TPG10 User Manual
Version GS 1607
10
Version GS 1607
Fig.19
WET
battery meant that it tests normal flooded types like Wet Low Maintenance (Lead [Pb] /
Calcium [Ca]) or Wet Standard (Lead [Pb] / Lead [Pb]) Batteries.
AGM FLAT
will tests Wet (MF) Maintenance Free (Calcium [Ca] / Calcium [Ca]), AGM flat
plates Batteries.
AGM SPIRAL
tests (Calcium [Ca] / Calcium [Ca]) spiral wound AGM Batteries.
EFB
will test Enhanced Flooded Battery or commonly known as Start / Stop Battery.
GEL
will test Gel Cell VRLA Batteries with units of measurement in Cold Cranking Amps.
8.
Before
selecting the ratings ‘CCA, SAE, EN, IEC, DIN, CA and JIS #’ from the menu, check
the battery specification value. This value can be checked on the battery labels as some of the
examples shown below:
9.
With the rating selection, the analyser screen will display as per Fig.20 below.
Fig.20
When rating JIS# (Japanese Industrial Standard) was selected, please refer to the conversion
chart provided with the package for the CCA ratings of the battery.
Refer to the battery model (example: 80D26L or NX110-5L) on the Cold Cranking Amps
(CCA), WET is 580 CCA and AGM is 630 CCA.