Servicing the Filter
Inspect and clean air filters each month. Filters must
be cleaned when dirty to assure proper furnace opĆ
eration and maintain efficiency.
A-Cleaning Reusable Foam Filter
1- Turn off electrical power to furnace.
2- Remove blower access panel. Wait for blower to stop.
3- Remove filter by sliding up and out of channel.
4- Wash filter with water and a mild detergent. For inĆ
creased efficiency, filter media should be sprayed with
Filter Handicoater when dry. Filter Handicoater is RP
products No. 418 and is available as Lennox part No.
P-8-5069. See table 1 for replacement filters.
TABLE 1
G21 Model No.
Filter Size
Filter Part
No.
All Q-40,-60,
Q3-80, Q4-80 and
V3-60, -80 units
16" x 25"
(406 x 635mm)
P-8-7822
Q5-80 and all
Q-100 units: and
V5-80,-100 units
20" x 25"
(508 x 635mm
)
P-8-7831
5- Reinstall filter. Slide filter into top channel and drop
into lower channel.
IMPORTANT-Do not replace foam reusable filters
with throw-away type filters.
6- Replace blower access panel.
Lubrication
Motors are prelubricated for extended bearing life; no
further lubrication is required.
Service
At the beginning of each heating season, the system
should be checked as follows:
1- Examine the termination ends of the intake and exĆ
haust lines for obstructions or blockages.
2- Check the intake and exhaust lines for holes, sagĆ
ging or broken isolation hangers. If a sag is found in
either line, raise the line and support it with an isolaĆ
tion hanger. Replace any damaged isolation hangĆ
ers.
3- The return air duct connection should be sealed to
the furnace casing and terminate outside the space
containing the furnace.
4- Check the physical support of the furnace. It should
be sound without sagging, cracks, gaps, etc., around
the base so as to provide a seal between the support
and the base.
5- Check that there is no obvious signs of deterioration
of the furnace.
6- Inspect and clean condensate drain system for free
flow of condensate.
IMPORTANT-If a change in the sound level of the unit
is detected or there is evidence of condensate leakĆ
age around the unit, contact your Lennox service
technician.