Page 6
Indoor Unit
Parts And Major
Functions
Indoor Unit Parts And Major Functions
2
Unit Parts
Air inlet
Display panel
Louver
Air outlet
Fig. 2.1
Operating Conditions
Use the system under the following temperatures for safe and effective operation. If the air
conditioner is used under different conditions, it may malfunction or become less efficient.
COOL mode
HEAT mode
DRY mode
Room Temperature
17°C - 32°C
(62°F - 90°F)
0°C - 30°C
(32°F - 86°F)
17°C - 32°C
(62°F - 90°F)
Outdoor
Temperature
0°C - 50°C
(32°F - 122°F)
-15°C - 24°C
(5°F - 76°F)
0°C - 50°C
(32°F - 122°F)
18°C - 54°C
(For special
tropical models)
0°C - 60°C
(For special
tropical models)
-15°C - 50°C
(5°F - 122°F)
(For models with
low temp. cooling
systems.)
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
When outside
temperature is below 0°C
(32°F ), we strongly
recommend keeping the
unit plugged in at all
time to ensure smooth
ongoing performance.
-7°C - 24°C
•
Inverter Split Type
COOL Mode
HEAT mode
DRY mode
Indoor
Temperature
17°-32°C (62°-90°F)
O°-30°C (32°-86°F)
17°-32°C (62°-90°F)
Outdoor
Temperature
18°-43°C (64°-109°F)
-7°-24°C (19°-75°F)
18°-43°C (64°-109°F)
-7°-43°C (19°-109°F)
(low temperature cooling models)
18°-54°C (64°-129°F)
(For special tropical models)
18°-54°C (64°-129°F)
(For special tropical models)
•
Fixed-speed Type