Page 2
SPECIFICATIONS
Gas
Heating
Performance
Model No. ML193UH030XE36B ML193UH045XE36B ML193UH070XE36B ML193UH090XE36C
AHRI Reference No.
20256877
20256878
20256879
20256880
1
AFUE
93%
93%
93%
93%
Input - Btuh
30,000
44,000
66,000
88,000
Output - Btuh
29,000
42,000
63,000
84,000
Temperature rise range - °F
25 - 55
30 - 60
40 - 70
50 - 80
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10
3.5 / 10.0
3.5 / 10.0
3.5 / 10
High static - in. w.g.
0.5
0.5
0.5
0.5
Connections
in.
Intake / Exhaust Pipe (PVC)
2 / 2
2 / 2
2 / 2
2 / 2
Gas pipe size IPS
1/2
1/2
1/2
1/2
Condensate Drain Trap (PVC pipe) - i.d.
3/4
3/4
3/4
3/4
with furnished 90° street elbow
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 Mipt
with field supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT
3/4 slip x 3/4 MPT
3/4 slip x 3/4 MPT
3/4 slip x 3/4 MPT
Indoor
Blower
Wheel nom. dia. x width - in.
10 x 8
10 x 8
10 x 8
10 x 8
Motor Type
DC Brushless
DC Brushless
DC Brushless
DC Brushless
Motor output - hp
1/2
1/2
1/2
1/2
Tons of add-on cooling
1.5 - 3
1.5 - 3
1.5 - 3
1.5 - 3
Air Volume Range - cfm
175 - 1435
355 - 1420
355 - 1430
405 - 1410
Electrical
Data
Voltage
120 volts - 60 hertz - 1 phase
Blower motor full load amps
6.8
6.8
6.8
6.8
Maximum overcurrent protection
15
15
15
15
Shipping Data
lbs. - 1 package
120
120
127
144
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.
SPECIFICATIONS
Gas
Heating
Performance
Model No.
ML193UH090XE48C
ML193UH110XE48C
ML193UH110XE60C
AHRI Reference No.
20256881
20256882
20256883
1
AFUE
93%
93%
93%
Input - Btuh
88,000
110,000
110,000
Output - Btuh
84,000
104,000
105,000
Temperature rise range - °F
45 - 75
50 - 80
45 - 75
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0
3.5 / 10
3.5 / 10
High static - in. w.g.
0.5
0.5
0.5
Connections
in.
Intake / Exhaust Pipe (PVC)
2 / 2
2 / 2
2 / 2
Gas pipe size IPS
1/2
1/2
1/2
Condensate Drain Trap (PVC pipe) - i.d.
3/4
3/4
3/4
with furnished 90° street elbow
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 Mipt
3/4 slip x 3/4 Mipt
with field supplied (PVC coupling) - o.d.
3/4 slip x 3/4 MPT
3/4 slip x 3/4 MPT
3/4 slip x 3/4 MPT
Indoor
Blower
Wheel nom. dia. x width - in.
10 x 10
10 x 10
11-1/2 x 10
Motor Type
DC Brushless
DC Brushless
DC Brushless
Motor output - hp
3/4
3/4
1
Tons of add-on cooling
2.5 - 4
2.5 - 4
3 - 5
Air Volume Range - cfm
830 - 1710
850 - 1750
1085 - 2150
Electrical
Data
Voltage
120 volts - 60 hertz - 1 phase
Blower motor full load amps
8.4
8.4
10.9
Maximum overcurrent protection
15
15
15
Shipping Data
lbs. - 1 package
144
156
158
NOTE - Filters and provisions for mounting are not furnished and must be field provided.
1
Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.