NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SAFETY / LISTING LABEL  - FRENCH

SAFETY / LISTING LABEL  - ENGLISH

IGN #11-0316

DATE OF MANUFACTURE / DATE DE FABRICATION

2011

2013

2014

2012

JAN

FEB MAR

APR MAY

JUN

JUL

AUG SEP

OCT

NOV DEC

CAUTION:

  HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP 

CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY. 

KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING INSTRUCTIONS 

ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY. DO NOT 

OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S) 

SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE 

INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS 

APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE 

AGENCY OR GAS SUPPLIER.

 

MODEL

                   

RAVELLE™ 42

MANUFACTURED BY:

LENNOX HEARTH PRODUCTS

PO BOX 987

AUBURN, WA., USA 98071

 RAVL42

SERIAL

 NO.

Report No.

050-S-08c-5

LISTED VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL

TESTED TO ANSI Z21.88-2005/CSA 2.33-2005 “VENTED GAS FIREPLACE HEATERS”, UL307b, CSA P.4.1-02, AND CGA 2.17-M91.

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY.  IF NOT, FOLLOW THE CURRENT ANSI Z223.1/

NFPA  54-LATEST  EDITION  (USA)  OR  CAN/CGA    B149.1-LATEST  EDITION  (CANADA).  THIS  APPLIANCE  MUST  BE  INSTALLED  IN 

ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES 

ONLY - MASONRY OR FACTORY BUILT.  THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS. 

THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN 

AFTERMARKET,  PERMANENTLY  LOCATED,  MANUFACTURED  (MOBILE)  HOME  WHERE  NOT  PROHIBITED  BY  LOCAL  CODES.  SEE 

OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS 

USED.  MAY BE INSTALLED IN RESIDENTIAL BEDROOMS.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, 

FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST EDITION (CANADA).

DO NOT REMOVE OR COVER THIS LABEL

FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.

MINIMUM CLEARANCES TO COMBUSTIBLES IN INCHES

Front corners to enclosure (from stand-offs) 

Hearth Extension - not required but recommended

Back to enclosure (from stand-offs) 

Rear corners to enclosure (from stand-offs) 

0

Top to header (from stand-offs) 

Base of unit to mantel 

47-5/8

Bottom of unit to floor 

Base of unit to top trim/facing 

41-5/8

Side trim or wall to edge of door glass 

7.5

See owner’s manual for additional clearance information on mantels and direct vent pipe.

 

NG 

LP 

 

NG 

LP

Input Rate on “HI” (BTU/H)  

42,000 

36,000 

Minimum Inlet Pressure (in. WC)  

11

Input Rate on “LO” (BTU/H) 

29,500 

25,000 

Manifold Pressure on “HI” (in. WC)  

3.5 

10

Orifice Size (DMS)  

#30 

#49 

Manifold Pressure on “LO” (in. WC)  

1.7 

5.1

Blower Electrical Rating: 120 VAC, 60 Hz, Less Than 2 Amps
*Unit factory equipped for 0-2000 ft/0-610 m, in Canada 0-4500 ft/0-1370 M.  For altitudes above 2,000 ft/610m (in Canada 4500 

ft/1370m) de-rate the appliance by four (4)% for every 1,000 ft (405 m). 
See owner’s manual for instructions on changing cassette/valve assembly.

US

Portland

Part No. 36280  Rev. NC, 01/2011

HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU GAZ - INSERTION DE FOYER AU GAZ - NE PAS UTILISER 

AVEC DU COMBUSTIBLE SOLIDE

TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», UL307B, CSA P.4.1-02, ET CGA 2.17-M91.

CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI 

NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA). CET APPAREIL DOIT ÊTRE INSTALLÉ 

SELON LES DIRECTIVES D’INSTALLATION DU FABRICANT. POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE SOLIDE 

SEULEMENT - DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE. CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS CONÇU POUR ÊTRE 

UTILISÉ AVEC DES FILTRES À AIR. CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE 

ET PEUT ÊTRE INSTALLÉ DANS UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE 

PERMETTENT. VOIR LE MANUEL D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE 

AVEC D’AUTRES TYPES DE GAZ À MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.
DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.

SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE CONFORMES 

AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.

DANGER:

 CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES 

ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS LA PIÈCE. 

GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES 

INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT TEMPS. VOIR LES MANUELS 

D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. SEUL LE PANNEAU VITRÉ FOURNI PAR LE MANUFACTURIER 

PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. EN AUCUN CAS, L’APPAREIL NE PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE 

BRISÉE. LE REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
AVERTISSEMENT: UNE INSTALLATION INADÉQUATE DE MÊME QU’UN AJUSTEMENT, UNE MODIFICATION, UNE RÉPARATION OU UN 

ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. RÉFÉREZ-VOUS AU MANUEL 

D’ENTRETIEN LIVRÉ AVEC CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE 

DE SERVICE OU UN FOURNISSEUR DE GAZ.

IGN #11-0316

N’ENLEVEZ PAS OU NE COUVREZ PAS CETTE ÉTIQUETTE

SPÉCIFICATIONS

 

NG 

LP 

 

NG 

LP

Entrée Max/min BTU/hr 0-4500 Pi (0-1370 M)*  42,000  36,000  Pression Minimum D’entrée Du Gaz

 (IN. WC/C.E.)  5 

11

Entrée Minimum BTU/hr 0-4500 Pi (0-1370 M)*  29,500  25,000  Pression À La Sortie - HI  (IN. WC/C.E.) 

3.5 

10

Orifice (DMS)* 

#30 

#49 

Pression À La Sortie - LO (IN. WC/C.E.) 

1.7 

5.1

Spécifications Électrique 120 Vca, 60 Hz, Moins De 2 Ampères
*En altitude, au-delà de 2000 pi/610 m, (au canada 0-4500 pi/0-1370m) la capacité énergétique de l’appareil diminue de quatre (4)% pour chaque 
1000 pi (405 m).
Référez-vous au manuel d'instructions du propriétaire pour changer le bloc d'assemblage de la valve.

DÉGAGEMENTS AUX COMBUSTIBLES - EN POUCES (MILLIMÈTRES)

Coins avant au caisson (depuis les espaceurs)  0 (0mm)  Extension d’âtre - Prolongement de l'âtre - Non requis mais recommandé
Du dos au caisson (depuis les espaceurs) 

0 (0mm)  Côtés arrière au caisson (depuis les espaceurs) - 0 (0mm)

Du dessus au support (depuis les espaceurs)  0 (0mm)  De la base de l’unité au manteau - 47-5/8"" (1210mm)
Du fond de l’unité au plancher 

0 (0mm)  De la base de l’unité à la finition/ façade du dessus - 41-5/8" (1057mm)

De la finition du côté ou du mur au bord de la vitre   7-1/2 (191mm) 
Voir le manuel d’installation pour plus d’informations sur les dégagements requis au manteau, conduits direct-vent et prolongement de 

l’’âtre.

 

MODÈLE

                      RAVELLE™ 42

FABRIQUÉ PAR:

LENNOX HEARTH PRODUCTS

PO BOX 987

AUBURN, WA., USA 98071

SERIAL

 NO.

Número de Rapport

050-S-08c-5

CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT CETTE 

ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.

US

Portland

Le numéro de série est indiqué dans la 

section anglophone de cette étiquette

La date de fabrication est indiquée dans la section anglophone de cette étiquette

 No. pièce #36280  Rev. NC, 01/2011

Summary of Contents for RAVELLE 42

Page 1: ...mmediately call your gas supplier from a neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department Installation and service must be perfo...

Page 2: ...13 Hearth Extension Considerations 13 Facing Installation Considerations 14 Face Installation 16 Vent Installation Application 17 Vent Parts List 17 Vent Considerations 19 Horizontal Vent Installation...

Page 3: ...s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con el vidrio y prevenir las q...

Page 4: ...la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette mesu...

Page 5: ...rruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la ch...

Page 6: ...ge to this appliance and or its operating controls is dangerous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning...

Page 7: ...be replaced prior to operating the appliance Goldandnickelplatedsurfacesmustbe cleaned with glass cleaner and a clean soft cloth before firing the first time or fingerprints will remain permanently N...

Page 8: ...D APPROVALS Must conform with all local state and national installation codes In the absence of local codes the installation must conform with National Fuel Gas Code ANSI Z223 1 latest edition also kn...

Page 9: ...l It is also important to note the thickness of the wall Before cutting the vent hole through the wall make sure ALL vent and termination clearances will be met see Pages 21 and 23 Electrical The stan...

Page 10: ...0mm Mantel The drawing at the lower right shows the minimum distances from the base of the fireplace to combustible mantel and facing material Combustible materials may be placed above and within the...

Page 11: ...to the valve wThe electrical power supply wiring should be routed to the right rear of the unit Note The fireplace may be placed directly on wood or non combustible flooring but NOT on vinyl floor co...

Page 12: ...20 3 4 527 47 3 4 1213 35 1 2 902 2 51 34 864 41 1041 38 1 4 972 30 762 43 1092 30 762 3 1 2 89 9 1 2 241 10 3 4 273 72 1 2 1842 6 7 8 175 18 3 16 462 32 5 16 821 3 1 2 89 5 127 6 1 4 159 2 1 4 57 GAS...

Page 13: ...fireplace must be raised the thickness of that hearth extension less the 7 8 22 mm For example if a 2 7 8 73 mm thick cultured stone is to be placed on the floor to serve as the hearth extension then...

Page 14: ...ce face see below Facing Installation Considerations Non combustible cement board such as Wonderboard Durock or Har dybacker must extend 10 254 mm above the 1 25 mm top reveal and a minimum of 3 76 mm...

Page 15: ...must be placed around the face A template Arch 75098 Foundry 75035 and Classic Louver 75101 should be used while installing the facing material Templates for the various faces may be purchased from y...

Page 16: ...e place face The acid wash will tarnish the face Consult your masonry installer Face Installation A number of different faces are available for the Ravelle 42 gas fire place however all the faces are...

Page 17: ...ventcomponentpartnotapprovedormanufactured by the approved vent manufacturer Installation other than as instructed by Lennox Hearth Products and the vent manufacturer s instructions Vent Parts List Se...

Page 18: ...h Wind 1250 Vinyl Siding Standoff Vent Parts List Vertical Direct vent pipe by Security Chimneys or Dura Vent may be used with the Ravelle 42 gas fireplace Please see the lists below to verify the com...

Page 19: ...le from the outside on the pipe or fittings They may be located by examining the inside of the female ends Supports Horizontal runs of vent must be supported every three feet Wall straps are available...

Page 20: ...ent termination on an exterior wall must meet all local and national building codes and must not be blocked or obstructed For allowable external vent terminations locations see the diagram on Page 23...

Page 21: ...and 23 the burner flame appearance should be evaluated to determined if the flue restrictors need to be set to a different position to adjust for variables in your installation Light the appliance an...

Page 22: ...hown below Use the restrictor positions indicated If the fireplace is vented with an elbow directly off the top of the flue collar and three to four feet of horizontal pipe is used then no restrictor...

Page 23: ...above meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to ser...

Page 24: ...r natural gas use only For LP conversions remove the air shield 5 Place Logs 3 4 and 5 on tab inserts Important Maintain a 1 4 6 4mm air space along the entire length of log Glowing Embers rockwool In...

Page 25: ...replace must be turned off at the electrical panel before any connections are made The loop of wire with the label attached E in Figure 29 may be cut and the wire leads from the wall mounted speed con...

Page 26: ...essure with the fireplace burning insert a small flat bladed screwdriver into the tap and turn a half turn counterclockwise Cover the tap with the line from a manometer and read the pressure Closethet...

Page 27: ...rminated with a grill When the fireplace is burning with or without the fireplace blower running air is drawn from a distant room lowering the pressure in that room through the return air duct into th...

Page 28: ...n Sheet Metal Screws One Wire Clamp The Forced Air Duct System allows you to direct warm air from your Ravelle 42 DV fireplace using a 150 CFM blower through six inch ducts into other rooms in the hou...

Page 29: ...additional piece of flooring F below should also be cut out for the blower box to slide through Save this piece F and nail it back in place after the blower box is installed 3 Slide the blower box thr...

Page 30: ...each joint 5 Secure the ducting to prevent sagging Wiring of the Forced Air Duct System Disconnect the electrical supply to the fireplace at the electrical panel prior to wiring the forced air system...

Page 31: ...nobs come with the kit Select the cover desired and fasten the speed control and cover to the box with the screws supplied Push the desired knob onto the shaft of the speed control 4 Remove the four s...

Page 32: ...le fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer la poussi re et les traces de...

Page 33: ...or attempted repair may result in a fire or explosion D DO NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to repla...

Page 34: ...and a hazardous situation See Figure 45 showing proper flame appearance When testing for proper operation If an optional thermostat is installed adjust it to its highest temperature setting Visually...

Page 35: ...h a 200 CFM blower with a variable speed control and an automatic temperature activated on off snap switch Operation 1 After the fireplace warms up a heat activated switch will turn on the blower A bl...

Page 36: ...Be sure to set the rocker switch to the OFF position when using the thermostat or remote control and set the thermostat or remote control to the lowest temperature when you wish to use the rocker swit...

Page 37: ...ot air outlet vents for lint or other accumulations Never block or restrict vent openings obstruct flow of ventilation air or use vents other than those approved for use with this appliance o Check th...

Page 38: ...led cover through which the valve control knobs protrude by removing the two allen head screws securing it and slide it off the valve knobs 6 Mark and disconnect wires on valve terminals 1 and 3 conne...

Page 39: ...atch light pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electro...

Page 40: ...f form 775241M 75064 RAVL42 CK NG to LP Conversion Kit NG to LP ref form 775250M Misc 75259 NP RAVL30 42 Nail Plates 4 x 12 galvanized 75247 Reducer 8 6 5 8 Reducer 8 to 6 5 8 75134 RAVL42 DUCTKT Forc...

Page 41: ...ushed Nickel 75317 AI42 TUSCAN BKNKL TUSCAN Black Nickel Screen Kit ref form 775289M 75029 Screen Face double Door black 43 1 4 W x 31 7 8 H INSETS Required Includes 1 Top and 1 Bottom Inset ref form...

Page 42: ...ET CGA 2 17 M91 CET APPAREIL DOIT TRE INSTALL CONFORM MENT AUX EXIGENCES DES CODES R GIONAUX ET DU CODE D INSTALLATION ANSI NFPA 54 DERNI RE DITION ETATS UNIS OU CAN CGA B149 1 DERNI RE DITION CANADA...

Page 43: ...nob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 9 If knob does not pop up when released stop and immediately call your service technician or gas supplier LIGH...

Page 44: ...cien qualifi ou le fournisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technicien qualifi ou le fourni...

Page 45: ...NOTES 45...

Page 46: ...d the following important information aboutyourappliance PleasecontactyourLennoxHearthProductsdealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please c...

Reviews: