HCWP2 REQUIRED MAINTENANCE

Refer to figure 6 for parts identification when reviewing
the following procedure. Bold text indicates components
that are identified in the illustration.

Electric shock hazard. Can cause injury
or death. Disconnect all electrical power
supplies before servicing.  Shut off wa-
ter supply before disconnecting or tap-
ping into any water supply line.

WARNING

!

− Make sure the main power to furnace is

disconnected.

2 − Make sure the humidistat is in the 

OFF 

position.

3 − Disconnect electrical power to the humidifier and

make sure that the water supply is turned off.

− Pull the tab to release the control harness.

Disconnect the harness.

5 − Release the 

front cover latch

 at the bottom of the

humidifier assembly. Swing the cover open, then lift it
away from the assembly.

6 − Grasp the 

tabs 

on the 

pad assembly frame

 and lift

the assembly out of the humidifier 

base

.

NOTE − It may be easier to remove the frame by
pulling on the 

tabs 

one at a time.

7 − Unsnap the 

pad assembly frame

 from the sides of

the 

distribution tray

. Remove the 

distribution tray

from the 

pad assembly frame

. Remove the 

tray

cover

 by pulling it straight off of the 

distribution tray

.

Lightly scrape off any mineral deposits from the
surface of the 

distribution tray

.

8 − Slide the 

humidifier pad

 out of the frame. Twist and

flex the frame to loosen the calcium deposits on the
frame or use a putty knife to clean the frame. Replace
the 

humidifier pa

d annually or more frequently if

necessary. Slide the pad into the frame with the black
mark facing up. Snap the 

tray cover

 onto the

distribution tray

. Snap the 

distribution tray

 back

into place.

9 − Position the 

pad assembly frame

 so that the 

tabs

are pointing outward. Align the drain extension on the
pad assembly with the 

drain spud

 in the humidifier

base. Reinsert the 

pad assembly frame

 in the 

base

.

Push the 

pad assembly frame

 in at the top until it

snaps into place.

10 −Remove  the 

drain hose

 from the bottom of the

humidifier. Bend and flex the hose to loosen the
internal calcium deposits. Flush the hose with water
under pressure and slip it back onto the 

drain spud

.

The 

drain hose

 should have a constant downward

slope and must not be flattened or blocked.

11− Reinstall the 

front cover

 by hooking at the top of

base

 and latching at the bottom.

12− Reconnect the control harness. Make sure that the

plug snaps into place.

13− Reconnect electrical power and turn on water supply.
14− Check humidifier operation:

Manual Humidistat −

 Adjust humidistat to highest

setting and make sure the furnace blower is
operating. Check the humidifier for leaks during
operation. Adjust, if necessary.

Universal Humidistat −

 Check system operation by

setting the knob to 

TEST

. With furnace blower

operating and furnace calling for heat, humidifier will
operate for one minute.  Press the 

RESET 

button on

the side of the control to reset the Change Humidifier
Pad" indicator. Check the humidifier for leaks during
operation. Adjust, if necessary.

15− Set manual humidistat or universal humidistat to its

original position.

FIGURE 6

HCWP2 Humidifier Parts Identification

FRONT COVER

BASE

HUMIDIFIER

PAD

(Black mark

facing up)

SOLENOID

VALVE

DISTRIBUTION

TRAY

PAD ASSEMBLY

FRAME

DRAIN HOSE

POWER CORD

TABS

DRAIN SPUD

LATCH

CONTROL HARNESS TAB

TRAY COVER