Lennox Healthy Climate WB2-12 Owner'S Manual Download Page 4

3

II. Operating Instructions

Your new Lennox Healthy Climate Humidifier is controlled by a manual

humidistat installed either in the living area or in the cold air return. It is important
to anticipate a drop in temperature and reduce the setting accordingly to avoid
excessive condensation. For example, with an outside temperature of 20° the
correct setting will be 35% relative humidity. If the temperature is expected to
fall to 0° that evening, then reduce the setting to 25% several hours prior to the
temperature change.

Observance of the recom-

mended relative humidity level
on your humidistat (see table)
is an important safeguard.
Condensation of water on inside
windows in the form of fogging
or frost is usually an indication
of excessive relative humidity.
The same condensation can
take place in other areas in

your home with the possibility of resulting damage.

Be sure to keep fireplace dampers closed when not in use. They provide an

excellent escape route for heat, as well as humidity. 

The humidistat can be used to determine the relative humidity in your home

during the winter. Turn the dial to the lower setting then reverse the dial direc-
tion slowly until a “click” is heard. At this point, read the relative humidity on the
dial. This will be very close to the actual relative humidity in your home.

To check the humidifier operation, set the humidistat above the click point,

make sure that the water saddle valve is open and that there is electricity to the
unit. The furnace blower motor must be operating for the humidifier to function.
After the humidifier has operated for several minutes and water is entering the
unit and coming out at the drain, reduce the humidistat setting below the click
point and the unit should automatically shut off. Now, set the humidistat dial at
the recommended inside relative humidity, depending on the outside tempera-
ture. Follow the suggested settings prior to a drop in the outside temperature. 

III. Effect of Water Characteristics

Your humidifier will operate effectively using either hard or mechanically

softened water. 

Any type of water (hard, soft, hot, or cold) is acceptable for use with the

WB2 or WP2 drain-type humidifiers. Hot supply water, 140° maximum, is rec-
ommended for all heat pump applications. The use of hot supply water will also
increase the unit’s capacity in other applications.

OUTDOOR-INDOOR RELATIVE HUMIDITY TABLE

Outside Temperature 

Recommended R.H.

+40°

45%

+30°

40%

+20°

35%

+10°

30%

25%

–10°

20%

–20°

15%

Summary of Contents for Healthy Climate WB2-12

Page 1: ...R E A D A N D S A V E T H E S E I N S T R U C T I O N S OWNER S MANUAL For Models WB2 12 WB2 17 WP2 18 Includes Safety Operating and Maintenance Instructions and Warranty ...

Page 2: ...age Turn humidistat to OFF before servicing Introduction Thank you for your recent Lennox Healthy Climate Humidifier purchase We sincerely appreciate your business and are pleased to add your name to our growing list of customers Now please take a few minutes and read this booklet This will familiarize you with the benefits you will receive from the equipment you just purchased and help you unders...

Page 3: ...e performance and minimum maintenance are assured by the design features of the Lennox Healthy Climate Humidifier All unit housing parts that come in contact with water are non metal and will never rust or corrode Neither heat nor water will affect them under normal operating conditions The evaporative media designed especially for uniform high evapora tion and the Scale Control Insert also effici...

Page 4: ... reverse the dial direc tion slowly until a click is heard At this point read the relative humidity on the dial This will be very close to the actual relative humidity in your home To check the humidifier operation set the humidistat above the click point make sure that the water saddle valve is open and that there is electricity to the unit The furnace blower motor must be operating for the humid...

Page 5: ...ected and cleaned periodically to assure continued proper unit performance Inspection and Service Instructions 1 Disconnect electrical power to the furnace and shut off water supply 2 Disconnect the water line at the inlet compression nut 3 Remove the in line strainer from inside the inlet side of the valve by using a small nail or wire 4 Flush the in line strainer clean or replace with a new stra...

Page 6: ... distribution tray and clean thoroughly This will only need to be done once 5 Slide the evaporative media 4 out from the white plastic Scale Control Insert 5 Clean the insert frame by twisting and flexing it to loosen the calcium deposits or use a putty knife Inspect the evaporative media Part No 52P66 for Model WB2 12 and Part No 59P94 for Model WB2 17 and substitute a new one if necessary Slide ...

Page 7: ...distribution tray and clean thoroughly This will only need to be done once 6 Slide the evaporative media 6 out from the white plastic Scale Control Insert 7 Clean the insert frame by twisting and flexing it to loosen the calcium deposits or use a putty knife Replace the evaporative media Part No 59P94 back into the Scale Control Insert with the red colored spot up and snap the black distribution t...

Page 8: ... CONTRACTOR AS CONTRASTED TO DEFECTS IN THE HUMIDIFIER ITSELF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID ONE YEAR PERIOD THE MANUFACTURER S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAM AGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BRANCH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WAR RANT...