ITZ 2000-SBPR FLEX ULTRASTAB

Secondary current monitoring

The rack electronics incorporates a 0.1 Ω resistance in series with the measuring resistance for the monitoring of the secondary 

current.

A BNC connector located on the rear panel provides a low-precision voltage output ±1 V full-scale which indicates a secondary 

current flowing through the measuring resistance and the 0.1 Ω resistance.

The voltage on this connector is equal to.

As one example, if 

I

P

 is 2000 A and 

N

P

/

N

S

 is  

1 V/A

200

 , the voltage on this connector is 1 V.

Similarly, if 

I

P

 is −2000 A and 

N

P

/

N

S

 is 

1 V/A

200

, the voltage on this connector is −1 V.

As another example, if 

I

P

 is 62.5 A and 

N

P

/

N

S

 is 

1 V/A

12.5

, the voltage on this connector is 0.5 V.

Similarly, if 

I

P

 is −62.5 A and 

N

P

/

N

S

 is 

1 V/A

12.5

, the voltage on this connector is −0.5 V.

Delivery package

The LEM ITZ 2000-SBPR FLEX UL TRASTAB package contains by default:

 

19-inch rack-mount ITZ FLEX ULTRASTAB electronics

 

Transducer head

 

European (Schuko CEE 7/7) and US/Japanese mains cables, 2 m each (with three-pole IEC C13 female connector).

 

Short-plug for 4 mm banana terminals and 15-pin D-Sub short-plug for analog output connector 
(back panel of electronics rack)

Mandatory accessories

The 3 following accessories have to be separately ordered as per the table hereafter, otherwise the ITZ FLEX ULTRASTAB can 

not operate without them:

 

Transducer head cable (interconnecting cable between transducer head and electronics rack)

 

Analog output cable

 

Programming plug 25-pin D-Sub (for connector on the head)

ITZ mandatory accessories

Available material

Available length

Part number

Transducer HEAD cable

Non-Halogeneous 

Non-Halogeneous 

Non-Halogeneous 

Halogeneous 

Halogeneous 

Halogeneous 

Halogeneous 

Halogeneous

10 m 

20 m 

30 m 

10 m 

15 m 

20 m 

25 m 

30 m

71.16.13.001.0 

71.16.17.001.0 

71.16.20.001.0

 

71.16.13.000.0 

71.16.15.000.0 

71.16.17.000.0 

71.16.19.000.0 

71.16.20.000.0

Analog output cable

Non-Halogeneous

1.5 m

71.17.E7.001.0

Programming plug 25-pin D-Sub

ITZ-PR 2000 A - 2000 A 

ITZ-PR 2000 A - 1875 A 

ITZ-PR 2000 A - 375 A 

ITZ-PR 2000 A - 125 A 

71.98.69.000.0

 

71.98.F8.000.0

 

71.98.E8.000.0

 

71.99.23.000.0

* Other values might be possible upon request to LEM.

S

P

S

P

(V)

/

 (V/A)

 (A) (Volt)

10

10

U

N

N

I

=

=

Summary of Contents for ITZ 2000-SBPR FLEX ULTRASTAB

Page 1: ...lock port on 9 pin D sub male output connector Secondary current monitoring on BNC connector 4 mm banana sockets for secondary current output Full featured indicator panel Advantages Very high accurac...

Page 2: ...ce required cleaning by dry compressed air is authorized This transducer is a build in device whose hazardous live parts must be inaccessible after installation This transducer must be mounted in a su...

Page 3: ...degree 2 Rated insulation RMS voltage reinforced insulation UNm V 1250 IEC 61010 1 conditions over voltage cat III pollution degree 2 RMS voltage for AC insulation test 50 60 Hz 1 min Ud kV 10 8 Impu...

Page 4: ...230 V RMS PC W VA 48 104 Average Peak RMS noise current 0 10 Hz 4 Ino ppm 0 1 RMS noise current 0 10 kHz 4 2 RMS noise current 0 100 kHz 4 60 Re injected RMS noise on primary bus bar 0 100 kHz V 10 Te...

Page 5: ...o improve them LEM International SA Route du Nant d Avril 152 1217 Meyrin www lem com ITZ 2000 SBPR FLEX ULTRASTAB Typical power consumption 0 10 20 30 40 50 60 2500 2000 1500 1000 500 0 500 1000 1500...

Page 6: ...lit when the transducer head saturates due to excessive primary current 600 A 24000 A yellow LED These LEDs are lit when a transducer head with the corresponding full scale range is connected to the r...

Page 7: ...Status Interlock signal outputs 9 pin D Sub male UNC 4 40 screw lock 8 Option A B These positions are for future expansion or customization not used 2 8 3 1 7 6 5 4 LEM International SA Route du Nant...

Page 8: ...esent on the port each having two dedicated floating pins in the SUBD9 Male connector Collector C and Emitter E Status Interlock port wiring Depending on how each signal is wired it can be Active Low...

Page 9: ...sducer head is not saturated High IP UC The primary current is higher than 105 of nominal full scale output 0 2 V The primary current is lower than 105 of nominal full scale output ACTIVE UC The prima...

Page 10: ...ed off When the rack electronics temperature cools to approximately 60 C the measuring circuit is automatically re enabled and the status LED is again lit Over current protection Electrical specificat...

Page 11: ...ansducer head description Connect the transducer head to the electronics rack using the supplied transducer head cable and mount the programming plug in the 25 pin D Sub connector on the transducer he...

Page 12: ...gh Out 6 Ground 7 US Low Sense 8 US Low Out 9 Current out 10 Current out 11 Current out 12 US High Sense 13 US High Out 14 US Low Sense 15 US Low Out Connect both pins 1 and 9 pins 2 and 10 pins 3 and...

Page 13: ...mount ITZ FLEX ULTRASTAB electronics Transducer head European Schuko CEE 7 7 and US Japanese mains cables 2 m each with three pole IEC C13 female connector Short plug for 4 mm banana terminals and 15...

Page 14: ...nt d Avril 152 1217 Meyrin www lem com ITZ 2000 SBPR FLEX ULTRASTAB Optional Calibration can be separately ordered as per the table hereafter Calibration with certificate in ISO 17025 certificated lab...

Page 15: ...odifications on its transducers in order to improve them LEM International SA Route du Nant d Avril 152 1217 Meyrin www lem com ITZ 2000 SBPR FLEX ULTRASTAB Dimensions Rack electronics in mm general t...

Reviews: