Lennox Hearth Products LMDTV-3328CNM Homeowner'S Care And Operation Instructions Manual Download Page 22

22

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Inspecting/Cleaning Burner, Logs 

and Controls

Qualifi ed Service Technician

Inspect valve and ensure it is properly operating.  Check piping 

for leaks.  Vacuum the control compartment, fi replace logs and 

burner area.

Check Flame Patterns and Flame 

Height

Qualifi ed Service Technician

Refer to 

Figure 10 (LMDV-3328 & LMDV-3530) or Figure 11 

(LMDV-4035) 

on

 Page 11 

and verify the fl ame pattern and height 

displayed by the appliance conforms to the picture.  Flames 

must not impinge on the logs.  Ensure fl ames are steady (not 

lifting or fl oating).

Inspecting/Cleaning Pilot and Burner

Qualifi ed Service Technician

Refer to 

Figure 13 (

SIT Millivolt

), Figure 14 (

Honeywell Mil-

livolt

) or Figure 15 (

Electronic

) on Page 12

. Remove any surface 

build-up on pilot and burner assembly.  Wipe the pilot nozzles, 
igniter/fl ame rod and hood.  Ensure the pilot fl ame engulfs the 
fl ame sensor as shown.

Checking Vent System

Qualifi ed Service Technician

Inspect the vent system at the top and at the base (within the 

fi rebox) for signs of blockage or obstruction.  Look for any signs 

of dislocation or deterioration of the vent components.  

Note

:  

Excessive condensation can cause corrosion of caps, pipe & 

fi ttings (excessive condensation can be caused by long lateral 

runs, too many elbows and/or exterior portions of the system 

being exposed to cold weather).  Also inspect wall straps or 

plumbers's tape to ensure it is secure and in place.

Appliance Checkout

Qualifi ed Service Technician

Perform the appropriate appliance checkout procedure detailed 

in this manual.

Replacing Rockwool Ember Materials

Homeowner/Qualifi ed Service

Technician

Remove old ember materials (rockwool) and vacuum the ember 
placement area.  Place new embers as described and shown in   

Figures 8 & 9.

Periodically

 (After the Burning Season)

MAINTENANCE TASK

ACCOMPLISHING PERSON

PROCEDURE

Cleaning  Firebox  Interior

Homeowner

Carefully remove logs, rockwool, volcanic stone and vermiculite.  

Vacuum out interior of the fi rebox.  Clean fi rebox walls and log 

grate.  Replace logs, rockwool, vermiculite and volcanic stone 

as detailed in this manual.

Check Flame Patterns and Flame 

Height

Homeowner

Refer to 

Figure 10 (LMDV-3328 & LMDV-3530) or 11 (LMDV-

4035) on Page 11

 and verify the fl ame pattern and height dis-

played by the appliance conforms to the picture. Flames must 

not impinge on the logs.

Checking Vent System

Homeowner

Inspect the vent system at the top and at the base (within the 

fi rebox) for signs of blockage or obstruction.  Look for any signs 

of dislocation of the vent components.

Cleaning Front Glass Enclosure Panel

Homeowner

Clean as necessary following the directions provided in this 

manual.  

DO NOT  TOUCH OR ATTEMPT TO CLEAN GLASS 

WHILE HOT

.

Annually

 (Before the onset of the Burning Season)

MAINTENANCE SCHEDULE

Summary of Contents for LMDTV-3328CNM

Page 1: ...ACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will retain...

Page 2: ...manual For assistance or additional information consult a qualified installer service agency or the gas supplier SAFETY WARNIING INFORMATION WARNING Thesefireplacesareventedheat ers Do not burn wood...

Page 3: ...uction Page 3 General Information Page 3 Gas Controls Access Page 4 Operation Care of Your Appliance Page 4 Variable Flame Adjustment Page 5 Maintenance Page 6 Front Glass Enclosure Panel Removal and...

Page 4: ...test edition Gas Pressure Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Propa...

Page 5: ...and off with the wall switch or remote control If your electronic appliance is not equipped with a wall switch or remote control the main burner must be turned off and on with the gas control switch T...

Page 6: ...improper and dangerous opera tion Verify proper operation after servicing Inspect and clean all wire connections Ensure that there is no melting or damage Inspection should include Terminals at the Va...

Page 7: ...ERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front glass enclosure panel or any of the panels is removed the flame...

Page 8: ...ogs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested for le...

Page 9: ...VolcanicStoneandLogsintheorder shown here 1 through 6 and per the instructions onPage8 A E B C D Vermiculite Volcanic Stone Embers DO NOT PLACE EMBERS OVER GAS SLOTS 1 2 3 4 5 6 The2notchesonlogbottom...

Page 10: ...rrespond to photos InstalltheEmbers Vermiculite VolcanicStoneandLogsintheorder shownhere 1through6 andper theinstructionsonPage8 D C E A B 1 2 3 4 5 6 Vermiculite Volcanic Stone DONOTPLACEEMBERSOVERGA...

Page 11: ...uidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are not impinging on any of the logs If the log set is properly positioned and a sooting condi...

Page 12: ...flame appearance is achieved 4 Leave the control knob off pilot on in the ON position and the burner OFF ON switch OFF remote switches if applicable 5 When satisfied that the burner flame ap pearance...

Page 13: ...tch CAUTION Label all wires prior to discon nection when servicing con trols Wiring errors can cause improper and dangerous appli ance operation Figure16 Electronic Wiring Diagram Honeywell Showing Bl...

Page 14: ...installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch Standard Remote Control System The Model RCL Standard...

Page 15: ...rass H0950 SD40C 40 Sq Doors Charcoal LMDV 4035 H0951 SD40TI 40 Sq Doors Textured Iron H0952 SD40SP 40 Sq Doors Satin Pewter H0953 SD40AB 40 Sq Doors Antique Brass Style View Doors Square Pane Design...

Page 16: ...ariable Speed with Wall Switch 36 Pack H0543 FBK 250 36 Blower Kit Variable Speed with Thermo Snap Switch 36 Pack ref Form 750 028M 750 029M Variable Speed Wall Switch Provides variable speed control...

Page 17: ...s are available in two styles These hoods are designed to be fitted to the glass viewing sides of the appliance In addition to providing an aesthetically pleasing appearance to your appliance installa...

Page 18: ...your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair ma...

Page 19: ...un commutateur lectrique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagni...

Page 20: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Page 21: ...pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mu...

Page 22: ...oo many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service...

Page 23: ...itch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote...

Page 24: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Page 25: ...Lennox Nameplate Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT H1657 1 88J53 1 13 Piezo Igniter w wire 91K94 1 91K94 1 14 Pi...

Page 26: ...26 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE REPLACEMENT PARTS 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20 31 21 8 LMDV 4035 LMDVT 3328 LMDVR 3530...

Page 27: ...27 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE NOTES...

Page 28: ...N 875 028M REV D 05 2006 LennoxHearthProductsreservestherighttomakechangesatanytime withoutnotice in design materials specifications prices and also to discontinue colors styles and products Consult y...

Reviews: