4
460989001B
CPU status LED D45 possible module error conditions for LED Normal and
Series 2 modes:
Mounting
The SDC can be mounted in the LNL-AL400ULX or LNL-AL600ULX-
4CB6 and the LNL-CTX or LNL-CTX6 enclosure using the Universal
Mounting Plate (UMP) LNL-CONV-U2. The universal mounting plate can
hold up to two (2) LNL-1300-U modules.
Mounting the SDC in the LNL-AL400ULX and LNL-CTX
Mounting the SDC in the LNL-AL600ULX-4CB6 or LNL-CTX6
Error condition
Flashing
pattern
Description
No valid
application
firmware
3 Red,
2 Green
The module is not operational.
Firmware must be loaded using a
console, e.g. HyperTerminal with
Xmodem.
Boot loader waiting
on firmware file
3 Red,
1 Green
Console boot loader is waiting on
start of firmware file.
Boot loader loading
firmware file
2 Red,
2 Green
Console boot loader is loading a
firmware file.
Invalid EFL file
1 Red,
2 Green
The EFL specified to be loaded
using the console loader is not a
valid EFL file.
Invalid Xmodem
packet
1 Red,
1 Green
The console loader received an
invalid Xmodem packet and
terminated the firmware
download operation.
Invalid Application
firmware for
module CPU
3 Red,
0 Green
The module is not operational.
Application firmware loaded on
the module will not run properly.
Requires new firmware be loaded
using the console boot loader or
the module must be returned for
repair.
Invalid Boot
firmware for
module CPU
2 Red,
3 Green
The module is not operational.
Boot loader firmware loaded on
the module will not run properly.
The module must be returned for
repair.
Firmware update
failed
1 Red,
3 Green
Firmware update operation was
unsuccessful. Retry and if it fails
continuously, load a different
firmware file.
No valid primary
firmware copy
3 Green,
2 Red
The firmware flash contains 2
copies of the application
firmware. The primary copy is
not valid so the backup copy will
be loaded into the primary copy
and executed.
No valid backup
firmware copy
3 Green,
1 Red
The firmware flash contains 2
copies of the application
firmware. The backup copy is not
valid so the primary copy will be
loaded into the backup copy.
No valid
manufacturing
parameters
3 Green,
0 Red
The manufacturing parameters
which include the serial number,
etc. are invalid. The module must