background image

12

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Figure 8

Align Groove At The Bottom Of Log (2) Over 

The Grate And Push It Towards The Rear.

2

Align Two Holes At Bottom Of Log (1) 

Over The Pins On The Gas Burner.

Engage Logs (3 & 4) With The Grate Pins And Align Groves At 

The Bottom Of The Logs Over The Grate.

4

3

Engage Log (6) With The Grate Pin 

And Align Groove At The Bottom Of 

The Log Over The Grate.

Align Hole At Bottom Of Log (5) 

Over The Pin On Log (2).

Engage  Log  (7)  With 

The Pin On Log (4).

6

5

7

1

2

4

LSM40-2 & LSM45-2 Log Placement

3

2

4

1

6

5

7

Log Number

Description

1

Log, Center

2

Log, Rear

3

Log, Center/Left

4

Log, Center/Right

5

Log, Rear/Top

6

Log, Front/Left

7

Log, Front/Center

Figure 9

Figure 10

Figure 11

Figure 12

LENNOX HEARTH PRODUCTS  •  MONTEBELLO

® 

 DV GAS FIREPLACES 

(LSM40/45MN-2, LSM40/45MP-2, LSM40/45EN-2)

  •  CARE AND OPERATION INSTRUCTIONS

Summary of Contents for Dave Lennox Signature Montebello LSM40EN-2

Page 1: ...ry or death WARNING AVERTISSEMENT AVISO HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROI...

Page 2: ...ts fireplace get EXTREMELY HOT Table of Contents Safety and Your Fireplace 2 Important Safety Information 4 Attaching the Safety in Operation Warnings 5 General Information 6 Maintenance 9 Front Glass...

Page 3: ...page 5 Lisez la section Informations importantes relatives la s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica...

Page 4: ...tits les jeunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent...

Page 5: ...la y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de...

Page 6: ...dassupple mentalheaters Therefore itisadvisable to have an alternate primary heat source when installed in a dwelling Appliance Installation Service and Maintenance Notices IMPORTANT Improper installa...

Page 7: ...ust gases are vented through the same direct vent co axial intake exhaust vent system The Millivolt appliances are designed to oper ate on either natural or propane gas and have a millivolt gas contro...

Page 8: ...nt Access Note Topreventexcessiveresistanceinburner circuit whichcancauseburneroperationprob lems only one burner control switch should be wired to valve Variable Flame Height Adjustment Millivolt And...

Page 9: ...meandsafecombustion Inspect Wiring Refer to wiring diagrams on Page 15 CAUTION Label all wires prior to discon nection when servicing controls Wiring errorscancauseimproperanddangerous operation Verif...

Page 10: ...the gasket seats evenly as the door draws shut Engage the nut insert and fasten with two screws to secure the door 4 Installthedoormodestyshieldontopflange glassdoorasfollows grabthedoormodesty shiel...

Page 11: ...rs of log sets Figure 5 Figure 6 Glowing Embers Rockwool For Propane Gas Only Do Not Place Embers On Main Ports Figure 7 LSM45 2 Shown Mixture Of Volcanic Stone And Vermiculite WARNING DO NOT attempt...

Page 12: ...With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Align Hole At Bottom Of Log 5 Over The Pin On Log 2 Engage Log 7 With The Pin On Log 4 6 5 7 1 2 4 LSM40 2 LSM45 2 Log Plac...

Page 13: ...ntering the air shutter opening To achieve a warm yellowish orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment G...

Page 14: ...ING Air shutter adjustment should only be performed by a quali fied professional service technician Ensure that the front glass door assembly is in place and sealed After adjustment Figure 15 Main Bur...

Page 15: ...A complete parts list is found at the end of this manual Use only parts supplied from the manufacturer Withpropercareandmaintenance yourappli ance will provide many years of enjoyment If you should e...

Page 16: ...gnal light illuminates briefly to verify that a signal has been sent The Model RCL is designed to operate with all mil livolt ignition systems as well as electronic ignition systems It may be installe...

Page 17: ...SSION Andiron Door Kits Fits Fireplace Models Catalog No Model Mission Classic LSM40 2 LSM45 2 H2227 AKM LSM H2228 AKC LSM ref Instruction P N 750183M Barrier Screen Kits These Barrier Screen Panel ki...

Page 18: ...es after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 8 If knob does not pop up when released stop and immediately call your serv...

Page 19: ...onc Allumez imm diatement la veilleuse en d clenchant l allume gaz tincelle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pen dant environ 9...

Page 20: ...e wall switch to OFF or set the thermostat to the lowest setting if applicable 2 Turn the ON OFF switch to OFF if Step 1 is not applicable 3 Close the main line shut off valve TO TURN OFF GAS TO APPLI...

Page 21: ...d arr t OFF ou plaez le thermostat plssible si requis 3 Tournezl interrupteur marche arr t laposition arr t Off si l etape 2 est appropriee Cet interrupteur marche arr t devrait toujours tre en posit...

Page 22: ...ioncan be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in pla...

Page 23: ...t note below IMPORTANT NOTE If an optional remote switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remot...

Page 24: ...ires to valve Ensure blue and white 2 wires connection is secure to valve D Air in the gas line Purge gas line of air E Low voltage Test voltage at AC terminals of module for 24 VAC If no voltage repl...

Page 25: ...k Liner Kit f Black H2219 H4801 H2220 H4803 H2221 H2222 1 1 1 1 1 1 H2223 H4802 H2224 H4804 H2225 H2226 1 1 1 1 1 1 2 Door Modesty Shield H4808 1 H4809 1 3 Log Set Oak H4799 1 H4799 1 3 Log Set Birch...

Page 26: ...8 8 6 5 9 17 12 4 14 13 HI LO 11 10 22 21 20 15 23 24 25 19 1 1 3 2 1 1 Rustic Pattern Shown NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO DV GAS FIREPLACES LSM40 45MN...

Page 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE LENNOX HEARTH PRODUCTS MONTEBELLO DV GAS FIREPLACES LSM40 45MN 2 LSM40 45MP 2 LSM40 45EN 2 CARE AND OPERATION INSTRUCTIONS Notes...

Page 28: ...TIONS Printed in U S A 2005 2011 Lennox Hearth Products P N 875027M Rev H 06 2011 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specification...