background image

User Guide

Color Touchscreen
Programmable Residential
Thermostat

ComfortSense

®

 5500

Model: 13H13
507500-01
10/2015
Supersedes 7/2015

Summary of Contents for ComfortSense5500

Page 1: ...User Guide Color Touchscreen Programmable Residential Thermostat ComfortSense 5500 Model 13H13 507500 01 10 2015 Supersedes 7 2015 ...

Page 2: ...shows the current and set temperatures and time S Ergonomic design S Smooth Set Recovery starts system early to achieve setpoint at start of program period S Compressor short cycle protection 5 minutes S Real time clock keeps time during power failures and automatically adjusts for daylight savings time and leap year S Program hold options allow user to override the program schedule as desired by ...

Page 3: ...l This object will be blue in color C This is the location where no system demand will be active In figure 1 the example would be any temperature between 73 F and 77 F D When there is an active call for heating this area of the dial will fade back and forth from white to red E When there is an active call for cooling this area of the dial will fade back and forth from white to blue F The yellow li...

Page 4: ...4 Home Screen 2 31 am heat to cool to inside schedule 1 away 62 76 X 0 Ⓒ Ⓑ Ⓘ Ⓐ Ⓔ Ⓕ Ⓖ Ⓗ Ⓓ Ⓔ Ⓕ 78 waiting Schedule hold until 12 30 pm Figure 2 Home Screen ...

Page 5: ...ions performance report edit schedulesand settings screens E Touch the heating set point indicator to set the heat to if enabled temperature Touching either the heating set point indicator or heat to will display the temperature setting detail screen see figure 3 Use the and icons to adjust the temperature setting The temperaturedial will change from white to red when heating is active F Touch the...

Page 6: ...splayed icons will indicate cooling or heating demand cooling compressor delay or cooling demand I This icon and the text that follows it indicate that the schedule is on hold either until the next time period or permanently 1 Place the schedule on hold by touching on either the heat to or cool to location on the main screen If an adjustment is required for the temperature setting this can be done...

Page 7: ...permanent schedule hold touch the Ⓧ icon NOTE For the 1 or 2 hour setting the home screen will indicate schedule hold until time indicated i e 11 57 pm NOTE When in any hold status the mode status area on the screen will go to the current status mode For example from schedule 1 to heat cool J System Status Icons Equipment operation information appears along the left side of the home screen to indi...

Page 8: ...ign indicates that the system is running in emergency heat mode The schedule icon indicates that the system is transitioning to the next scheduled temperature setting This icon will only appear if smooth setback recovery is enabled during installer setup When enabled the system will begin recovery up to two hours before the programmed time to reach the programmed temperature at the programmed even...

Page 9: ...9 Accessing Mode Screen Touch the screen in the area indicated below to access the mode screen 2 31 am heat to cool to 78 inside schedule 1 away 72 78 0 Figure 4 Home Screen Accessing Mode Screen ...

Page 10: ...LATE Three fan operation modes are available ON AUTO and CIRCULATE A green check mark indicates the selected setting FAN OPERATION In the CIRCULATE mode the user can cycle the fan for a programmed period of operation each hour during periods when the heating or cooling equipmentis not running Table 2 Fan Operation on Fan is NOT following the schedule and runs continuously until it is changed from ...

Page 11: ...corner of the screen to access the menu Selectable options under menu are notifications performance report edit schedules and settings menu performance report notifications 13 edit schedules settings heat to cool to 72 78 8 0 ool Figure 5 User Menu Screen ...

Page 12: ... or set a future reminder Active notifications are listed under settings notification If critical errors occur they are also displayed undernotifications as illustrated in figure 6 Touch the contractor information option for assistance Reminders are displayed under notifications as illustrated in figure 7 Choose to either clear the reminder or remind later to receive another notificationafter 1 da...

Page 13: ... to Clear Recovery Condition 12 replace media filter reminder Touch either done to clear the reminder or remind later button 13 replace UV lamp 14 replace humidity pad 15 routine system check up 16 replace metal insert for pure air 17 user editable 18 user editable ...

Page 14: ...Screen From the HOME screen touch the MENU and touch edit schedules option NOTE See Select Modes on page 9 to select and run a specific schedule The edit schedules screen provides access to as many as three separate schedules Each schedule can be renamed and edited See figures 8 and 9 NOTE If a fan mode is selected under the select mode screen it will override any scheduled fan setting For example...

Page 15: ...l heat only cool only Individual days Monday Tuesday Wednesday Thursday Friday Saturday Sunday wake leave home night Week weekend week weekend all7 days All days wake rename time cool to heat to fan time select time or delete period If period deleted select fan mode on auto circulate cool to and or heat to Amaximum offourtime periods can beused Ifany timeperiods aredeleted anoptiontoadd a time per...

Page 16: ...Setting Options User Settings Selection Descriptions Tables4 through 7 provides information for options that can be selected for each setting Table 4 User Settings Fan Setting Selection Function Description fan on auto and circulate See table 2 on page 10 for fan operation de tails When selecting circulate you can set the circulate off time from 1 to 30 minutes ...

Page 17: ...home to desired tempera ture setting Options are on or off set point range Heating limit with a default of 90 F Range is 45 F to 90 F Cooling limit with a default of 45 F Range is 45 F to 99 F cool only option only appears if no heating equipment is avail able or configured set point range Cooling limit with a default of 45 F Range is 45 F to 99 F ...

Page 18: ...e digit code Partial lock restricts access to menu To set locked option create a three digit code This is a complete lock which restricts access to anything on the screen NOTE Partially Locked and Locked settings are for one instance only Either lock must be set each time you wish to partially lock or completely lock the screen If the custom ac cess code is forgotten the master code to un lock the...

Page 19: ...inside temperature and outside temperature if outdoor sensor is installed and enabled are displayed on the screen Touch the screen to restore all other details The backlight setting is on the screen saver menu Options are continuous on or energy save Default setting is continuous on screen brightness A horizontal bar is provided to adjust brightness from minimum to maximum temperature scale Select...

Page 20: ...edule Edit 14 Schedule Hold 7 Schedules 10 Screen Lock Locked 18 Partially 18 Select Modes 10 System Status Icons 8 T Temperature Dial Indicator 3 U User Settings 16 17 Cool Only 17 Set Point Range 17 Display 19 Clean Screen 19 Outdoor Temperature Display 19 Screen Brightness 19 Screen Saver 19 Temperature Scale 19 Fan 16 General 18 About 18 Date Time 18 Language 18 Screen Lock 18 Heat Cool 17 Nor...

Reviews: