TABLE 17
G61MPVT−60C−090 BLOWER MOTOR PERFORMANCE (LESS FILTER)
0.0" to 0.8" w.g. (0 through 200 Pa) External Static Pressure Range
Factory Settings: Heating Speed − 2; Cooling Speed − 4; Speed Adjust − NORM.
Return Air Options: Single side return with optional RAB return air base
ADJUST"
Switch
Positions
Speed Switch Positions
Second Stage HEAT" Speed
Second Stage COOL" Speed
1
2
3
4
1
2
3
4
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1440
680
1630
770
1810
855
2015
950
1525
720
1655
780
1860
880
2100
990
NORM
1300
615
1485
700
1655
780
1830
865
1385
655
1500
710
1695
800
1905
900
1155
545
1310
620
1480
700
1640
775
1240
585
1320
625
1510
710
1695
800
ADJUST"
Switch
Positions
First Stage HEAT" Speed
First Stage COOL" Speed
1
2
3
4
1
2
3
4
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1320
625
1490
700
1665
785
1840
870
1060
500
1135
535
1285
605
1455
685
NORM
1180
555
1345
635
1515
715
1680
795
960
455
1035
490
1165
550
1310
620
1055
500
1180
560
1340
630
1490
705
865
405
920
435
1050
495
1165
550
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91%
of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70
%
of the same second stage COOL speed position.
Continuous Fan Only speed is approximately
38%
of the same second stage COOL speed position − minimum 500 cfm (235 L/s).
TABLE 18
G61MPVT−60C−110 BLOWER MOTOR PERFORMANCE (LESS FILTER)
0.0" to 0.8" w.g. (0 through 200 Pa) External Static Pressure Range
Factory Settings: Heating Speed − 2; Cooling Speed − 4; Speed Adjust − NORM.
Return Air Options: Bottom; both sides; or bottom and one side.
ADJUST"
Switch
Positions
Speed Switch Positions
Second Stage HEAT" Speed
Second Stage COOL" Speed
1
2
3
4
1
2
3
4
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1505
710
1710
805
1915
905
2130 1005 1625
770
1745
825
1990
940
2210 1045
NORM
1370
645
1565
740
1765
835
1945
920
1465
690
1580
745
1790
845
1995
940
1205
570
1380
650
1565
740
1740
820
1290
610
1405
660
1605
760
1790
845
ADJUST"
Switch
Positions
First Stage HEAT" Speed
First Stage COOL" Speed
1
2
3
4
1
2
3
4
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1370
645
1570
740
1760
830
1945
920
945
445
1020
480
1160
545
1300
615
NORM
1235
585
1420
670
1600
755
1780
840
840
395
910
430
1055
500
1180
555
1105
525
1250
590
1420
670
1580
745
740
350
800
380
920
435
1045
495
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91%
of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70
%
of the same second stage COOL speed position.
Continuous Fan Only speed is approximately
38%
of the same second stage COOL speed position − minimum 500 cfm (235 L/s).