THIS MANUAL MUST BE LEFT WITH THE 

HOMEOWNER FOR FUTURE REFERENCE

 WARNING

Improper installation, adjustment, alteration, service 

or maintenance can cause property damage, personal 

injury or loss of life. Installation and service must  be 

performed by a licensed professional HVAC installer or 

equivalent, service agency, or the gas supplier.

 CAUTION

As with any mechanical equipment, contact with sharp 

sheet metal edges can result in personal injury. Take 

care while handling this equipment and wear gloves and 

protective clothing.

Shipping and Packing List 

Package 1 of 1 contains: 
1 – Assembled electric heat section 
1 – Bag assembly containing the following: 
        6 – Screws 
        1 – Wiring diagram 
        Circuit breaker cover - 1 each 
1 – Transformer (575V, 3-phase, 60Hz only) 
1 –  Fuse block extension plate (460V, 3-phase, 60Hz and 

575V, 3-phase, 60Hz only)

2 – Adhesive-backed foam seals 
1 – Circuit breaker cover
Check equipment for shipping damage; if found, immedi-

ately contact the last carrier. 

INSTALLATION 

INSTRUCTIONS

ELECTRIC HEAT SECTIONS

507855-01

7/2019

ECB27 Series Units

 WARNING

Electric shock hazard! - Disconnect all power 

supplies before servicing.
Replace all parts and panels before 

operating.
Failure to do so can result in death or 

electrical shock.

Electric Heat Section

The ECB27 series electric heat section provides field-in

-

stalled electric heat for various air handler units. These 

electric heat sections are available in either single- or 

three-phase. Single-phase heat sections are equipped 

with either terminal blocks or circuit breakers.

Refer to the model-specific air handler product specifica

-

tion bulletin for heat section applications.

General Information

These instructions are a general guide and do not su-

persede local codes. Local authorities having jurisdiction 

should be consulted before installation. Read these in-

structions thoroughly before starting installation. 
Be sure to disconnect all power to the unit before you in-

stall and service this equipment. Use proper tools and pro-

tective equipment during installation and service. 
Installation of air handler with or without optional electric 

heat must conform with standards in the National Fire 

Protection Association (NFPA) Standard for Installation of 

Air Conditioning and Ventilation Systems NFPA No. 90A, 

and Standard for Installation of Resident Type Warm Air 

Heating and Air Conditioning System, No. 90B, the man-

ufacturer’s installation instructions, and local municipal 

building codes.

Summary of Contents for ECB27 Series

Page 1: ...ing Replace all parts and panels before operating Failure to do so can result in death or electrical shock Electric Heat Section The ECB27 series electric heat section provides field in stalled electr...

Page 2: ...vided in the bag assembly Cabinet Modifications for 460 Volt 3 Ton Models Modifications are necessary when an ECB27 10F G 15F G voltage 460 volt electric heat section is installed in a 460 volt 3 ton...

Page 3: ...plate for the specific size of electric heat section that you are installing Discard the unused piece of patch plate see figures 5 and 6 6 Secure the patch plate on the air handler access door IN DOW...

Page 4: ...B ECB27 5CB ECB27 6CB ECB27 8CB ECB27 9CB ECB27 12 5CB ECB27 15CB ECB27 20CB ECB27 25CB ECB27 10CB 3 Ph ECB27 15CB 3 Ph ECB27 20CB 3 Ph ECB27 25CB 3 Ph SIDE OF UNIT DISCARD BREAK AT THIS POINT DISCARD...

Page 5: ...ith 1 1 2 inch trade size 1 31 32 inch diameter conduit A conduit reducer washer has been provided if you are installing a smaller sized conduit For single point power supply refer to the nameplate on...

Page 6: ...using ECB27 heat section adjust the blower speed according to the size of electric heat and air handler unit The minimum blower setting for each air handler size with any heat sections in any applicat...

Page 7: ...PHASE ELECTRIC HEATERS ONLY STATS Y2 USED ONLY WHEN TWO SPEED COMPRESSOR IS USED HP21 COMMON USED ONLY ON SOME THERMOSTATS USING SERVICE LIGHT OPTION S54 WITH SOME ELECTRONIC THERMOSTATS MAY REQUIRE...

Page 8: ...Page 8 Unit Field Wiring Diagrams FIGURE 13 Typical Unit Diagram Air Handlers with Constant Torque Motors P Voltage 208 230V 1 Phase 60Hz...

Page 9: ...Page 9 FIGURE 14 Typical Unit Diagram Air Handlers with PSC Non Communicating Motors P Voltage 208 230V 1 Phase 60Hz...

Page 10: ...Page 10 FIGURE 15 Typical Unit Diagram Air Handlers with Variable Speed Communicating Motors P Voltage 208 230V 1 Phase 60Hz...

Page 11: ...Page 11 FIGURE 16 Typical Unit Diagram Air Handlers with Constant Torque Motors G Voltage 460V 3 phase 60Hz...

Page 12: ...ECB27 5 CB P 538002 01 ECB27 6 CB P 538002 01 ECB27 8 CB P 538003 01 ECB27 9CB P 538004 01 ECB27 12 5CB P 538005 01 ECB27 15CB P 538005 01 ECB27 20CB P 538006 01 ECB27 25CB P 538010 01 ECB27 8 Y 53800...

Reviews: