Page 2
SPECIFICATIONS
Gas
Heating
Performance
ModelNo.
G71MPP
−36B−070
G71MPP
−36C−090
G71MPP
−60C−090
G71MPP
−60C−110
G71MPP
−60D−135
Maximum
Input− Btuh
66,000
88,000
88,000
110,000
132,000
Output− Btuh
60,000
81,000
81,000
103,000
123,000
Temperature rise range −
_
F
50 − 80
60 − 90
50 − 80
50 − 80
55 − 85
Gas Manifold Pressure (in. w.g.)
Natural Gas / LPG/Propane
3.5 / 10.0
3.5 / 10.0
3.5 / 10.0
3.5 / 10.0
3.5 / 10.0
Minimum
Input − Btuh
26,000
35,000
35,000
44,000
53,000
Output − Btuh
25,000
34,000
34,000
42,000
51,000
Temperature rise range −
_
F
40 − 70
40 − 70
40 − 70
40 − 70
40 − 70
Gas Manifold Pressure (in. w.g.)
Natural Gas / LPG/Propane
0.7 / 2.0
0.7 / 2.0
0.7 / 2.0
0.7 / 2.0
0.7 / 2.0
1
AFUE
95.0%
95.0%
95.0%
95.0%
95.0%
Highstatic(CSA)− in.w.g.
.80
.80
.80
.80
.80
Connections
in.
Intake / Exhaust Pipe (PVC)
2 / 2
2 / 2
2 / 2
2 / 2
3 / 3
Condensate Drain Trap (PVC pipe) − i.d.
1/2
1/2
1/2
1/2
1/2
with field supplied (PVC coupling) − o.d.
3/4
3/4
3/4
3/4
3/4
hose with hose clamp − i.d. x o.d.
1 x 1−1/4
1 x 1 1/4
1 x 1 1/4
1 x 1 1/4
1 x 1 1/4
GaspipesizeIPS
1/2
1/2
1/2
1/2
1/2
Indoor
Blower
Wheelnominaldiameter xwidth −in.
10 x 8
10 x 10
11−1/2 x 10
11−1/2 x 10
11−1/2 x 10
Motoroutput − hp
1/2
1/2
1
1
1
Tons ofadd−oncooling
2 − 3.5
2 − 3.5
3.5 − 5
3.5 − 5
3.5 − 5
Air volume range − cfm
250 −1395
250 − 1395
450 − 2215
450 − 2210
450 − 2190
ShippingData
lbs. − 1 package
149
160
171
184
206
Electricalcharacteristics
120 volts − 60 hertz − 1 phase (less than 12 amps)
NOTE − Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non−weatherized furnaces.