Page 4
BLOWER DATA
EL296DF045XV36B BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
910
1150
+18%
855
1095
+12%
820
1040
+6%
770
990
Factory Default
745
935
–6%
700
880
–12%
665
820
–18%
635
755
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low Medium-High
2
High
Low
Medium-Low Medium-High
2
High
+
640
755
850
975
895
1050
1210
1360
Factory Default
580
695
780
880
805
965
1105
1250
–
545
645
720
795
735
865
1000
1130
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 250 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 250 cfm.
EL296DF045XV36B BLOWER MOTOR WATTS (COOLING)
1
Cooling Speed
DIP Switch
Settings
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
Second Stage
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
+ Setting
Cooling
Speed
Low
28
44
60
77
93
112
128 144 158 59
77
97
121
138
160
182 197
216
241 256
Med-low 47
67
88 105
121
138
161
179
201
131 154 177
202
228 250 277
299
320 344 370
Med-High
69
91
113 132
160
183 204
220
246
199
215 248 275 308 340 360 390 407 431 445
High
100
117 153 172
192
215 240
260
286
292
313 363 379 419 452 488 511 526 523 524
Factory Default
Cooling
Speed
Low
17
34
52
65
82
97
121
132 148
61
79
98 125 141 164 185
201 219
246 259
Med-low 35
50
70
85 105 125 140 155 175
99
115 148 167 188
211
236 256 279 303 317
Med-High 54
72
95 113 131 148 173 189
210
147 170 197 223 252 278 301 330 355 373 398
High
74
96
118 141 168
190 212
233 252
216 229
258 303 325 356 390 410 426 448 465
– Setting
Cooling
Speed
Low
17
31
49
61
75
91
107 123 136 46
64
82
101
115 134 155 174
196
205
221
Med-low 28
45
61
77
93
112 129
144 159 72
92
114 133
160
184 204
221
247 263 282
Med-High 40
57
77
93
112
130 148 165 186
112
130
161
183 205
226
252 272 294 319 341
High
57
76
97
119
136 156 179 195 214 155 174 207 235 265
292
311 343 370 386 414