35
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
SAFETY / LISTING LABEL - Ravenna IPI
Ravenna™ IPI
MANUFACTURED BY:
LENNOX HEARTH PRODUCTS
1502 14TH ST NW
AUBURN, WA., USA 98001
RDV IPI
SERIAL
NO.
4002589
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL
CONFORMS TO ANSI STD Z21.88: CERTIFIED TO CSA STD 2.33 & CGA STD 2.17.
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, FOLLOW THE CURRENT ANSI Z223.1/NFPA
54-LATEST EDITION (USA) OR CAN/CGA B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER’S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES ONLY - MASONRY
OR FACTORY BUILT. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN
AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE OWNER’S
MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT,
FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST EDITION (CANADA).
FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.
MINIMUM CLEARANCES
WARNING: IF UNIT IS CONVERTED TO AN RDV40 IPI FROM AN RDV33 IPI ENSURE THAT THE
CLEARANCES TO COMBUSTIBLES ARE CORRECT FOR RDV40 IPI.
RATINGS
Ravenna 40 IPI (RDV40 IPI)
Ravenna 33 IPI (RDV33 IPI)
NATURAL GAS
LP GAS
NATURAL GAS
LP GAS
MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*
40,000/28,000
37,500/26,000
33,000/24,000
33,000/24,000
MANIFOLD PRESSURE (IN. WC)
3.5
10.0
3.5
10.0
MIN. INLET PRESSURE (IN. WC)
5.0
10.5
5.0
10.5
ORIFICE (DMS) 0-2,000 FT (0-610 M)*
1/8”
#49
#36
#51
*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M. ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS
CHIMNEY - USE 3" (76 MM) GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635.
THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE MANUFACTURER’S
INSTALLATION INSTRUCTIONS.
FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 1,000 FT (405 M).
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP
CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY.
KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING INSTRUCTIONS
ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY. DO NOT
OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S)
SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE
INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS
APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE
AGENCY OR GAS SUPPLIER.
DO NOT REMOVE OR COVER THIS LABEL
Part No. 580413-01 Rev. NC, 10/2011
IGN 11-6179
DATE OF MANUFACTURE / DATE DE FABRICATION
2011
2013
2014
2012
JAN
FEB MAR
APR MAY
JUN
JUL
AUG SEP
OCT
NOV DEC
MODEL
Note: Hearth protection to be min.
3/8” (10mm) thick non-combustible
or equivalent, with a k factor of .84.
A
D
B
E
C
CL
MANTEL
TRIM
MINIMUM FIREPLACE SIZES REQUIRED
....................
RDV40 IPI
RDV33 IPI
Front Opening ................................................................... 31.50” (800mm)
31.50” (800mm)
Height ................................................................................. 19.50” (495mm)
19.50” (495mm)
Rear Width ........................................................................ 19.00” (483mm)
19.00” (483mm)
Depth ................................................................................. 16.00” (406mm)
16.00” (406mm)
MINIMUM CLEARANCES TO COMBUSTIBLES
A = Top Facing to Bottom of Appliance ..................... 35.5" (902mm)
31.5" (800mm)
B = Side Facing or Side Wall to Center of Glass ...... 25.5" (648mm)
25.5" (648mm)
* C = 10.5” (267mm) Mantel to Bottom of Appliance . 43" (1092mm)
39" (991mm)
HEARTH PROTECTION
D = Vertical Distance from base of appliance 0" 2” 4” 0" 2” 4”
to Hearth Extension .......................................... (0mm) (51mm) (102mm) (0mm) (51mm) (102mm)
E = Minimum Horizontal Distance
14" 10” 0” 13" 10” 0”
from Front of Appliance .................................. (356mm) (254mm) (0mm) (330mm) (254mm) (0mm)
MANTEL
FACING
*See owner’s manual for additional mantel clearances and options.
FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
CONFORME AU STANDARD ANSI Z21.88; CERTIFIÉ AU STANDARD CSA 2.33 ET CGA 2.17.
CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI
NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA). CET APPAREIL DOIT ÊTRE INSTALLÉ
SELON LES DIRECTIVES D’INSTALLATION DU FABRICANT. POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE SOLIDE
SEULEMENT - DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE. CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS CONÇU POUR ÊTRE
UTILISÉ AVEC DES FILTRES À AIR.
CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE ET PEUT ÊTRE INSTALLÉ DANS
UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE PERMETTENT. VOIR LE MANUEL
D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES TYPES DE GAZ À
MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.
DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.
SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE CONFORMES
AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.
DANGER:
CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES
ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS LA PIÈCE.
GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES
INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT TEMPS. VOIR LES MANUELS
D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. SEUL LE PANNEAU VITRÉ FOURNI PAR LE MANUFACTURIER
PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. EN AUCUN CAS, L’APPAREIL NE PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE
BRISÉE. LE REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
AVERTISSEMENT: UNE INSTALLATION INADÉQUATE DE MÊME QU’UN AJUSTEMENT, UNE MODIFICATION, UNE RÉPARATION OU UN
ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. RÉFÉREZ-VOUS AU MANUEL
D’ENTRETIEN LIVRÉ AVEC CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE
DE SERVICE OU UN FOURNISSEUR DE GAZ.
IGN 11-6179
N’ENLEVEZ PAS OU NE COUVREZ PAS CETTE ÉTIQUETTE
No. pièce #580413-01 Rev. NC, 10/2011
MODÈLE
FABRIQUÉ PAR:
LENNOX HEARTH PRODUCTS
1502 14TH ST NW
AUBURN, WA., USA 98001
Le numéro de série est indiqué dans la
section anglophone de cette étiquette
SERIAL
NO.
4002589
CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT CETTE
ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.
La date de fabrication est indiquée dans la section anglophone de cette étiquette
Ravenna™ IPI
SPÉCIFICATIONS
Ravenna 40 IPI (RDV40 IPI)
Ravenna 33 IPI (RDV33 IPI)
GAZ NATUREL
GAZ PROPANE
GAZ NATUREL
GAZ PROPANE
ENTRÉE MAX/MIN BTU/HR 0-4500 pi (0-1370 M)*
40000/28000
37500/26000
33000/24000
33000/24000
PRESSION À LA SORTIE (IN. WC/C.E.)
3,5
10,0
3,5
10,0
PRESSION MINIMUM D’ENTRÉE DU GAZ (IN. WC/C.E.)
5,0
10,5
5,0
10,5
ORIFICE (DMS) 0-4500 pi (0-1370 M)*
1/8”
#49
#36
#51
*L’APPAREIL PRÉUSINÉ EST MUNI D’ÉQUIPEMENT POUR 0-2000 PIEDS (0-610 M). AU CANADA 0-4500 PIEDS (0-1370M).
SPÉCIFICATIONS ÉLECTRIQUE 120 VCA, 60 HZ, MOINS DE 2 AMPÈRES
CHEMINÉE - POUR LA SORTIE D’ÉVACUATION DES GAZ UTILISEZ UNE GAINE DE TUBAGE CERTIFIÉ SELON UL1777 OU ULC S635.
CET APPAREIL DOIT ÊTRE RELIÉ À UN SYSTÈME D’ÉVACUATION TEL QUE SPÉCIFIÉ DANS LE MANUEL D’INSTALLATION DU
FABRICANT.
EN ALTITUDE, AU-DELÀ DE 2000 PI/610 M, (AU CANADA 0-4500 PI/0-1370M) LA CAPACITÉ ÉNERGÉTIQUE DE L’APPAREIL DIMINUE DE
QUATRE (4)% POUR CHAQUE 1000 PI (405 M).
SI LE MODÈLE RDV33 IPI EST CONVERTI COMME MODÈLE RDV40 IPI, ASSUREZ VOUS QUE LES
DÉGAGEMENT AUX COMBUSTIBLES SONT RESPECTER SELON LE MODÈLE RDV40 IPI.
DÉGAGEMENTS MINIMUMS
Note: Extension d’âtre fabriqué avec
3/8” (10mm) minimum de matériaux
non-combustible ou équivalent
possédant un facteur k de 0.84.
A
D
B
E
C
CL
DIMENSIONS MINIMUMS DE FOYER REQUISES
.......
RDV40 IPI
RDV33 IPI
Ouverture avant ................................................................ 31.50” (800mm)
31.50” (800mm)
Hauteur .............................................................................. 19.50” (495mm)
19.50” (495mm)
Largeur arrière ................................................................. 19.00” (483mm)
19.00” (483mm)
Profondeur ....................................................................... 16.00” (406mm)
16.00” (406mm)
DÉGAGEMENTS AUX COMBUSTIBLES
A = Du bas de l’appareil au dessous de
la finition supérieure .............................................. 35.5" (902mm)
31.5" (800mm)
B = Du centre de la vitre à la finition latérale ............. 25.5" (648mm)
25.5" (648mm)
* C =
10.5” (267mm) manteau de foyer à partir
de la base
................................................................ 43" (1092mm)
39" (991mm)
PROTECTION DU FOYER
D = Distance verticale de la base de
.................
0" 2” 4” 0" 2” 4”
de l’appareil à l’extension d’âtre .................... (0mm) (51mm) (102mm) (0mm) (51mm) (102mm)
E = Extension d’âtre min. à l’avant
....................
14" 10” 0” 13" 10” 0”
de l’appareil......................................................... (356mm) (254mm) (0mm) (330mm) (254mm) (0mm)
MANTEAU
DE FOYER
PIÉCE DE
FINITION
*Voir le manuel d’entretien pour les informatinos supplémentaires reliées aux distances à respecter pour le manteau de foyer.
2012 2013 2014 2015