Unit Dimensions − inches (mm)

CORNER WEIGHTS  lbs. (kg)

Model

AA

BB

CC

DD

Model

Number

lbs.

kg

lbs.

kg

lbs.

kg

lbs.

kg

12CHP024

77

35

56

25

61

28

82

37

12CHP030

86

39

63

29

69

31

92

42

12CHP036

117

53

85

39

93

42

125

57

12CHP042

118

54

86

39

94

43

126

57

12CHP048

121

55

88

40

96

44

129

59

12CHP060

127

57

92

42

101

46

135

61

CENTER OF GRAVITY  inches (mm)

Model

EE

FF

Model

Number

inch

mm

inch

mm

12CHP024

217/8

556

261/2

673

12CHP030

217/8

556

261/2

673

12CHP036

233/4

603

311/4

794

12CHP042

233/4

603

311/4

794

12CHP048

233/4

603

311/4

794

12CHP060

23−3/4

603

31−1/4

794

OUTDOOR COIL

EXHAUST AIR

FRONT VIEW

TOP VIEW

TOP VIEW BASE SECTION

BACK VIEW

LEFT SIDE

OUTDOOR

COIL

INTAKE

AIR

CONDENSATE

DRAIN

COMPRESSOR

DOWNFLOW

SUPPLY AIR

OPENING

OUTDOOR

COIL FAN

DOWNFLOW

RETURN AIR

OPENING

HORIZONTAL

SUPPLY AIR

OPENING

HORIZONTAL

RETURN AIR

OPENING

AA

D

BB

CC

DD

CONDENSER COIL

INTAKE AIR

OUTDOOR

COIL

OUTDOOR COIL

EXHAUST AIR

A

C

B

B

RIGHT SIDE

BLOWER

C

HORIZONTAL

RETURN AIR

OPENING

(048/060)

A

L

E

F

G

G

2 (51)

FF

EE

FILTER

RACK

BASE RAIL

27/16

(62)

45/8
(117)

CENTER

OF

GRAVITY

K

K

K

K

J

J

J

J

E

H

N

FORKLIFT

SLOTS

(Front and

Back Only)

BASE RAIL

BASE RAIL

P

M

BASE RAIL

BASE RAIL

INDOOR

COIL

BLOWER

 

 

 

OPTIONAL

ELECTRIC

HEAT

(Field

Installed)

ELECTRICAL

INLETS

OPTIONAL

ELECTRIC HEAT

(Field Installed)

ELECTRIC

HEAT

POWER INLET

REFRIGERANT

SERVICE

PORTS

Model

A

B

C

D

E

F

G

Model

Number

inch

mm

inch

mm

inch

mm

inch

mm

inch

mm

inch

mm

inch

mm

−024

2711/16

703

455/8

1159

455/8

1159

251/4

641

113/16

46

4

102

17/8

48

−030

3111/16

805

455/8

1159

455/8

1159

291/4

743

113/16

46

4

102

17/8

48

−036, −042, −048, −060

3311/16

856

5411/16

1389

495/8

1260

317/16

799

11/8

29

61/4

159

21/4

57

Model

H

J

K

L

M

N

P

Model

Number

inch

mm

inch

mm

inch

mm

inch

mm

inch

mm

inch

mm

inch

mm

−024

155/8

397

111/2

292

171/2

445

4

102

5

127

463/8

1179

463/8

1179

−030

155/8

397

111/2

292

171/2

445

4

102

5

127

463/8

1179

463/8

1179

−036, −042, −048, −060

171/8

435

12

305

211/2

546

55/8

143

41/8

105

551/4

1403

501/2

1283

Summary of Contents for 12CHP024

Page 1: ...GED HEAT PUMP UNIT 2 5 TONS 504 176M 06 03 Supersedes 01 00 Table of Contents Shipping Packing List 1 General 1 Unit Dimensions 2 Parts Arrangement 3 Requirements 3 Clearances 4 Rigging Setting Unit 4...

Page 2: ...UTDOOR COIL EXHAUST AIR A C B B RIGHT SIDE BLOWER C HORIZONTAL RETURN AIR OPENING 048 060 A L E F G G 2 51 FF EE FILTER RACK BASE RAIL 2 7 16 62 4 5 8 117 CENTER OF GRAVITY K K K K J J J J E H N FORKL...

Page 3: ...gent to remove any residue from manufacturing processes Limitations for unit and appropriate accessories must also be observed The unit must not be installed with any duct system in the outdoor air st...

Page 4: ...to prevent ice accumulation Unit should not be located near walkways to prevent possible icing of surface from defrost condensate Avoid placing unit near quiet areas i e sleeping quarters or study ro...

Page 5: ...e control assembly 8 Field wiring of auxiliary heater is separate from unit power supply Wire power supply wiring for the heater to appropriate connections on heater kit OPTIONAL ELECTRIC HEAT INSTALL...

Page 6: ...Page 6 12CHP Series Heat Pump Packaged Units Typical Wiring Diagram Does not Include 12CHP060 FIGURE 7...

Page 7: ...Page 7 12CHP060 Series Heat Pump Packaged Units Typical Wiring Diagram FIGURE 8...

Page 8: ...table could serve as a use ful service guide Table 3 should be used when unit is charged during the heating mode If outdoor ambient is below 45 F run unit through defrost cycle first wait 15 minutes...

Page 9: ...outdoor fan The reversing valve is not energized in the heating mode The thermostat again automatically brings on the in door blower at the same time Upon satisfying heating de mand the thermostat op...

Page 10: ...ally consists of changing or cleaning filters and under some conditions cleaning the coils WARNING Electric shock hazard Can cause inju ry or death Before attempting to per form any service or mainten...

Reviews: