18

Vent Parts List - Horizontal

Direct vent pipe by Security Chimneys™ or Dura-Vent

®

 may be used 

with the Ravelle™ 42 gas fireplace . Please see the lists below to verify 
the components available from each direct-vent pipe manufacturer . All 
horizontally terminated venting of the Ravelle 42 gas fireplace uses 8” 
x 5” size vent pipe and all vertically terminated venting uses 6-5/8” x 4” 
size vent pipe . The flue collar on the fireplace is 8” x 5” in size . Therefore, 
when vertically terminating it is necessary to use a reducer - part number 
75247 (available from Lennox Hearth Products) - to make the transition 
from the 8” x 5” flue collar to the 6-5/8” x 4” pipe . Snorkel terminations 
are available for applications which may require vertical rise on the building 
exterior . The components listed below come in a galvanized finish . Most 
of the components are also available in a painted black finish . Add a “B” 
to the end of the part number when ordering if a black part is desired .

8" x 5" Secure Vent Pipe by Security Chimneys

 

Part Number 

Description

 

SV5L6 

6" Pipe Length

 

SV5L12 

12" Pipe Length

 

SV5L24 

24" Pipe Length 

 

SV5L36 

36" Pipe Length 

 

SV5L48 

48" Pipe Length 

 

SV5LA 

6" Pipe, Adjustable

 

SV5LA12 

12" Pipe, Adjustable

 

SV5E45 

45º Elbow

 

SV5E90 

90º Elbow

 

SV5RSM 

Wall Radiation Shield

 

SV5VS 

Vinyl Shield Protector

 

SV5BF 

Firestop

 

SV5CHC-1 

Horizontal Termination Cap

 

SV5STC14 

Snorkel Termination (14") Cap

 

SV5STC36 

Snorkel Termination (36") Cap

 

SV5BM 

Wall Band

8" x 5" GS Pipe by Dura-Vent

 

Part Number    Description

 

1208 

6" Pipe Length

 

1207 

9"  Pipe Length

 

1206 

12" Pipe Length

 

1204 

24" Pipe Length

 

1203 

36" Pipe Length

 

1202 

8" Pipe Length

 

1211 

11" to 14-5/8" Pipe, Adjustable

 

1217 

17" to 24" Pipe, Adjustable

 

1290 

90° Elbow

 

1247 

Wall Thimble

 

1263 

Ceiling Firestop

 

1288 

Wall Strap

 

1281 

Snorkel Termination (36")

 

1282 

Snorkel Termination (14")

 

1284 

Horizontal Termination Cap

 

1285 

Horizontal Termination Cap (High Wind)

 

1250 

Vinyl Siding Standoff

Vent Parts List - Vertical

Direct vent pipe by Security Chimneys or Dura-Vent may be used with 
the  Ravelle  42  gas  fireplace .  Please  see  the  lists  below  to  verify  the 
components  available  from  each  direct-vent  pipe  manufacturer .  All 
horizontally terminated venting of the Ravelle 42 gas fireplace uses 8” 
x 5” size vent pipe and all vertically terminated venting uses 6-5/8” x 4” 
size vent pipe . The flue collar on the fireplace is 8” x 5” in size . Therefore, 
when vertically terminating it is necessary to use a reducer - part number 
75247 (available from Lennox Hearth Products) - to make the transition 
from the 8” x 5” flue collar to the 6-5/8” x 4” pipe . Snorkel terminations 
are available for applications which may require vertical rise on the building 
exterior . The components listed below come in a galvanized finish . Most 
of the components are also available in a painted black finish . Add a “B” 
to the end of the part number when ordering if a black part is desired .

6-5/8" x 4" Secure Vent Pipe by Security Chimneys 

 

Part Number 

Description

 

SV4L6 

6" Pipe Length

 

SV4L12 

12" Pipe Length

 

SV4L24 

24" Pipe Length 

 

SV4L36 

36" Pipe Length 

 

SV4L48 

48" Pipe Length 

 

SV4LA 

6" Pipe, Adjustable

 

SV4LA12 

12" Pipe, Adjustable

 

SV4FA 

Flashing, 1/12 to 176/12 Roof Pitch

 

SV4FB  

Flashing, 8/12 to 12/12 Roof Pitch

 

SV4RSM 

Wall Radiation Shield

 

SV4E46 

45° Elbow

 

SV4E90 

90° Elbow

 

SV4VS 

Vinyl Shield Protector

 

SV4FC 

Storm Collar

 

SV4CGV 

Vertical Termination Cap

 

SV4BF 

Firestop

 

SV4BM 

Wall Band

Reducer (available from Lennox Hearth Products only)

 

75247 

8" x 5"  to  6-5/8" x 4" Reducer

6-5/8" x 4" GS Pipe by Dura-Vent

 

Part Number 

Description

 

908 

6" Pipe Length

 

907 

9"  Pipe Length

 

906 

12" Pipe Length

 

904 

24" Pipe Length

 

903 

36" Pipe Length

 

902 

48" Pipe Length

 

911 

11" to 14-5/8" Pipe, Adjustable

 

912 

12" to 17" Pipe, Adjustable

 

917 

17" to 24" Pipe, Adjustable

 

942 

Wall Thimble

 

945 

45° Elbow

 

943 

Flashing, 0/12 to 6/12 Roof Pitch

 

943S 

Flashing, 7/12 to 12/12 Roof Pitch

 

953 

Storm Collar

 

963 

Ceiling Firestop

 

988 

Wall Strap

 

980 

Vertical Termination Cap

 

991 

Vertical Termination Cap (High Wind)

Summary of Contents for RAVELLE 42

Page 1: ...mmediately call your gas supplier from a neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department Installation and service must be perfo...

Page 2: ...13 Hearth Extension Considerations 13 Facing Installation Considerations 14 Face Installation 16 Vent Installation Application 17 Vent Parts List 17 Vent Considerations 19 Horizontal Vent Installation...

Page 3: ...s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con el vidrio y prevenir las q...

Page 4: ...la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette mesu...

Page 5: ...rruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la ch...

Page 6: ...ge to this appliance and or its operating controls is dangerous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning...

Page 7: ...be replaced prior to operating the appliance Goldandnickelplatedsurfacesmustbe cleaned with glass cleaner and a clean soft cloth before firing the first time or fingerprints will remain permanently N...

Page 8: ...D APPROVALS Must conform with all local state and national installation codes In the absence of local codes the installation must conform with National Fuel Gas Code ANSI Z223 1 latest edition also kn...

Page 9: ...l It is also important to note the thickness of the wall Before cutting the vent hole through the wall make sure ALL vent and termination clearances will be met see Pages 21 and 23 Electrical The stan...

Page 10: ...0mm Mantel The drawing at the lower right shows the minimum distances from the base of the fireplace to combustible mantel and facing material Combustible materials may be placed above and within the...

Page 11: ...to the valve wThe electrical power supply wiring should be routed to the right rear of the unit Note The fireplace may be placed directly on wood or non combustible flooring but NOT on vinyl floor co...

Page 12: ...20 3 4 527 47 3 4 1213 35 1 2 902 2 51 34 864 41 1041 38 1 4 972 30 762 43 1092 30 762 3 1 2 89 9 1 2 241 10 3 4 273 72 1 2 1842 6 7 8 175 18 3 16 462 32 5 16 821 3 1 2 89 5 127 6 1 4 159 2 1 4 57 GAS...

Page 13: ...fireplace must be raised the thickness of that hearth extension less the 7 8 22 mm For example if a 2 7 8 73 mm thick cultured stone is to be placed on the floor to serve as the hearth extension then...

Page 14: ...ce face see below Facing Installation Considerations Non combustible cement board such as Wonderboard Durock or Har dybacker must extend 10 254 mm above the 1 25 mm top reveal and a minimum of 3 76 mm...

Page 15: ...must be placed around the face A template Arch 75098 Foundry 75035 and Classic Louver 75101 should be used while installing the facing material Templates for the various faces may be purchased from y...

Page 16: ...e place face The acid wash will tarnish the face Consult your masonry installer Face Installation A number of different faces are available for the Ravelle 42 gas fire place however all the faces are...

Page 17: ...ventcomponentpartnotapprovedormanufactured by the approved vent manufacturer Installation other than as instructed by Lennox Hearth Products and the vent manufacturer s instructions Vent Parts List Se...

Page 18: ...h Wind 1250 Vinyl Siding Standoff Vent Parts List Vertical Direct vent pipe by Security Chimneys or Dura Vent may be used with the Ravelle 42 gas fireplace Please see the lists below to verify the com...

Page 19: ...le from the outside on the pipe or fittings They may be located by examining the inside of the female ends Supports Horizontal runs of vent must be supported every three feet Wall straps are available...

Page 20: ...ent termination on an exterior wall must meet all local and national building codes and must not be blocked or obstructed For allowable external vent terminations locations see the diagram on Page 23...

Page 21: ...and 23 the burner flame appearance should be evaluated to determined if the flue restrictors need to be set to a different position to adjust for variables in your installation Light the appliance an...

Page 22: ...hown below Use the restrictor positions indicated If the fireplace is vented with an elbow directly off the top of the flue collar and three to four feet of horizontal pipe is used then no restrictor...

Page 23: ...above meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to ser...

Page 24: ...r natural gas use only For LP conversions remove the air shield 5 Place Logs 3 4 and 5 on tab inserts Important Maintain a 1 4 6 4mm air space along the entire length of log Glowing Embers rockwool In...

Page 25: ...replace must be turned off at the electrical panel before any connections are made The loop of wire with the label attached E in Figure 29 may be cut and the wire leads from the wall mounted speed con...

Page 26: ...essure with the fireplace burning insert a small flat bladed screwdriver into the tap and turn a half turn counterclockwise Cover the tap with the line from a manometer and read the pressure Closethet...

Page 27: ...rminated with a grill When the fireplace is burning with or without the fireplace blower running air is drawn from a distant room lowering the pressure in that room through the return air duct into th...

Page 28: ...n Sheet Metal Screws One Wire Clamp The Forced Air Duct System allows you to direct warm air from your Ravelle 42 DV fireplace using a 150 CFM blower through six inch ducts into other rooms in the hou...

Page 29: ...additional piece of flooring F below should also be cut out for the blower box to slide through Save this piece F and nail it back in place after the blower box is installed 3 Slide the blower box thr...

Page 30: ...each joint 5 Secure the ducting to prevent sagging Wiring of the Forced Air Duct System Disconnect the electrical supply to the fireplace at the electrical panel prior to wiring the forced air system...

Page 31: ...nobs come with the kit Select the cover desired and fasten the speed control and cover to the box with the screws supplied Push the desired knob onto the shaft of the speed control 4 Remove the four s...

Page 32: ...le fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer la poussi re et les traces de...

Page 33: ...or attempted repair may result in a fire or explosion D DO NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to repla...

Page 34: ...and a hazardous situation See Figure 45 showing proper flame appearance When testing for proper operation If an optional thermostat is installed adjust it to its highest temperature setting Visually...

Page 35: ...h a 200 CFM blower with a variable speed control and an automatic temperature activated on off snap switch Operation 1 After the fireplace warms up a heat activated switch will turn on the blower A bl...

Page 36: ...Be sure to set the rocker switch to the OFF position when using the thermostat or remote control and set the thermostat or remote control to the lowest temperature when you wish to use the rocker swit...

Page 37: ...ot air outlet vents for lint or other accumulations Never block or restrict vent openings obstruct flow of ventilation air or use vents other than those approved for use with this appliance o Check th...

Page 38: ...led cover through which the valve control knobs protrude by removing the two allen head screws securing it and slide it off the valve knobs 6 Mark and disconnect wires on valve terminals 1 and 3 conne...

Page 39: ...atch light pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electro...

Page 40: ...f form 775241M 75064 RAVL42 CK NG to LP Conversion Kit NG to LP ref form 775250M Misc 75259 NP RAVL30 42 Nail Plates 4 x 12 galvanized 75247 Reducer 8 6 5 8 Reducer 8 to 6 5 8 75134 RAVL42 DUCTKT Forc...

Page 41: ...ushed Nickel 75317 AI42 TUSCAN BKNKL TUSCAN Black Nickel Screen Kit ref form 775289M 75029 Screen Face double Door black 43 1 4 W x 31 7 8 H INSETS Required Includes 1 Top and 1 Bottom Inset ref form...

Page 42: ...ET CGA 2 17 M91 CET APPAREIL DOIT TRE INSTALL CONFORM MENT AUX EXIGENCES DES CODES R GIONAUX ET DU CODE D INSTALLATION ANSI NFPA 54 DERNI RE DITION ETATS UNIS OU CAN CGA B149 1 DERNI RE DITION CANADA...

Page 43: ...nob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 9 If knob does not pop up when released stop and immediately call your service technician or gas supplier LIGH...

Page 44: ...cien qualifi ou le fournisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technicien qualifi ou le fourni...

Page 45: ...NOTES 45...

Page 46: ...d the following important information aboutyourappliance PleasecontactyourLennoxHearthProductsdealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please c...

Reviews: