Product Reference Information

Cat.

No.

Fireplace

Model

Ship.

Wt.

Ship.

Volume

H4793

LSM40MN-2

261 lb.

45.8 cu. ft.

H4794

LSM40MP-2

268 lb.

45.8 cu. ft.

H4797

LSM40EN-2

307 lb.

57.1 cu. ft.

H4795

LSM45MN-2

307 lb.

57.1 cu. ft.

H4796

LSM45MP-2

307 lb.

57.1 cu. ft.

H4798

LSM45EN-2

307 lb.

57.1 cu. ft.

Digital Wall Thermostat

The wall thermostat kit provides temperature control 

for optimum comfort.

Wall Thermostat, Millivolt

Cat. No.

Model No.

Description

H4635

DWTK

Wall Thermostat Kit, 

White

ACCESSORY COMPONENTS

ON/OFF Wall Switch Kit

The ON/OFF wall switch kit may be used to control the 

operation of the fireplace burner as an alternative to 

the unit mounted ON/OFF switch. Install the ON/OFF 

wall switch in a convenient location near the fireplace.

ON/OFF Wall Switch Kit

Cat. No.

Model

Description

85L87

FWSK

Wall Switch

Standard Remote Control System 

The Model RCL (Standard) Remote Control System, 

features a simplistic OFF/ON control function for the 

fireplace.  This model includes a hand-held transmitter, 

a remote receiver with wall-mount cover plate and 

all hardware required to install the unit.  The remote 

receiver can be wall or hearth mounted.
The transmitter has ON and OFF functions that are 

activated by  pressing either  button  on  the  face  of 

the  transmitter.  When  a  button  on  the  transmitter 

is pressed, a signal light illuminates briefly to verify 

that a signal has been sent.
The Model RCL is designed to operate with all mil-

livolt ignition systems, as well as electronic ignition 

systems.  It  may  be  installed  with  use  for  either 

natural  gas  or  propane  gas  appliances.  The  RCL 

offers ease of installation and allows you to execute 

on-off commands to the fireplace effortlessly with 

one simple motion.
The Model RCL comes complete with detailed operat-

ing instructions.

Flame Modulating Remote Control

Flame Modulating Remote Controls were developed 

to provide a safe, reliable and user-friendly remote 

control system for appliances equipped with a Millivolt 

Gas Valve.  A detailed set of instructions are included 

with each remote.

(ref. Instruction P/N 750130M)

Bag of Glowing Embers
Bag of Volcanic Stone
Bag of Vermiculite

Replacement  ember  material,  volcanic  stone  and 

vermiculite are available for use with these appliances. 

Order them to replace materials as part of the periodic 

maintenance of the appliance. 

Firebox Accessories

Cat. No.

Model

Description

88L53

FGE

Bag of Glowing Embers

80L42

FDVS

Bag of Volcanic Stone

H6319

--

Bag of Vermiculite

(FDVS Instruction P/N 750010M)

Remote Control Kit, Standard

Cat. No.

Model No.

Description

H0249

RCL

Remote Control System  

(Standard)

(ref. Instruction P/N 750127M)

Flame Modulating Remote Control Kits

Cat. No.

Model No.

Description

H0301

RCL-MN

Natural Gas

H0302

RCL-ML

Propane Gas

Touch-Up Paint Kit

Repair of minor scratches and 

discoloration of the appliances 

black painted surfaces may be 

accomplished with the touch-up 

paint kit.

Touch-Up Paint (Black) Kit

Cat. No.

Model

Description

90L73

FTPK-B

Black Paint Kit

PA I N T

(ref. Instruction P/N 750050M)

Summary of Contents for Dave Lennox Signature Montebello LSM40EN-2

Page 1: ...ry or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROI...

Page 2: ...ts fireplace get EXTREMELY HOT Table of Contents Safety and Your Fireplace 2 Important Safety Information 4 Attaching the Safety in Operation Warnings 5 General Information 6 Maintenance 9 Front Glass...

Page 3: ...page 5 Lisez la section Informations importantes relatives la s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica...

Page 4: ...tits les jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent...

Page 5: ...la y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de...

Page 6: ...dassupple mentalheaters Therefore itisadvisable to have an alternate primary heat source when installed in a dwelling Appliance Installation Service and Maintenance Notices IMPORTANT Improper installa...

Page 7: ...ust gases are vented through the same direct vent co axial intake exhaust vent system The Millivolt appliances are designed to oper ate on either natural or propane gas and have a millivolt gas contro...

Page 8: ...nt Access Note Topreventexcessiveresistanceinburner circuit whichcancauseburneroperationprob lems only one burner control switch should be wired to valve Variable Flame Height Adjustment Millivolt And...

Page 9: ...meandsafecombustion Inspect Wiring Refer to wiring diagrams on Page 15 CAUTION Label all wires prior to discon nection when servicing controls Wiring errorscancauseimproperanddangerous operation Verif...

Page 10: ...the gasket seats evenly as the door draws shut Engage the nut insert and fasten with two screws to secure the door 4 Installthedoormodestyshieldontopflange glassdoorasfollows grabthedoormodesty shiel...

Page 11: ...rs of log sets Figure 5 Figure 6 Glowing Embers Rockwool For Propane Gas Only Do Not Place Embers On Main Ports Figure 7 LSM45 2 Shown Mixture Of Volcanic Stone And Vermiculite WARNING DO NOT attempt...

Page 12: ...With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Align Hole At Bottom Of Log 5 Over The Pin On Log 2 Engage Log 7 With The Pin On Log 4 6 5 7 1 2 4 LSM40 2 LSM45 2 Log Plac...

Page 13: ...ntering the air shutter opening To achieve a warm yellowish orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment G...

Page 14: ...ING Air shutter adjustment should only be performed by a quali fied professional service technician Ensure that the front glass door assembly is in place and sealed After adjustment Figure 15 Main Bur...

Page 15: ...A complete parts list is found at the end of this manual Use only parts supplied from the manufacturer Withpropercareandmaintenance yourappli ance will provide many years of enjoyment If you should e...

Page 16: ...gnal light illuminates briefly to verify that a signal has been sent The Model RCL is designed to operate with all mil livolt ignition systems as well as electronic ignition systems It may be installe...

Page 17: ...SSION Andiron Door Kits Fits Fireplace Models Catalog No Model Mission Classic LSM40 2 LSM45 2 H2227 AKM LSM H2228 AKC LSM ref Instruction P N 750183M Barrier Screen Kits These Barrier Screen Panel ki...

Page 18: ...es after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 8 If knob does not pop up when released stop and immediately call your serv...

Page 19: ...onc Allumez imm diatement la veilleuse en d clenchant l allume gaz tincelle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pen dant environ 9...

Page 20: ...e wall switch to OFF or set the thermostat to the lowest setting if applicable 2 Turn the ON OFF switch to OFF if Step 1 is not applicable 3 Close the main line shut off valve TO TURN OFF GAS TO APPLI...

Page 21: ...d arr t OFF ou plaez le thermostat plssible si requis 3 Tournezl interrupteur marche arr t laposition arr t Off si l etape 2 est appropriee Cet interrupteur marche arr t devrait toujours tre en posit...

Page 22: ...ioncan be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in pla...

Page 23: ...t note below IMPORTANT NOTE If an optional remote switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remot...

Page 24: ...ires to valve Ensure blue and white 2 wires connection is secure to valve D Air in the gas line Purge gas line of air E Low voltage Test voltage at AC terminals of module for 24 VAC If no voltage repl...

Page 25: ...k Liner Kit f Black H2219 H4801 H2220 H4803 H2221 H2222 1 1 1 1 1 1 H2223 H4802 H2224 H4804 H2225 H2226 1 1 1 1 1 1 2 Door Modesty Shield H4808 1 H4809 1 3 Log Set Oak H4799 1 H4799 1 3 Log Set Birch...

Page 26: ...8 8 6 5 9 17 12 4 14 13 HI LO 11 10 22 21 20 15 23 24 25 19 1 1 3 2 1 1 Rustic Pattern Shown NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO DV GAS FIREPLACES LSM40 45MN...

Page 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO DV GAS FIREPLACES LSM40 45MN 2 LSM40 45MP 2 LSM40 45EN 2 CARE AND OPERATION INSTRUCTIONS Notes...

Page 28: ...TIONS Printed in U S A 2005 2011 Lennox Hearth Products P N 875027M Rev H 06 2011 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specification...

Reviews: