Page 26
TABLE 12 Continued
Maximum Allowable Intake or Exhaust Vent Length in Feet
NOTE - Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total.
Both Intake and Exhaust must be same pipe size.
NOTE - additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the
total vent length calculation.
Concentric Termination at Elevation 0 - 4500 ft
No.
Of 90°
Elbows
1-1/2” Pipe
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
Model
030 045 070 090 110 030
045 070 090 110
030
045 070 090 110
030
045 070 090 110
1
20
15
10
n/a
n/a
73
58
42
22
105
105
89
54
121
121
114
114
2
15
10
n/a
68
53
37
17
100
100
84
49
116
116
109
109
3
10
n/a
63
48
32
12
95
95
79
44
111
111
104
104
4
n/a
58
43
27
n/a
90
90
74
39
106
106
99
99
5
53
38
22
85
85
69
34
101
101
94
94
6
48
33
17
80
80
64
29
96
96
89
89
7
43
28
12
75
75
59
24
91
91
84
84
8
38
23
n/a
70
70
54
19
86
86
79
79
9
33
18
65
65
49
14
81
81
74
74
10
28
13
60
60
44
n/a
76
76
69
69
Concentric Termination Elevation 4500 - 10,000 f
t
No.
Of 90°
Elbows
1-1/2” Pipe
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
Model
030 045 070 090 110 030
045 070 090 110
030
045 070 090 110
030
045 070 090 110
1
20
15
10
n/a
n/a
73
58
42
n/a
105
105
89
54
121
121
114
114
2
15
10
n/a
68
53
37
100
100
84
49
116
116
109
109
3
10
n/a
63
48
32
95
95
79
44
111
111
104
104
4
n/a
58
43
27
90
90
74
39
106
106
99
99
5
53
38
22
85
85
69
34
101
101
94
94
6
48
33
17
80
80
64
29
96
96
89
89
7
43
28
12
75
75
59
24
91
91
84
84
8
38
23
n/a
70
70
54
19
86
86
79
79
9
33
18
65
65
49
14
81
81
74
74
10
28
13
60
60
44
n/a
76
76
69
69