PRECAUTIONS

SELECT THE BEST LOCATION

•  Please read this installation manual completely before 

installing the product.

•  If the power cord is damaged, replacement work shall be 

performed by authorized personnel only.

•  Installation work must be performed in accordance with 

the national wiring Standards by authorized personnel 
only.

•  Contact an authorized service technician for repair, 

maintenance or installation of this unit.

•  This appliance is not intended for use by persons 

(including children) with reduced physical, sensory or 
mental capabilities, or lack of experience and knowledge, 
unless they have been given supervision or instruction 
concerning use of the appliance by a person responsible 
for their safety.

•  Children should be supervised to ensure that they do not 

play with the appliance.

•  All the pictures in the instructions are for explanation 

purposes only. The actual shape should prevail.

•  The design and specifi cations are subject to change 

without prior notice for product improvement. Consult 
with the sales agency or manufacturer for details.

•  The seriousness is classifi ed by the following indications:

WARNING

This symbol indicates 
the possibility of death or 
serious injury

CAUTION

This symbol indicates 
the possibility of injury or 
damage to property

Indoor Unit

•  Avoid locating the unit near a heat source.

•  Remove any obstacles blocking the air circulation. 

•  Choose a location where air circulation in the room is 

good. 

•  Choose a place where drainage can be easily done.

•  Find a place where noise prevention or reduction is taken 

into consideration.

•  Do not install the unit near the doorway.

•  Ensure the free spaces indicated by arrows from the 

wall, ceiling, fence or other obstacles are observed.

•  Avoid any direct sunlight. If not possible, sunlight 

protection should be considered.

Outdoor Unit

•  If an awning is built over the unit to prevent direct 

sunlight or rain, be careful that heat radiation from the 
condenser is not obstructed.

•  Be aware that animals or plants may be affected by the 

discharge of hot air from the unit.

•  Keep free the spaces indicated by the diagram arrows 

from the wall, ceiling, fence or other obstacles.

•  Do not place any obstacles near the unit which may 

cause a short circuit of the discharged air.

Installation of outdoor unit

•  Anchor the outdoor unit with a bolt and nut 

10 or 

tightly and horizontally on concrete or a rigid mount. 

NOTE:

 The outdoor unit you have purchased should 

be like one of the following. Install the outdoor unit 
according to the dimensions as indicated below:

Outdoor unit dimensions

(W x H x D) mm

Mounting dimensions

A (mm)

B (mm)

670 x 540 x 250

481

276

760 x 590 x 285

530

290

775 x 545 x 310

600

320

700 x 540 x 240

458

250

845 x 700 x 320

560

335

780 x 540 x 250

549

276

685 x 430 x 260

460

276

 WARNING

1)  Install strictly in accordance with these instructions. 

If installation is not done properly, water leakage, an 
electric shock and a fi re may occur.

2)  Only use the supplied accessories and authorised parts 

for installation. Failure to do so may cause the unit to fail 
and cause water leakage, electrical shock or fi re.

3)  Install in a suitable location which can comfortably hold 

the unit’s weight. If not installed properly, the set will fall 
and cause damage or injury.

4)  For all electrical work, follow the requisite national 

wiring regulations and these installation instructions. An 
independent circuit and single outlet must be used. If 
electrical circuit capacity is insuffi cient or electrical work 
is defective, it may cause an electric shock or fi re.

5)  Use the specifi ed cable, connect tightly and clamp the 

cable so that the terminal is not impacted by any force. 
If the connection or fi xing is not adequate, it will cause 
overheating or a fi re at the connection point.

6)  Wiring routing must be properly arranged so that control 

board cover is fi xed securely. If control board cover is not 
fi xed perfectly, it will cause overheating at connection 
point of terminal and result in fi re or electric shock.

7)  When doing piping connections, take care not to let 

gases other than the specifi ed refrigerant go into 
the refrigeration cycle. Otherwise, it will cause lower 
capacity, abnormally high pressure in the refrigeration 
cycle and result in an explosion and personal injury.

8)  Do not modify the length of the power supply cord or use 

an extension cord. Do not share the single outlet with 
other electrical appliances. Doing so will cause fi re or 
electric shock.

 CAUTION

1)  This equipment must be earthed and installed with an 

earth leakage current breaker. It may cause an electric 
shock if grounding is not done correctly.

2)  Do not install the unit in a place where leakage of a 

fl ammable gas may occur. If gas leaks and accumulates 
near the unit, it may cause a fi re.

3)  Carry out drainage piping as specifi ed in these 

installation instructions. If drainage is not done correctly, 
water may enter the room and damage the furniture.