background image

INSTALLATION, USE, MAINTENANCE MANUAL

• 10 •

USING THE APPLIANCE

WORK LIMITS

CAUTION!

This appliance should only be used by adults. Make sure that children do not 
touch the controls or play with the appliance. This appliance has been designed 
for use as a heating and cooling appliance in rooms that are clean and frequen-
ted by persons (with normal pollution). Avoid using for any other purpose. This 
appliance should not be used in places with suspended dust/powder or in po-
tentially explosive atmospheres, in very damp environments or in the presence 
of oil in suspension or in particularly aggressive atmospheres.

The units have the following operating limits:
- it can’t be installed in areas with anomalous heat and humidity condi

-

tions;

- it can’t be installed outdoors;
- it can’t be installed in explosive environments;
- it can’t be installed in a corrosive atmosphere.

SUMMER (COOLING)

Minimum inlet water temperature

+4°C

Maximum operating pressure

8 bar

Maximum room air temperature

+35°C

Maximum room air humidity

80%

WINTER (HEATING)

Maximum inlet water temperature

+80°C

Maximum operating pressure

8 bar

Minimum room air temperature

+4°C

Maximum room air humidity

80%

Maximum room air temperature

+35°C

USING THE CONTROL PANEL

If  the  appliance  has  a  built-in  control  panel,  raise  the  flap  and  proceed  as         
follows.

Cooling mode

Put the season selector switch from the off position ( ) to the summer position 
( ).
The fan starts immediately.

Heating mode

Put the season selector switch from the off position ( )  to  the  winter  position        
( ). 
The fan starts.
In models with minimum temperature thermostat (optional), the fan starts when 
the internal heat exchanger is sufficiently hot. If the water is not hot enough, the 
fan does not start.

Selecting the fan speed

Put the selector switch to the required speed.
The higher the speed the quicker the room will be heated/cooled, although ap-
pliance operation will be noisier (Pic. 22).

The room temperature may be set approx. between 10°C and 30°C. If the 

appliance does not have a built-in control panel, but is controlled by a 
wall-mounted thermostat, refer to the thermostat instructions for use.

Automatic temperature adjustment

This control panel has a built-in temperature sensor, which measures the room 
air temperature. This information is used for the automatic control of the fan 
or introduction of water into the internal exchanger through the solenoid valve   
(optional).
The appliance this keeps the room at the temperature set by the user.

Pic. 21

Pic. 22

Pic. 22

Pic. 23

Min. speed

Turn the knob to select the desired temperature

Med. speed

Max speed

Off

Winter(heating)

Summer (cooling)

Summary of Contents for ALLEGRA II

Page 1: ...www lennoxemea com INSTALLATION USE MAINTENANCE MANUAL CENTRIFUGAL FAN COIL UNIT ALLEGRA II 0 6 6 7 kW 105 1500 m3 h ALLEGRA2 IOM 1803 E ...

Page 2: ......

Page 3: ...o the water mains 7 Condensate water drainage 8 ELECTRICAL CONNENCTION 8 CONNECTIONS TO THE TERMINAL BOARD 8 Without control panel 8 With control panel 8 CHANGING THE MOTOR SPEED OF ROTATION 9 TESTING THE FANCOIL 9 TURNING THE COIL 9 WORK LIMITS 10 USING THE APPLIANCE 10 Using the control panel 10 CLEANING AND MAINTENANCE 11 Ordinary maintenance 11 Cleaning the air filter 11 Cleaning the housing a...

Page 4: ...om the electricity supply Do not open the flaps giving access to the internal parts of the appliance wi thout having first put the system on off switch to off Do not introduce sharp pointed objects through the air intake and outlet grilles Do not leave packing material cardboard staples plastic bags etc within reach of children since they could be a source of danger Dispose of correctly Do not sit...

Page 5: ...oils numbers n 1 1 1 1 1 1 1 1 1 1 Coil used for cooling and heating Rows number n 4 4 4 4 4 4 4 4 4 4 Water content litri 0 7 1 1 1 6 2 0 2 4 2 8 3 2 3 2 3 7 4 1 Hydraulic connection Ø Gas female Ø 1 2 1 2 1 2 3 4 3 4 3 4 3 4 3 4 3 4 3 4 General features Unit lenght with cabinet L mm 600 750 900 1050 1200 1350 1500 1500 1650 1800 Unit lenght without cabinet M mm 380 530 680 830 980 1130 1280 1280...

Page 6: ...Before installing the appliance remove the housing if present Raise the flaps covering the control panel and the water connections Remove the two screws fixing the housing to the fan coil load bearing structure Gipping the rear of the housing remove it as shown in the Pic 5 NOTE be careful of the lugs on the front part of the load bearing structure as shown in Pic 10 Put the cabinet in the packing...

Page 7: ...NNECTIONS CONNECTION TO THE WATER MAINS CAUTION Always use a wrench and nose key for connection of the coil to the pipes Pic 12 If the solenoid valve is installed suitably insulate the valve body with insulating material Pic 13 Connect the water inlet and outlet pipes observing the indications given on the side of the appliance Correctly insulate the water supply pipes to prevent drip ping during ...

Page 8: ...earth wire to the relative terminal marked with the symbol Check the earth connection Comply with the safety regulations in force in the country of installation WITHOUT CONTROL PANEL The electrical connections should be made to the terminal board on the side of the appliance Each terminal is identified by the label to be found on the terminal board WITH CONTROL PANEL The electrical connections sho...

Page 9: ...ore switching on the appliance Before mounting the housing if present fill the system bring it up to pres sure and bleed Make the water circulate and check for leaks Check correct operation of the fan coil at the 3 speeds of the solenoid valves and of the minimum temperature thermostat if installed Pic 18 Rosso Blu Nero Motore Motore Comune A 180 1 2 3 4 5 6 7 E Take out auxiliary coil C if presen...

Page 10: ...ING THE CONTROL PANEL If the appliance has a built in control panel raise the flap and proceed as follows Cooling mode Put the season selector switch from the off position to the summer position The fan starts immediately Heating mode Put the season selector switch from the off position to the winter position The fan starts In models with minimum temperature thermostat optional the fan starts when...

Page 11: ...c 24 Pic 25 WATER DETERGENT WATER DETERGENT CLEANING THE HOUSING AND THE CONTROL PANEL To clean the housing use a dry soft cloth to avoid scratching the enamel To clean the control panel and the air outlet louvres use a vacuum cleaner fitted with a soft dusting tool or use a separate brush Delicately clean the louvres and the controls by removing dust from the cracks and corners Under no circumsta...

Page 12: ...re disman tling the appliance is to disconnect it totally from the electricity supply This appliance has been made using recyclable materials copper aluminium brass plastic assembled by screws and push fits to make separation of the parts easy Contact a firm specialised in differentiated waste disposal it is the only way to be certain of correct recycling and thereby contribute to protection of th...

Page 13: ......

Page 14: ...curring liability Improper installation adjustment alteration service or maintenance can cause property damage or personal injury Installation and service must be performed by a qualified installer and servicing agency ALLEGRA2 IOM 1803 E SALES OFFICES BELGIUM AND LUXEMBOURG POLAND 32 3 633 3045 48 22 58 48 610 FRANCE PORTUGAL 33 1 64 76 23 23 351 229 066 050 GERMANY SPAIN 49 0 211 950 79 60 34 91...