8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
p
ipe
C
learanCes
All installations using a vertical termination cap must
maintain one inch clearance between the direct vent pipe
and combustibles. For horizontal runs of pipe, one inch of
clearance to combustibles on the sides and bottom, and
two inches on the top of the pipe is required. See page 14
for allowable pipe configurations.
5-5/8”
(14mm)
10”
(54mm)
8-7/8”
(5mm)
Leg on Combustible
Carpet
1-1/” Maximum
C
learanCes
to
C
ombustibles
Minimum clearances to combustible materials in inches
(millimeters):
Parallel Installation
Corner Installation
a
lCove
dimensions
The minimum width between the alcove side walls is 51”
1295mm). The minimum height of the alcove is 46” (1168mm)
and the maximum depth is 35” (889mm).
f
loor
p
roteCtion
A non-combustible hearth pad is not required. This stove
may be installed on a combustible surface as long as the
combustible material (such as carpeting) does not extend
1-1/2” (38mm) vertically above the bottom of the base.
Also, the floor beneath the stove must be stable, level, hard,
and strong enough to support the stove without a tipping
hazard.
51”
(195mm)
Min.
5”
(889mm)
Max.
4”
(118mm)
Min.
Alcove Dimensions
Figure 4
Figure 5
Figure
” (51mm)
15” (81mm)
Min.
4-1/4”
(1mm)
Min.
90°
10”
(54mm)
Figure 7