background image

your new humidifier can do for you, and what you should do to receive maximum
benefits from it. This booklet is intended to answer these questions.

The humidifier operates in conjunction with the furnace blower motor. When

the humidistat calls for humidity and the blower motor is operating, water flows
to the distribution pan located at the top of the unit. The water is uniformly dis-
tributed across the width of the pan and through a scientifically designed system
of outlets. It flows by gravity over the evaporative media. Dry, hot air is moved
through the moisture-laden evaporative media where evaporation takes place.
The now-humidified air carries moisture in vapor form throughout the home.

The correct water flow is determined by an orifice in each unit. When

the unit is operating, there will be a small, steady stream of water to drain,
which flushes away most of the trouble-causing minerals.

Do not use the

saddle valve to regulate the water flow. It is designed to be completely opened
or closed. 

The minerals and solid residue not trapped by the replaceable evaporative

media are flushed down the drain. The drain also eliminates the problems
caused by stagnant water. This is the most effective and least expensive
method to dispose of trouble-causing minerals.

Trouble-free performance and minimum maintenance are assured by the

design features of the Lennox Healthy Climate Humidifier. All unit housing parts
that come in contact with water are non-metal and will never rust or corrode.
Neither heat nor water will affect them under normal operating conditions.

The evaporative media, designed especially for uniform, high evapora-

tion, and the Scale Control Insert also efficiently trap mineral deposits which
are often the cause of damage to working parts in ordinary humidifiers. No
“white dust” can be distributed throughout the living quarters. The evaporative
media must be in good condition to assure high capacity trouble-free perform-
ance. It should be changed annually.

The granular coating in the bottom of the distribution tray is designed to

provide equal distribution of water to each of the openings assuring an even
flow of water over the evaporative media. Do not clean the mineral scale off the
bottom of the water distribution tray at the end of the humidification season.
The scale provides an excellent track for the water to follow. This is actually
what we try to simulate with the synthetic coating in the bottom of the tray. If
the coating is removed, it is not necessary to purchase a new distribution tray.
You can accomplish the same uniform performance by applying a small
amount of liquid dish soap over the entire lower surface of the water distribu-
tion tray. This will allow the water to flow evenly through each of the openings.

2

Summary of Contents for Healthy Climate WB2-12

Page 1: ...R E A D A N D S A V E T H E S E I N S T R U C T I O N S OWNER S MANUAL For Models WB2 12 WB2 17 WP2 18 Includes Safety Operating and Maintenance Instructions and Warranty ...

Page 2: ...age Turn humidistat to OFF before servicing Introduction Thank you for your recent Lennox Healthy Climate Humidifier purchase We sincerely appreciate your business and are pleased to add your name to our growing list of customers Now please take a few minutes and read this booklet This will familiarize you with the benefits you will receive from the equipment you just purchased and help you unders...

Page 3: ...e performance and minimum maintenance are assured by the design features of the Lennox Healthy Climate Humidifier All unit housing parts that come in contact with water are non metal and will never rust or corrode Neither heat nor water will affect them under normal operating conditions The evaporative media designed especially for uniform high evapora tion and the Scale Control Insert also effici...

Page 4: ... reverse the dial direc tion slowly until a click is heard At this point read the relative humidity on the dial This will be very close to the actual relative humidity in your home To check the humidifier operation set the humidistat above the click point make sure that the water saddle valve is open and that there is electricity to the unit The furnace blower motor must be operating for the humid...

Page 5: ...ected and cleaned periodically to assure continued proper unit performance Inspection and Service Instructions 1 Disconnect electrical power to the furnace and shut off water supply 2 Disconnect the water line at the inlet compression nut 3 Remove the in line strainer from inside the inlet side of the valve by using a small nail or wire 4 Flush the in line strainer clean or replace with a new stra...

Page 6: ... distribution tray and clean thoroughly This will only need to be done once 5 Slide the evaporative media 4 out from the white plastic Scale Control Insert 5 Clean the insert frame by twisting and flexing it to loosen the calcium deposits or use a putty knife Inspect the evaporative media Part No 52P66 for Model WB2 12 and Part No 59P94 for Model WB2 17 and substitute a new one if necessary Slide ...

Page 7: ...distribution tray and clean thoroughly This will only need to be done once 6 Slide the evaporative media 6 out from the white plastic Scale Control Insert 7 Clean the insert frame by twisting and flexing it to loosen the calcium deposits or use a putty knife Replace the evaporative media Part No 59P94 back into the Scale Control Insert with the red colored spot up and snap the black distribution t...

Page 8: ... CONTRACTOR AS CONTRASTED TO DEFECTS IN THE HUMIDIFIER ITSELF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID ONE YEAR PERIOD THE MANUFACTURER S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAM AGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BRANCH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WAR RANT...