FEATURES - ICOMFORT WI-FI® FLEX THERMOSTAT
INSTALLER SETTINGS
Air Handler
•
Equipment Name (Keyboard tool)
•
Electric Heating Airflow
•
High Cooling Airflow
•
High HP Airflow
•
Continuous Indoor Blower Airflow (
450 to 1150 cfm,
default is
600 cfm
)
•
Humidification Airflow (Humidifier)
•
Dehumidification Airflow (Dehumidifier)
(60 to 80%, default is 70%)
Dehumidification Airflow is 60 to 80% reduction of the
High Cooling Airflow parameter.
•
Delay Settings
•
Heating Indoor Blower OFF
(
0 to 10 sec., default is
10 sec.
)
•
Heating Indoor Blower ON
(
0 to 5 sec., default is
0 sec.
)
• Cooling Indoor Blower OFF
(
0 to 30 sec., default is
0 sec.
)
• Cooling Indoor Blower ON
(
0 to 10 sec., default is
2 sec.
)
•
HP Indoor Blower OFF
(
0 to 60 sec., default is
45 sec.
)
•
HP Indoor Blower ON
(
0 to 30 sec., default is
0 sec.
)
Thermostat
• Equipment Name
•
Temp. Reading Calibration (
-5 to 5°F, default is
0°F
)
•
Humidity Reading Calibration (
-10 to 10°F, default is
0°F
)
ADJUST SYSTEM DEVICES SCREEN (Continued)
Furnace
•
Equipment Name (Keyboard tool)
•
Continuous Indoor Blower Airflow (
250 to 1150 cfm,
default is
315 cfm
)
•
Dehumidification Airflow % (
60 to 80%, default is
70%
)
•
Delay Settings
•
Heating Indoor Blower OFF
(
60 to 180 sec., default is dependent on DIP switch
setting in furnace
)
•
Heating Indoor Blower ON
(
15 to 45 sec., default is
30 sec.
)
• Cooling Indoor Blower OFF
(
0 to 30 sec., default is
0 sec.
)
• Cooling Indoor Blower ON
(
0 to 10 sec., default is
2 sec.
)
•
HP Indoor Blower OFF
(
0 to 60 sec., default is
45 sec.
)
•
HP Indoor Blower ON
(
0 to 30 sec., default is
0 sec.
)
HP
Dual Fuel
•
Heating Airflow Control Type - Selections available if
Discharge Air Temperature Sensor is installed (
Fixed
cfm, fixed Discharge Air Temperature
)
With Discharge Air Temperature:
•
Low Heating Discharge Air Temperature - Available
if Discharge Air Temperature Sensor is installed
(
110 to 140°F, default is
125°F
)
•
High Heating Discharge Air Temperature - Available
if Discharge Air Temperature Sensor is installed
(
120 to 150°F, default is
135°F
)
With Fixed cfm:
•
Low Heating Airflow
(
325 to 475 cfm, default is
475 cfm
)
•
High Heating Airflow
(
800 to 1100 cfm, default is
975 cfm
)
•
High Cooling Airflow
(
270 to 1150 cfm, default is
825 cfm
)
•
High HP Airflow (
300 to 1400 cfm, default is
800 cfm
)
All furnace default airflow settings are dependent on
furnace capacity.
NOTE - Humidification and Dehumidification Airflow
settings are only viewable if those products are added
during setup.