NGP Keypad Installation Guide
revision 1.007 —
47
4. Siren plus all other loads must never exceed 1.0 A.
5. System shall be connected to a Listed smoke detector rated to operate over the range of 11.0 to
12.3 VDC. The last detector on the initiating circuit shall be a Listed ESL Model 449CTE with built in
end of line relay. The circuit shall also be terminated with a Model 166 6841 end of line resistor.
11.8
Household Burglar Alarm
1. Refer to Grade A local burglar alarm above for maximum standby and loading conditions.
2. Maximum entrance delay time shall not exceed 45 seconds.
3. System shall employ a Listed-sounding device rated to operate over the range of 11.0 to 12.3 VDC.
4. All zones shall be programmed to be supervised with a 2.2 kilo Ohm end of line resistor.
5. The system shall be housed in the Model 6801 enclosure.