Lennox 15CHAX?24 Installation Instructions Manual Download Page 3

Page 3

Parts Arrangement

General

These installation instructions are intended as a general
guide only, for use by an experienced, licensed contractor
(or equivalent).

The 15CHAX units are single−package electric units
designed for outdoor installation on a rooftop or a slab. The
units are equipped with a transformer and blower control
for applications which do not include electric heat. Electric
heat sections are available for separate order.

The unit must be sized based on heat loss and heat gain
calculations made according to the methods of the Air
Conditioning Contractors of America (ACCA).

The units are shipped assembled. All piping, refrigerant
charge, and electrical wiring are factory−installed and
tested. The units require electric power, condensate drain
and duct connections at the point of installation.

Use of this unit as a construction heater or air conditioner is
not recommended during any phase of construction. Very
low return air temperatures, harmful vapors and operation
of the unit with clogged or misplaced filters will damage the
unit.

If this unit has been used for heating or cooling of buildings
or structures under construction, the following conditions
must be met or the warranty will be void:

 

A room thermostat must control the unit. The use of
fixed jumpers that will provide continuous heating or
cooling is not allowed.

 

A pre−filter must be installed at the entry to the return air
duct.

 

The return air duct must be provided and sealed to the
unit.

 

Return air temperature range between 55°F (13°C)
and 80°F (27°C) must be maintained.

 

Air filters must be replaced and pre−filter must be re-
moved upon construction completion.

 

The unit components, duct system, air filters and evap-
orator coil must be thoroughly cleaned following final
construction clean−up.

 

The unit operating conditions (including airflow, cool-
ing operation, and heating operation) must be verified
according to these installation instructions.

Requirements

These units must be installed in accordance with all
applicable national and local safety codes.

These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
having jurisdiction before installation.

If components are to be added to a unit to meet local codes,
they are to be installed at the dealer’s and/or customer’s
expense.

These units are design listed by UL in both the United
States and Canada as follows:

  

   For use as a cooling unit.

  

  For outdoor installation only.

Summary of Contents for 15CHAX?24

Page 1: ...it If you find any damage im mediately contact the last carrier WARNING Improper installation adjustment alteration service or maintenance can cause property damage person al injury or loss of life In...

Page 2: ...HAX 24 75 94 117 94 16 29 15CHAX 30 75 94 117 94 16 29 15CHAX 36 83 97 121 104 16 30 15XHAX 42 110 138 163 129 21 33 15CHAX 48 114 139 164 134 21 33 5 15CHAX 60 119 145 171 140 21 33 5 Model No A B C...

Page 3: ...s under construction the following conditions must be met or the warranty will be void A room thermostat must control the unit The use of fixed jumpers that will provide continuous heating or cooling...

Page 4: ...of the unit Rigging Setting Unit Exercise care when moving the unit Do not remove any packaging until the unit is near the place of installation An optional lifting lug kit 92M51 may be purchased sep...

Page 5: ...hat each appliance connected to the common venting system is venting properly step 3 return all doors windows exhaust fans fireplace dampers and any other gas burning appliances to their previous mode...

Page 6: ...e job They should NOT be sized by simply matching the dimensions of the duct connections on the unit Ducting installed outdoors MUST be insulated and waterproofed CAUTION When fastening duct system to...

Page 7: ...ower supplies Failure to disconnect all power supplies could result in personal injury or death CAUTION When connecting electrical power and control wir ing to the unit waterproof type connectors MUST...

Page 8: ...Page 8 Figure 7 15CHAX Series Packaged Electric Units Typical Wiring Diagram...

Page 9: ...jumper positions gently pull the jumper off the pins and place it on the desired set of pins The following section outlines the different jumper selections available and conditions associated with ea...

Page 10: ...rformance 0 through 0 80 in w g 0 through 200 Pa External Static Pressure Range AD Jumper Speed Positions AD JUST COOL Speed HEAT Speed CONTINOUS FAN Speed JUST Jumper A B C D A B C D A B C D Jumper S...

Page 11: ...devices LSOM LED Functions Power LED green Voltage within the range of 19 28VAC is present at the system monitor power connec tion Alert LED yellow Communicates an abnormal system condition through a...

Page 12: ...ondenser fan is not running 4 Return air duct has substantial leakage 5 If low pressure switch is present see Flash Code 1 info Yellow Alert Flash Code 3 Short Cycling Compres sor is running only brie...

Page 13: ...l stop System Performance For maximum performance of this cooling system the operating temperatures and pressure should be checked and subcooling determined at Standard ARI test conditions of 82 F out...

Page 14: ...y lubricated and require no further lubrication Motors should be cleaned yearly to prevent the accumulation of dust and dirt on the windings or motor exterior Coil Dirt and debris should not be allowe...

Reviews: