background image

16

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

3 Piece Trim Kit

Cat. No.

Model No.

Description

H0453

TK33PB3

33” Polished Brass, 
LMDVT-3328, LMDVR-3328

96K21

TK35PB3

35” Polished Brass,
LMDV-3530

96K22

TK40PB3

40" Polished Brass, 
LMDV-4035

H1813

TK33BS3

33” Brushed Stainless, 
LMDVT-3328, LMDVR-3328

H1815

TK35BS3

35” Brushed Stainless,
LMDV-3530

H1816

TK40BS3

40", Brushed Stainless, 
LMDV-4035

H4820

TK33C3

33” Charcoal,
LMDVT-3328, LMDVR-3328

H4821

TK35C3

35” Charcoal,
LMDV-3530

H4823

TK40C3

40" Charcoal,
LMDV-4035

(ref. Form # 750,147M)

4 Piece Trim Kit

Cat. No.

Model No.

Description

96K17

 TK35PB4

35” 4 Piece Finish Trim Kit, 
Polished Brass, LMDV-3530

96K18

TK40PB4

40” 4 Piece  Finish Trim Kit, 
Polished Brass, LMDV-4035

(ref. Form # ii-9299)

Forced Air Kit

The FBK-100 blower provides constant velocity forced 
air circulation. The FBK-200 assembly with variable 
speed, wall-mountable switch provides variable speed 
forced air circulation. The FBK-250  assembly with 
variable speed unit-mountable switch, also provides 
variable speed forced air circulation.

Forced Air Blower Kits

Cat. 

No.

Model No.

Description

80L84

FBK-100

Blower, Standard
(single speed)

80L85

FBK-200

Blower, Variable Speed 
(w/wall-mounted switch)

80L86

FBK-250

Blower, Variable Speed 
(w/unit-mounted switch)

94L89

FBK-100-36

Blower, Standard, 36 Pack

94L90

FBK-200-36

Blower Kit - Variable Speed 
with Wall Switch 36 Pack

H0543

FBK-250-36

Blower Kit - Variable Speed 
with Thermo Snap Switch 
36 Pack

(ref. Form # 750,028M & 750,029M)

Variable Speed Wall Switch

Provides variable speed control if optional blower 
kit is purchased.

Variable Speed Wall Switch

Cat. No.

Model No.

Description

045571H

VSWS

Rocker Switch Kit

Brickaded Wall Liner Kits

Cat. No.

Model No.

Description

H0912

MBLK-33T

Brick Liner Kit, Top Vent,
LMDVT-3328

H0918

MBLK-33R

Brick Liner Kit, Rear Vent,
LMDVR-3328

H0913

MBLK-35

Brick Liner Kit, Top/Rear,
LMDV-3530

H0914

MBLK-40

Brick Liner Kit, Top/Rear,
LMDV-4035

Brickaded Panel Liner Kit

The brickaded liner kits include ceramic panels as 
shown here.  The panels have brick-like features in relief.

(ref. Form # 750,160M)

Polished Brass 3-Piece Trim Kit

This kit contains brass trim pieces used to fi nish the 
gaps between the wall board and the fi replace, provid-
ing the appliance a brass perimeter highlight.  This kit 
contains the trim pieces and these instructions

Polished Brass 4-Piece Trim Kit

This kit contains brass trim pieces used to fi nish the 
gaps between the wall board and the fi replace, provid-
ing the appliance a brass perimeter highlight.  This kit 
contains the trim pieces and these instructions

ACCESSORY COMPONENTS

OFF/ON Wall Switch Kit

 

The OFF/ON wall switch kit may be used to control 

the operation of the fi replace burner. Install the 
OFF/ON wall switch in a convenient location near 
the fi replace.

White Wall Switch Kit

Cat. No.

Model No.

Description

85L87

FWSK

OFF/ON Wall Switch Kit

Summary of Contents for LMDTV-3328CNM

Page 1: ...ACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will retain...

Page 2: ...manual For assistance or additional information consult a qualified installer service agency or the gas supplier SAFETY WARNIING INFORMATION WARNING Thesefireplacesareventedheat ers Do not burn wood...

Page 3: ...uction Page 3 General Information Page 3 Gas Controls Access Page 4 Operation Care of Your Appliance Page 4 Variable Flame Adjustment Page 5 Maintenance Page 6 Front Glass Enclosure Panel Removal and...

Page 4: ...test edition Gas Pressure Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Propa...

Page 5: ...and off with the wall switch or remote control If your electronic appliance is not equipped with a wall switch or remote control the main burner must be turned off and on with the gas control switch T...

Page 6: ...improper and dangerous opera tion Verify proper operation after servicing Inspect and clean all wire connections Ensure that there is no melting or damage Inspection should include Terminals at the Va...

Page 7: ...ERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front glass enclosure panel or any of the panels is removed the flame...

Page 8: ...ogs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested for le...

Page 9: ...VolcanicStoneandLogsintheorder shown here 1 through 6 and per the instructions onPage8 A E B C D Vermiculite Volcanic Stone Embers DO NOT PLACE EMBERS OVER GAS SLOTS 1 2 3 4 5 6 The2notchesonlogbottom...

Page 10: ...rrespond to photos InstalltheEmbers Vermiculite VolcanicStoneandLogsintheorder shownhere 1through6 andper theinstructionsonPage8 D C E A B 1 2 3 4 5 6 Vermiculite Volcanic Stone DONOTPLACEEMBERSOVERGA...

Page 11: ...uidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are not impinging on any of the logs If the log set is properly positioned and a sooting condi...

Page 12: ...flame appearance is achieved 4 Leave the control knob off pilot on in the ON position and the burner OFF ON switch OFF remote switches if applicable 5 When satisfied that the burner flame ap pearance...

Page 13: ...tch CAUTION Label all wires prior to discon nection when servicing con trols Wiring errors can cause improper and dangerous appli ance operation Figure16 Electronic Wiring Diagram Honeywell Showing Bl...

Page 14: ...installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch Standard Remote Control System The Model RCL Standard...

Page 15: ...rass H0950 SD40C 40 Sq Doors Charcoal LMDV 4035 H0951 SD40TI 40 Sq Doors Textured Iron H0952 SD40SP 40 Sq Doors Satin Pewter H0953 SD40AB 40 Sq Doors Antique Brass Style View Doors Square Pane Design...

Page 16: ...ariable Speed with Wall Switch 36 Pack H0543 FBK 250 36 Blower Kit Variable Speed with Thermo Snap Switch 36 Pack ref Form 750 028M 750 029M Variable Speed Wall Switch Provides variable speed control...

Page 17: ...s are available in two styles These hoods are designed to be fitted to the glass viewing sides of the appliance In addition to providing an aesthetically pleasing appearance to your appliance installa...

Page 18: ...your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair ma...

Page 19: ...un commutateur lectrique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagni...

Page 20: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Page 21: ...pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mu...

Page 22: ...oo many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service...

Page 23: ...itch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote...

Page 24: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Page 25: ...Lennox Nameplate Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT H1657 1 88J53 1 13 Piezo Igniter w wire 91K94 1 91K94 1 14 Pi...

Page 26: ...26 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE REPLACEMENT PARTS 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20 31 21 8 LMDV 4035 LMDVT 3328 LMDVR 3530...

Page 27: ...27 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE NOTES...

Page 28: ...N 875 028M REV D 05 2006 LennoxHearthProductsreservestherighttomakechangesatanytime withoutnotice in design materials specifications prices and also to discontinue colors styles and products Consult y...

Reviews: