background image

2

460989001B 

Setting DIP Switches

SDC dip switches

Communication Baud Rate (SW1)

Configure the baud rate using SW1 switches 1-4. (Switch 5 is used for LED 
control. Switches 6-8 are not used.)

Note:

If you are not using OSDP readers, SW1 switch 3 & 4 do not 
need to be set as indicated here.

LED Mode

SW1 switch 5 is used for LED control. It is read at boot time. If you make a 
change to this setting, be sure to restart.

Device Address (SW2)

Configure the board address using SW2. (Switches 6-8 are not used.)

Baud rate

SW1 switch for 
host

SW1 switch for 
OSDP readers 
(Aux ports)

1:

2:

3:

4:

2400 bps

off

off

off

off

9600 bps

ON

off

ON

off

19200 bps

off

ON

off

ON

38400 bps

ON

ON

ON

ON

SW1 Switch 5

State

ON

LEDs behave as the Access (LNL) series module.

off

LED behavior is in Normal Mode

Address

SW2 switch

5:

4:

3:

2:

1:

0

off

off

off

off

off

1

off

off

off

off

ON

2

off

off

off

ON

off

3

off

off

off

ON

ON

4

off

off

ON

off

off

5

off

off

ON

off

ON

6

off

off

ON

ON

off

7

off

off

ON

ON

ON

8

off

ON

off

off

off

9

off

ON

off

off

ON

10

off

ON

off

ON

off

11

off

ON

off

ON

ON

12

off

ON

ON

off

off

13

off

ON

ON

off

ON

14

off

ON

ON

ON

off

15

off

ON

ON

ON

ON

16

ON

off

off

off

off

17

ON

off

off

off

ON

18

ON

off

off

ON

off

19

ON

off

off

ON

ON

20

ON

off

ON

off

off

21

ON

off

ON

off

ON

22

ON

off

ON

ON

off

23

ON

off

ON

ON

ON

24

ON

ON

off

off

off

25

ON

ON

off

off

ON

26

ON

ON

off

ON

off

27

ON

ON

off

ON

ON

28

ON

ON

ON

off

off

29

ON

ON

ON

off

ON

30

ON

ON

ON

ON

off

31

ON

ON

ON

ON

ON

Summary of Contents for LNL-1300-U

Page 1: ...es a 12 to 24 VDC power source SDC board Dimensions are in inches mm Package Contents LNL 1300 U board 1000 ohm resistors Installation To install the SDC perform the installation procedures described...

Page 2: ...bps off ON off ON 38400 bps ON ON ON ON SW1 Switch 5 State ON LEDs behave as the Access LNL series module off LED behavior is in Normal Mode Address SW2 switch 5 4 3 2 1 0 off off off off off 1 off o...

Page 3: ...Ds LED Table for Series 2 LNL 1300 Mode When switch 5 is in the ON position the LEDs behave like the series 2 LNL 1300 LED Table for Normal Mode When SW1 switch 5 is in the off position the LEDs opera...

Page 4: ...modem packet and terminated the firmware download operation Invalid Application firmware for module CPU 3 Red 0 Green The module is not operational Application firmware loaded on the module will not r...

Page 5: ...hms maximum Belden 9841 West Penn or equivalent The drop cables to downstream devices should be kept as short as possible no longer than 10 feet The RS 485 communication is asynchronous half duplex us...

Page 6: ...ing LCD reader display control Wiring for OSDP readers Elevator Control OnGuard hardware is capable of supporting elevator control for up to 128 floors An elevator reader has an input output module th...

Page 7: ...uires a 12 to 24 VDC 10 power source for it input power Wire the power input with 18 AWG minimum twisted pair cable Power source wiring Notes Be sure to observe polarity Do not use an AC transformer t...

Page 8: ...o 95 at 85 C 185 F non condensing storage Certifications FCC Part 15 FCC compliance This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15...

Reviews: