NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SAFETY / LISTING LABEL - Ravenna IPI

 

Ravenna™ IPI

MANUFACTURED BY:

LENNOX HEARTH PRODUCTS

1502 14TH ST NW

AUBURN, WA., USA 98001

 

RDV IPI

SERIAL

 NO.

4002589

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL

CONFORMS TO ANSI STD Z21.88: CERTIFIED TO CSA STD 2.33 & CGA STD 2.17.

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY.  IF NOT, FOLLOW THE CURRENT ANSI Z223.1/NFPA 

54-LATEST EDITION (USA) OR CAN/CGA  B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE 

WITH THE MANUFACTURER’S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES ONLY - MASONRY 

OR FACTORY BUILT.  THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS. 

THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN 

AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE OWNER’S 

MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, 

FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST EDITION (CANADA).

FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.

MINIMUM CLEARANCES

WARNING: IF UNIT IS CONVERTED TO AN RDV40 IPI FROM AN RDV33 IPI ENSURE THAT THE 

CLEARANCES TO COMBUSTIBLES ARE CORRECT FOR RDV40 IPI.

RATINGS

Ravenna 40 IPI  (RDV40 IPI)

Ravenna 33 IPI (RDV33 IPI)

NATURAL GAS

LP GAS

NATURAL GAS

LP GAS

MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*

40,000/28,000

37,500/26,000

33,000/24,000

33,000/24,000

MANIFOLD PRESSURE (IN. WC)

3.5

10.0

3.5

10.0

MIN. INLET PRESSURE (IN. WC)

5.0

10.5

5.0

10.5

ORIFICE (DMS) 0-2,000 FT (0-610 M)*

1/8”

#49

#36

#51

*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M. ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS

CHIMNEY - USE 3" (76 MM) GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635.  

THIS APPLIANCE  MUST  BE  PROPERLY  CONNECTED  TO A  VENTING  SYSTEM  IN ACCORDANCE  WITH  THE  MANUFACTURER’S 

INSTALLATION INSTRUCTIONS.

FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 1,000 FT (405 M).

CAUTION:

 HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP 

CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY. 

KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING INSTRUCTIONS 

ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY. DO NOT 

OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S) 

SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE 

INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS 

APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE 

AGENCY OR GAS SUPPLIER.

DO NOT REMOVE OR COVER THIS LABEL

Part No. 580413-01  Rev. NC, 10/2011

IGN 11-6179

DATE OF MANUFACTURE / DATE DE FABRICATION

2011

2013

2014

2012

JAN

FEB MAR

APR MAY

JUN

JUL

AUG SEP

OCT

NOV DEC

MODEL

Note: Hearth protection to be min. 

3/8” (10mm) thick non-combustible 

or equivalent, with a k factor of .84.

A

D

B

E

C

CL

MANTEL

TRIM

MINIMUM FIREPLACE SIZES REQUIRED

 ....................

  RDV40 IPI 

RDV33 IPI

Front Opening ...................................................................  31.50” (800mm) 

31.50” (800mm)

Height .................................................................................  19.50” (495mm) 

19.50” (495mm)

Rear Width  ........................................................................  19.00” (483mm) 

19.00” (483mm)

Depth  .................................................................................  16.00” (406mm) 

16.00” (406mm)

MINIMUM CLEARANCES TO COMBUSTIBLES

  A = Top Facing to Bottom of Appliance .....................  35.5" (902mm) 

31.5" (800mm)

  B = Side Facing or Side Wall to Center of Glass ......  25.5" (648mm) 

25.5" (648mm)

* C = 10.5” (267mm) Mantel  to Bottom of Appliance .  43" (1092mm) 

39" (991mm)

HEARTH PROTECTION

  D = Vertical Distance from base of appliance       0"              2”              4”                0"              2”              4”

    to  Hearth Extension .......................................... (0mm)    (51mm)   (102mm)     (0mm)      (51mm)   (102mm) 

 

  E = Minimum Horizontal Distance 

   14"            10”              0”                13"           10”             0”

    from Front of Appliance ..................................  (356mm)  (254mm)   (0mm)      (330mm)  (254mm)    (0mm)

MANTEL

FACING

*See owner’s manual for additional mantel clearances and options.

FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.

CONFORME AU STANDARD ANSI Z21.88; CERTIFIÉ AU STANDARD CSA 2.33 ET CGA 2.17.

CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI 

NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA). CET APPAREIL DOIT ÊTRE INSTALLÉ 

SELON LES DIRECTIVES D’INSTALLATION DU FABRICANT. POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE SOLIDE 

SEULEMENT - DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE. CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS CONÇU POUR ÊTRE 

UTILISÉ AVEC DES FILTRES À AIR.

CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE ET PEUT ÊTRE INSTALLÉ DANS 

UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE PERMETTENT. VOIR LE MANUEL 

D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES TYPES DE GAZ À 

MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.

DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.

SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE CONFORMES 

AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.

DANGER:

 CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES 

ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS LA PIÈCE. 

GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES 

INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT TEMPS. VOIR LES MANUELS 

D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. SEUL LE PANNEAU VITRÉ FOURNI PAR LE MANUFACTURIER 

PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. EN AUCUN CAS, L’APPAREIL NE PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE 

BRISÉE. LE REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
AVERTISSEMENT: UNE INSTALLATION INADÉQUATE DE MÊME QU’UN AJUSTEMENT, UNE MODIFICATION, UNE RÉPARATION OU UN 

ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. RÉFÉREZ-VOUS AU MANUEL 

D’ENTRETIEN LIVRÉ AVEC CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE 

DE SERVICE OU UN FOURNISSEUR DE GAZ.

IGN 11-6179

N’ENLEVEZ PAS OU NE COUVREZ PAS CETTE ÉTIQUETTE

No. pièce #580413-01 Rev. NC, 10/2011

 

MODÈLE

FABRIQUÉ PAR:

LENNOX HEARTH PRODUCTS

1502 14TH ST NW

AUBURN, WA., USA 98001

Le numéro de série est indiqué dans la 

section anglophone de cette étiquette

SERIAL

 NO.

4002589

CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT CETTE 

ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.

La date de fabrication est indiquée dans la section anglophone de cette étiquette

Ravenna™ IPI

SPÉCIFICATIONS

Ravenna 40 IPI (RDV40 IPI)

Ravenna 33 IPI (RDV33 IPI)

GAZ NATUREL

GAZ PROPANE

GAZ NATUREL

GAZ PROPANE

ENTRÉE MAX/MIN BTU/HR 0-4500 pi (0-1370 M)*

40000/28000

37500/26000

33000/24000

33000/24000

PRESSION À LA SORTIE  (IN. WC/C.E.)

3,5

10,0

3,5

10,0

PRESSION MINIMUM D’ENTRÉE DU GAZ (IN. WC/C.E.)

5,0

10,5

5,0

10,5

ORIFICE (DMS) 0-4500 pi (0-1370 M)*

1/8”

#49

#36

#51

*L’APPAREIL PRÉUSINÉ EST MUNI D’ÉQUIPEMENT POUR 0-2000 PIEDS (0-610 M). AU CANADA 0-4500 PIEDS (0-1370M).

SPÉCIFICATIONS ÉLECTRIQUE 120 VCA, 60 HZ, MOINS DE 2 AMPÈRES 

CHEMINÉE -  POUR LA SORTIE D’ÉVACUATION DES GAZ UTILISEZ UNE GAINE DE TUBAGE CERTIFIÉ SELON UL1777 OU ULC S635.  

CET APPAREIL  DOIT  ÊTRE  RELIÉ  À  UN  SYSTÈME  D’ÉVACUATION  TEL  QUE  SPÉCIFIÉ  DANS  LE  MANUEL  D’INSTALLATION  DU 

FABRICANT.

EN ALTITUDE, AU-DELÀ DE 2000 PI/610 M, (AU CANADA 0-4500 PI/0-1370M) LA CAPACITÉ ÉNERGÉTIQUE DE L’APPAREIL DIMINUE DE 

QUATRE (4)% POUR CHAQUE 1000 PI (405 M).

SI LE MODÈLE RDV33 IPI EST CONVERTI COMME MODÈLE RDV40 IPI,  ASSUREZ VOUS QUE LES 

DÉGAGEMENT AUX COMBUSTIBLES SONT RESPECTER SELON LE MODÈLE RDV40 IPI.

DÉGAGEMENTS MINIMUMS

Note: Extension d’âtre fabriqué avec 

3/8” (10mm) minimum de matériaux 

non-combustible ou équivalent 

possédant un facteur k de 0.84.

A

D

B

E

C

CL

DIMENSIONS MINIMUMS DE FOYER REQUISES

 .......

  RDV40 IPI 

RDV33 IPI

Ouverture avant ................................................................  31.50” (800mm) 

31.50” (800mm)

Hauteur ..............................................................................  19.50” (495mm) 

19.50” (495mm)

Largeur arrière  .................................................................  19.00” (483mm) 

19.00” (483mm)

Profondeur  .......................................................................  16.00” (406mm) 

16.00” (406mm)

DÉGAGEMENTS AUX COMBUSTIBLES

  A = Du bas de l’appareil au dessous de 

    la finition supérieure ..............................................  35.5" (902mm) 

31.5" (800mm)

  B = Du centre de la vitre à la finition latérale .............  25.5" (648mm) 

25.5" (648mm)

* C = 

10.5” (267mm) manteau de foyer à partir 

   

de la base

................................................................  43" (1092mm) 

39" (991mm)

PROTECTION DU FOYER

  D = Distance verticale de la base de

 .................

        0"               2”              4”                0"              2”               4”

    de l’appareil à l’extension d’âtre ....................     (0mm)    (51mm)   (102mm)     (0mm)      (51mm)    (102mm) 
  E = Extension d’âtre min. à l’avant

 ....................

     14"            10”               0”                13"           10”             0”

    de l’appareil......................................................... (356mm)  (254mm)    (0mm)      (330mm)  (254mm)    (0mm)

MANTEAU 

DE FOYER

PIÉCE DE

FINITION

*Voir le manuel d’entretien pour les informatinos supplémentaires reliées aux distances à respecter pour le manteau de foyer.

2012  2013  2014  2015

Summary of Contents for Elite RAVENNA IPI

Page 1: ...rnis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou...

Page 2: ...40 TCC models only 11 Installation 11 17 Venting Installation 11 Zero Clearance Fireplace Installation 12 Firebox Panel Kit and Log Set Installation 13 14 Surround Panels Installation 14 Operating Op...

Page 3: ...ller service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Page 4: ...connected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance is only...

Page 5: ...panel de control para quitarelpolvoyaceite Peguelaetiquetaadyacente alinterruptordecontroldelquemadorquecontrola elartefacto FiguraA Seleccioneelidiomaquem s se habla en la casa 2 Identifique el tran...

Page 6: ...or factory built fireplaces Fireplace Requirements These heaters are designed to be installed into an existing masonry fireplace built to UBC 37 or ULC S628 standards or factory built solid fuel wood...

Page 7: ...zed testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified by Intertek Testing Services Portland...

Page 8: ...kaging List Insert Body Packaging List 1 Insert Body with Burner Cassette 1 Log Set 1 Bag of Embers 1 Power Cord 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive w...

Page 9: ...A 31 1 2 800mm Front Opening Width B 19 1 2 495mm Height C 19 483mm Rear Width D 16 406mm Fireplace Depth Top View Left Side View Right Side View Front View A B C D Figure 3 Minimum Fireplace Cavity F...

Page 10: ...note that the RDV33 IPI TCC mantel clearances are 4 less than the RDV40 IPI TCC mantel clearances as shown in Figure 4A RDV40 IPI TCC and Figure 4B RDV33 IPI TCC CLEARANCES TO COMBUSTIBLES RDV40 IPI T...

Page 11: ...acturer s instructions for installation and vent termination These appliances are approved for use with the following vent kits Amerivent Flex Liner 3 X 35 3AFL 35 Adaptor w Flashing 4DCAT33 Terminati...

Page 12: ...e sealed around the vent pipes Use a non combustible seal off plate i e 22 gage sheet steel or unfaced fiberglass insulation 8 lb per square foot density minimum to seal around the vent pipes Whicheve...

Page 13: ...o Optional 33 000 BTU Natural Gas Input To convert input from 40 000 BTU s to 33 000 BTU s Assuming the front door is already removed 1 Remove the log rack Use a 5 32 allen wrench by removing two scre...

Page 14: ...oundpanelsinfrontoftheholesonthesurroundbrackets Next insert two slotted 1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss s...

Page 15: ...ns 1 Carefully cut out the burner switch hole in the control panel label 2 Disconnect the switch from the extension wires to which it is attached then disconnect these wires from the green and white w...

Page 16: ...n retighten if necessary If the pressure is not sufficient make sure the gas supply line is large enough the supply regulator is properly adjusted and the total gas load for the residence does not exc...

Page 17: ...r will result in bigger flames and more color To adjust the air shutter insert a regular screwdriver into the slide adjustment and slide it side to side see Figures 19a and 19b CAUTION The air shutter...

Page 18: ...mmande Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 3 Si vous ne trouvez pas les tiquettes veuillez appele...

Page 19: ...power to the appliance 8 Turn the burner ON OFF switch in the control compartment to ON After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner 9 If...

Page 20: ...high altitudes Figure 21A RDV33 40 IPI Models Figure 21B RDV33 40 TCC Models IMPORTANTNOTE Whenopeningthelowerdoorontheface while the insert is burning pull at the far left or far right vent openings...

Page 21: ...s to indicate that it is ready to synchronize with the Remote transmitter Install 3 AAA type batteries in the Remote transmitter battery bay located on the base of the Remote With the batteries alread...

Page 22: ...d off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position see...

Page 23: ...r proper main burner operation at both high and low flame OPERATION RDV33 40 TCC Models Only No Blue Flame Center Soot at Flame Tip Dark Orange Flame IMPROPERLY BURNING FLAME Soot above Flame Tip No S...

Page 24: ...MOTE RECEIVER BLOWER SPEED CONTROL PILOT ON AUTO SWITCH AC DC ADAPTER POWER OUTLET BOX 6 WHT 5 BLUE WHT BLK WHT BLK BLK BLK 4 GRN GRN 8 GRN 3 GRAY 14 RED 9 GRN 2 RED 1 RED 3 BLK 2 BLK 1 RED PILOT ROOM...

Page 25: ...TEMPERATURE N C NORMALLY CLOSED N O NORMALLY OPEN FEMALE DISCONNECT MALE DISCONNECT STUD CONNECTION REMOTE RECEIVER PILOT ON AUTO SWITCH FAN CONTROL MODULE POWER ADAPTOR BOX 6 WHT 5 BLUE 11 YLW 10 ORG...

Page 26: ...Never block or restrict vent openings obstruct flow of ventilation air or use vents other than those approved for use with this appliance o Check that the chimney and its outlet are open and free of...

Page 27: ...not attempt to substitute the materials used on these doors or replace cracked or broken glass Handle this glass with extreme care Glass is susceptible to damage Do not scratch or handle roughly while...

Page 28: ...e conversion Gas Conversion Kits Please see instructions provided with conversion kit Blower Removal Unplug the power supply cord from the electrical outlet prior to removing theblower Theblowercanbea...

Page 29: ...llation on Pages 13 and 14 The main Burner comes on but then goes out Gas is not reaching the appliance Loose wires to the valve or ignition module Pilot flame is not engulf ing the sensor Obstructed...

Page 30: ...f Switch Burner and Pilot Mode 24 H5655 Blower Speed Control Rheostat 25 H7274 Fan Control Module For TCC Models Only H8484 Pilot Ground Wire H8485 RDV IPI Blower Wiring Harness H8486 Wire Extension H...

Page 31: ...NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS RDV33 40 IPI RDV33 40 TCC 1 27 26 2 3 4 5 15 6 7 16 37 14 36 25 33 34 21 22 23 13 32 31 30 29 28 8 17 9 10 11 20 19 33 21 34 22 23 12 24...

Page 32: ...36 1 2 W x 23 1 2 H Orifice Kits Main Burner 33 000 BTU converts from standard 40 000 BTU input to optional 33 000 BTU input Cat No Description H5924 Orifice Main Burner 36 Natural Gas 33 000 BTU H592...

Page 33: ...RDV DBV FP2941 D 29 x 41 Black Trim Includes black trim x x x x x x x H8555 RDV DBV FP2948 D 29 x 48 Black Trim Includes black trim x x x x x x x H8556 RDV DBV FP3341 D 33 x 41 Black Trim Includes bl...

Page 34: ...CST GRL TRD3 Grill bars Traditional Box 3 of 3 Or 75091 PILCST GRL FIL3 Grill filigree Ornate Box 3 of 3 45 1 2 1156mm 44 1118mm 7 1 8 181mm 30 762mm 22 7 8 581mm uCast Surround Assembly For Pillared...

Page 35: ...E D INSTALLATION ANSI NFPA 54 DERNI RE DITION ETATS UNIS OU CAN CGA B149 1 DERNI RE DITION CANADA CET APPAREIL DOIT TRE INSTALL SELON LES DIRECTIVES D INSTALLATION DU FABRICANT POUR INSTALLATION DANS...

Page 36: ...NFPA 54 DERNI RE DITION ETATS UNIS OU CAN CGA B149 1 DERNI RE DITION CANADA CET APPAREIL DOIT TRE INSTALL SELON LES DIRECTIVES D INSTALLATION DU FABRICANT POUR INSTALLATION DANS DES FOYERS COMBUSTIBLE...

Page 37: ...plosion entra nant des dommages des blessures ou la mort A Cet appareil est muni d un dispositif d allumage qui allume automatiquement la veilleuse Ne tentez pas d allumer la veilleuse manuellement B...

Page 38: ...Page 30 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox Hearth Products distributor or dealer Parts will...

Reviews: