L3722C 7−DAY PROGRAMMABLE THERMOSTAT

HEAT − Using the Heat Mode

Enabling and Disabling Heat Mode

The thermostat must be in the heat mode to control the
heating equipment. Press the HEAT button to enable or
disable HEAT mode. If the thermostat is in cool or off
mode, pressing the HEAT button enables the heat mode
(indicated by HEAT in the lower right corner − see figure 4).

Heat

Prog

Fan

Settings

Cool

Day/Time

Hold

Enter

(DOOR
OPEN)

Auto

Copy

(Outside)

66

5:30

70

82

Figure 4. Turn Heat ON/OFF

If the thermostat is in heat mode, heat mode is disabled
when the HEAT button is pressed. This is indicated by OFF
near the right side of the display as shown in figure 5.

75

ROOM

°

75

HEAT SETPOINT

°

OFF

Figure 5. Heat/Cool Mode Disabled

Heating Demand

Set the thermostat to heat mode to control the heating
equipment. Then, if the room temperature is lower than the
temperature setpoint, as shown in figure 6, the thermostat
detects a heating demand and will activate the heating
equipment to satisfy the demand.

72

ROOM

°

75

HEAT SETPOINT

°

HEAT

Figure 6. Heating Demand

Heating operation is indicated by a flame icon in the lower
right corner. When the actual temperature rises above the
temperature setpoint, the flame icon will disappear. This
indicates that the heating demand has been satisfied and
that the heating equipment has been turned off.

If your system supports 2−stage heating (as does the
L3722C thermostat), you may notice various heating lev-
els being delivered during a demand.

NOTE − Heating equipment is activated for at least 3 min-
utes if no buttons are pressed during the demand interval.

COOL − Using the Cool Mode

Enabling and Disabling Cool Mode

Use the COOL button to enable or disable cool mode as
desired. If the thermostat is in heat or off mode, cool mode
is enabled when the COOL button is pressed. This is indi-
cated by COOL on the right side of the display (figure 8).

Heat

Prog

Fan

Settings

Cool

Day/Time

Hold

Enter

(DOOR
OPEN)

Auto

Copy

(Outside)

66

i0:30

75

70

Figure 7. Turn Cool ON/OFF

If the thermostat is in cool mode, pressing the COOL but-
ton  disables cool mode (indicated by OFF in the SYSTEM
box − see figure 5).

Cooling Demand

Set the thermostat to cool mode to control the cooling
equipment. Then, if the room temperature is higher than
the temperature setpoint, as shown in figure 7, the thermo-
stat detects a cooling demand and will activate the cooling
equipment to satisfy the demand.

Cooling operation is indicated by flashing snowflake"
icons on the right side of the display. When the actual tem-
perature drops below the temperature setpoint, the snow-
flake icons will disappear. This indicates that the cooling
demand has been satisfied and that the cooling equipment
has been turned off.

If your system supports 2−stage cooling (as does the
L3722C thermostat), you may notice various cooling levels
being delivered during a demand. Also, if a small cooling
demand is present, "Lo" will be displayed in the SYSTEM
box. However, if a large cooling demand is present, "Hi" will
be displayed in the lower right corner (shown in figure 8).

80

ROOM

°

Hi

Lo

FAN
AUTO

COOL

76

°

68

HEAT SETPOINT

°

COOL SETPOINT

Figure 8. Cooling Demand

Summary of Contents for ComfortSense L3722C

Page 1: ...rogram 6 FAN Controlling Fan Operation 5 Displaying Outside Temperature 6 SETTINGS Filter Maintenance Reminder 6 Service Indicator 6 Thermostat RESET 6 Removing Installing Thermostat 7 Default Thermostat Settings 7 Thermostat Output Table 7 Technical Specifications 7 General These instructions are intended as a general guide and do not supersede local codes in any way Consult authorities having ju...

Page 2: ...seconds or the HOME screen will re turn Heat Prog Fan Settings Cool Day Time Hold Enter DOOR OPEN Auto Copy Outside Figure 3 Thermostat Buttons When an Arrow HOLD HEAT or COOL button is pressed SETPOINT and the temperature setting appears for 15 seconds If desired start making changes within 15 sec onds or the HOME screen will return The backlight will turn off 15 seconds after the HOME screen rea...

Page 3: ...during a demand NOTE Heating equipment is activated for at least 3 min utes if no buttons are pressed during the demand interval COOL Using the Cool Mode Enabling and Disabling Cool Mode Use the COOL button to enable or disable cool mode as desired If the thermostat is in heat or off mode cool mode is enabled when the COOL button is pressed This is indi cated by COOL on the right side of the displ...

Page 4: ...oint is displayed to the right of the actual room temperature Each button press adjusts the setpoint up or down by 1 degree After the desired setpoint is reached the HOME screen will reappear after about 15 seconds Permanent Hold Mode At any time the program is running from the HOME screen set a permanent hold program override by press ing the HOLD button see figure 9 The thermostat now functions ...

Page 5: ...g to repeat the same program for other days A Press the PROG button then press the COPY button The display clears the screen except for Copy from MO with MO flashing Press the COPY button again to copy Monday s program B The display changes to Copy to MO Use the ar row buttons to scroll to the desired day where you want the same program as Monday Press the COPY button C Repeat steps A and B for as...

Page 6: ...onds after the final arrow button press OR press the ENTER button at any time to store any changes and exit to the HOME screen After either programmed interval has elapsed the remind er will be displayed as shown in figure 17 COOL OFF AUTO EMG HEAT I0 26 PROG A B C D HOLD FAN ON AUTO FILTER SERVICE MAINTENANCE 76 ROOM MO AM PM COOL OFF AUTO EMG HEAT FAN ON AUTO FILTER SERVICE MAINTENANCE 76 Servic...

Page 7: ... is above setpoint 0 5F but below setpoint 1 5F AND 30 minute upstage timer HAS NOT expired With a LARGE cool demand temperature is above setpoint 1 5F OR 30 minute upstage timer HAS expired Default Thermostat Settings Default thermostat settings are in table 3 and the default program is shown in table 4 Table 3 Default Thermostat Settings Mode Heat Perm Hold Heat Setpoint Perm Hold 70 F or 21 C C...

Page 8: ...me elapsed time between any furnace activation next furnace activation 6 minutes Minimum elapsed time between any compressor activa tion and the next compressor activation 6 minutes NOTE All protection timers except the compressor OFF timer can be over ridden if a heating or cooling demand is initiated or terminated using the UP DOWN HEAT or COOL buttons Equipment Protection Override Both the mini...